Plan Review Details - Permit 18110160
Plan Review Stops For Permit 18110160
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-12-31 Cont ID  
Sent By cthroop Date 2018-12-31 Time 15:23 Rev Time 0.00
Received By cthroop Date 2018-12-31 Time 14:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-12-17 Cont ID  
Sent By cthroop Date 2018-12-14 Time 16:06 Rev Time 0.00
Received By cthroop Date 2018-12-14 Time 15:18 Sent To  
Notes
2018-12-14 16:35:37WINDOWS AND DOORS ON PERMIT 18101036. CRAWL SPACE TO
 KITCHEN ISLAND. CT

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-12-28 Cont ID  
Sent By jleahy Date 2018-12-28 Time 15:44 Rev Time 0.00
Received By jleahy Date 2018-12-28 Time 15:44 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-12-14 Cont ID  
Sent By jleahy Date 2018-12-14 Time 14:55 Rev Time 0.00
Received By jleahy Date 2018-12-14 Time 13:50 Sent To  
Notes
2018-12-14 14:54:14FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NO SMOKE ALARMS, NO CO ALARMS SHOWN FBC R314, FBC R315
 PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED PER
 CODE. FBC R314.3, 315.1; FBC 107.2.1
  
 OUTLET SPACING MISSING IN SEVERAL AREAS
  
 E3901.2.1 SPACING. RECEPTACLES SHALL BE INSTALLED SO
 THAT NO POINT MEASURED HORIZONTALLY ALONG THE FLOOR
 LINE OF ANY WALL SPACE IS MORE THAN 6 FEET (1829 MM),
 FROM A RECEPTACLE OUTLET. [210.52(A)(1)]
  
 E3901.2.2 WALL SPACE.
 AS USED IN THIS SECTION, A WALL SPACE SHALL INCLUDE THE
 FOLLOWING: [210.52(A)(2)]
 1. 1.ANY SPACE THAT IS 2 FEET (610 MM) OR MORE IN
 WIDTH, INCLUDING SPACE MEASURED AROUND CORNERS, AND
 THAT IS UNBROKEN ALONG THE FLOOR LINE BY DOORWAYS AND
 SIMILAR OPENINGS, FIREPLACES, AND FIXED CABINETS.
 2. 2.THE SPACE OCCUPIED BY FIXED PANELS IN EXTERIOR
 WALLS, EXCLUDING SLIDING PANELS.
 3. 3.THE SPACE CREATED BY FIXED ROOM DIVIDERS SUCH AS
 RAILINGS AND FREESTANDING BAR-TYPE COUNTERS
  
 PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH
 CODE. NEC 210.8, 210.12, 215.5, 408.4; FBC RE3706.2,
 RE3902
  
 E3902.16 ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION.
 BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15-
 AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY
 ROOMS, DINING ROOMS,
 LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS,
 SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS,
 LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS SHALL BE
 PROTECTED BY ANY OF THE FOLLOWING: [210.12(A)]
  
 E3902.9 LAUNDRY AREAS. 125-VOLT, SINGLE-PHASE, 15- AND
 20-AMPERE RECEPTACLES INSTALLED IN LAUNDRY AREAS SHALL
 HAVE GROUND-FAULT CIRCUIT INTERRUPTER PROTECTION FOR
 PERSONNEL. [210.8(A)(9)]
  
 E3902.10 KITCHEN DISHWASHER BRANCH CIRCUIT.
 GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION SHALL BE
 PROVIDED FOR OUTLETS THAT SUPPLY DISHWASHERS IN
 DWELLING UNIT LOCATIONS. [210.8(D)]
  
 OUTLETS MISSING ON FRONT AND BACK OF BUILDING
  
 E3901.7 OUTDOOR OUTLETS.
 NOT LESS THAN ONE RECEPTACLE OUTLET THAT IS READILY
 ACCESSIBLE FROM GRADE LEVEL AND LOCATED NOT MORE THAN 6
 FEET, 6 INCHES (1981 MM) ABOVE GRADE, SHALL BE
 INSTALLED OUTDOORS AT THE FRONT AND BACK
 OF EACH DWELLING UNIT HAVING DIRECT ACCESS TO GRADE
 LEVEL. BALCONIES, DECKS, AND PORCHES THAT ARE
 ACCESSIBLE FROM INSIDE OF THE DWELLING UNIT SHALL HAVE
 AT LEAST ONE RECEPTACLE OUTLET INSTALLED WITHIN
 THE PERIMETER OF THE BALCONY, DECK, OR PORCH. THE
 RECEPTACLE SHALL BE LOCATED NOT MORE THAN 6 FEET, 6
 INCHES (1981 MM) ABOVE THE BALCONY, DECK, OR PORCH
 SURFACE. [210.52(E)]
  
 IS THERE AN AC SYSTEM?????

