| Plan Review Stops For Permit 18110484 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
N |
Date |
2018-12-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-10 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-10 |
Time |
14:40 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-01-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-01-24 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-01-24 |
Time |
16:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-12-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-12-19 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-12-19 |
Time |
14:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-12-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-12-10 |
Time |
18:39 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-12-10 |
Time |
18:39 |
Sent To |
|
|
| Notes |
| 2018-12-10 18:40:50 | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | | NFPA 70 2011 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | NEED CUT SHEETS FOR POLE SHOWING WIND LOADS. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2018-11-21 |
|
|
Cont ID |
|
| Sent By |
MGONZALE |
Date |
2018-11-21 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2018-11-21 |
Time |
|
Sent To |
B |
|
| Notes |
| 2018-11-21 08:53:27 | NO OBJECTION. | | | | | | 1 CALL FOR LOCATES | | | 2. CONTACT CITY UTILITI CONSTRUCTION COORDINATOR WHEN | | | INSTALL BEGINS. | | | 3. LOCATE CITY IRRIGATION TRUNK LINES. (561) 822-2222 | | | | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-01-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-01-24 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-12-31 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2019-01-02 13:39:03 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-12-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-12-10 |
Time |
18:40 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-11-13 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2018-12-08 13:27:53 | 12/8 TO JD DESK / S.HILL | | | | | | | | 2018-11-20 11:16:08 | THIS PERMTI NEEDS TO BE ROUTED TO VLADIMIR JEANNOT IN | | | THE ENGINEERING DEPARTMENT. | | 2018-11-14 12:54:31 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-01-23 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2019-01-23 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2019-01-23 |
Time |
11:20 |
Sent To |
E |
|
| Notes |
| 2019-01-23 14:02:51 | PROVISO:PLEASE VERIFY THE LUMINAIRE SPEC EXACTLY | | | MATCHES CTITY'S SPEC IN THE WEB SITE. (SS55-007)-35W32L | | | ED4K-&-GL-LE3-UNNV-DMG-SFOK-RCD7-TN3-COLTX | | | POLE HEIGHT SHALL MATCH EXISTING POLE HEIGHT ON | | | QUADRILLE BLVD. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-11-20 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2018-11-20 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2018-11-15 |
Time |
16:30 |
Sent To |
ENG |
|
| Notes |
| 2018-11-20 11:14:13 | 1. PLEASE PROVIDE DETAILED INFORMATION FOR THE NEW LOAD | | | CENTER AT THE ALLEY TO CONFIRM THE PROPOSED BOX WILL | | | NOT BLOCK THE ALLEY RIGHT OF WAY. IS A NEW LOAD CENTER | | | NECESSARY? PREVIOUS LIGHTLING EXISTED IN THE AREA. | | | 2. PLEASE PROVIDE A CUT SHEET FOR THE LIGHT FIXTURE AND | | | POLE TO CONFIRM IT MATCHES WITH EXISTING POLE AND | | | FIXTURE ON THE WEST SIDE OF QUADRILLE BLVD. | | | 3. PLEASE STUDY THE EXACT LOCATION OF PROPOSED LIGHT | | | FIXTURES AS SOME APPEAR TO BE LOCATED IN THE MIDDLE OF | | | TEH SIDEWALK (NE CUADRANT). | | | 4. THE PROPOSED FIXTURES ON FERN STREET EAST OF | | | QUADRILLE MAY BE BETTER LOCATED ALIGNED WITH THE | | | STREETSCAPE ON THE ZONE ADJACENT TO THE CURB. PLEASE | | | STUDY FOR VIABILITY. | | | 5. DRAWINGS INDICATE A NEW FIXTURE WEST OF THE FEC | | | CROSSING. IT MAY BE BETTER TO RUN THE LIGHT FROM THE | | | WEST SIDE SO NO CROSSIGN UNDER THE FEC IS NECESSARY, | | | AND THE CITY DOES NOT INCUR IN ANY FEES FOR THE USE OF | | | THE FEC ROW. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439. | | | | | 2018-11-15 16:31:07 | ROUTED TO EL |
|
|