Plan Review Details - Permit 18110421
| Plan Review Stops For Permit 18110421 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-01-08 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-01-08 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2019-01-08 |
Time |
08:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-11-21 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2018-11-21 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-11-21 |
Time |
16:08 |
Sent To |
E |
|
| Notes |
| 2018-11-29 07:39:57 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PLEASE PROVIDE ORIGINAL SIGNED AND SEAL DOCUMENTS. | | | | | | THE PLANS SUBMITTED APPEAR TO BE A GOOD COLOR COPY. AN | | | ORIGINAL "WET SIGNATURE" IS REQUIRED, SEE BELOW. | | | | | | ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR OTHER | | | DOCUMENTS WHICH MUST BE SIGNED, DATED AND SEALED IN | | | ACCORDANCE WITH THE PROVISIONS OF FLORIDA STATUTES ? | | | 471.025, AND RULE 61G15-23.001, F.A.C. MAY BE | | | PHYSICALLY SIGNED, DATED AND SEALED AS PROVIDED HEREIN | | | BY THE PROFESSIONAL ENGINEER IN RESPONSIBLE CHARGE. | | | (1) THE LICENSEE SHALL SIGN BY HAND AN ORIGINAL OF THE | | | LICENSEE?S SIGNATURE ON EACH PAGE REQUIRED TO BE | | | SEALED. A SCANNED, FACSIMILE, DIGITALLY CREATED OR | | | COPIED IMAGE OF THE LICENSEE?S SIGNATURE SHALL NOT BE | | | USED. | | | (2) THE LICENSEE MUST THEN USE A WET SEAL, A DIGITALLY | | | CREATED SEAL, OR AN EMBOSSING SEAL PLACED PARTIALLY | | | OVERLAPPING THE LICENSEE?S SIGNATURE ON EACH PAGE | | | REQUIRED TO BE SEALED. THE PLACEMENT OF THE SEAL SHALL | | | NOT RENDER THE SIGNATURE ILLEGIBLE. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-01-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-01-02 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-01-02 |
Time |
15:33 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-11-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-11-27 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-11-27 |
Time |
15:50 |
Sent To |
I |
|
| Notes |
| 2018-11-27 15:56:28 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | VALUE TO LOW, PLEASE PROVIDE A SIGNED CONTRACT FOR WORK | | | INVOLVED. | | | | | | VLAUE SHOULD INCLUDE ALL MATERIALS CONTRACTOR OR | | | CUSTOMER SUPPLIED | | | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-01-08 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-01-08 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
jduprey |
Date |
2018-12-19 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2018-12-20 11:45:23 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-11-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-11-27 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-11-09 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2018-11-13 13:37:30 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-12-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-12-28 |
Time |
09:53 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-11-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-11-19 |
Time |
10:45 |
Sent To |
B |
|
| Notes |
| 2018-11-19 10:46:38 | PROVIDE DIMENSIONS (LENGTH, WIDTH) AND CALCULATE TOTAL | | | SQUARE FOOTAGE OF ALL PROPOSED SIGNS. PROVIDE DIMENSION | | | FOR MONUMENT SIGN HEIGHT | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] | | 2018-11-15 14:37:09 | ROUTED TO PG |
|
|
|