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2018-12-31 Cont ID  
Sent By cthroop Date 2018-12-31 Time 15:23 Rev Time 0.00
Received By cthroop Date 2018-12-31 Time 14:48 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2018-12-18 Cont ID  
Sent By jesmith Date 2018-12-18 Time 10:36 Rev Time 0.00
Received By jesmith Date 2018-12-18 Time 10:36 Sent To  
Notes
2018-12-18 10:36:39CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 GAS COMMEMTS: DENIED
  
 1. PROVIDE SIZING TABLE COMPLIANT WITH 2017 FBC FG CODE
 6TH EDITION, NOT 2014 5TH EDITION PER WPB FBC 107.2.1
 2. INDICATE THE DELIVERY PRESSURE (PSI) OF THE SYSTEM
 ON THE PLAN PER FBC RES G2413.2, G2413.4.3.
 3. SHOW TYPE OF MATERIAL FOR ABOVE GROUND PIPING AND
 INDICATE ON THE RISER DIAGRAM TRANSITION FITTINGS FOR
 PE TO ABOVE GROUND PIPING PER WPB FBC 107.2.1
  
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID".
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-01-03 Cont ID  
Sent By hmoser Date 2019-01-03 Time 10:45 Rev Time 0.00
Received By hmoser Date 2019-01-02 Time 14:45 Sent To M
Notes
2019-01-02 14:45:58TO HMOSER

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-12-31 Cont ID  
Sent By cthroop Date 2018-12-31 Time 15:23 Rev Time 0.00
Received By cthroop Date 2018-12-28 Time 15:19 Sent To  
Notes
2018-12-28 15:26:23TO JLEAHY DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-12-19 Cont ID  
Sent By hmoser Date 2018-12-19 Time 10:02 Rev Time 0.00
Received By hmoser Date 2018-11-05 Time 14:48 Sent To  
Notes
2018-12-14 12:22:16R20
2018-11-06 14:48:45LIBRARY

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2019-01-03 Cont ID  
Sent By hmoser Date 2019-01-03 Time 10:45 Rev Time 0.00
Received By hmoser Date 2019-01-03 Time 10:24 Sent To I
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2018-12-31 Cont ID  
Sent By hmoser Date 2018-12-31 Time 11:37 Rev Time 0.00
Received By hmoser Date 2018-12-31 Time 11:37 Sent To P
Notes
2018-12-31 11:37:29PLAN DENIED
 1) PROVIDE EQUIPMENT SCHEDULE ON PLAN. PER SECTION 107
 WEST PALM BEACH AMENDMENTS 2017
 2) REFER TO SECTION 107.2.1.3 QUALITY OF BUILDING PLANS
 WEST PALM BEACH AMENDMENTS 2017
 3) PROVIDE EQUIPMENT SCHEDULE ON PLANS
 SECTION 107 WEST PALM BEACH AMENDMENTS 2017
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-12-19 Cont ID  
Sent By hmoser Date 2018-12-19 Time 10:01 Rev Time 0.00
Received By hmoser Date 2018-12-19 Time 09:39 Sent To I
Notes
2018-12-27 11:46:10MET WITH OWNER AND EXPALINED THIS IS FOR DOWNSTIRS
 ONLY.
2018-12-19 10:01:38PLAN DENIED
 IT IS WRITTEN ON THE PLAN A/C IS UNDER ELECTRICAL PLAN
 WHAT DOES THAT MEAN.
 REFER TO SECTION 107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS. 2017 CITY OF WEST PALM BEACH AMENDMENTS.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-12-31 Cont ID  
Sent By cthroop Date 2018-12-31 Time 15:23 Rev Time 0.00
Received By cthroop Date 2018-12-31 Time 14:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-12-18 Cont ID  
Sent By jesmith Date 2018-12-18 Time 10:47 Rev Time 0.00
Received By jesmith Date 2018-12-18 Time 10:47 Sent To  
Notes
2018-12-18 10:47:38CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 PLUMBING COMMENTS COMMEMTS: DENIED
  
 1. RE: REMODELED 1ST FLOOR BATHROOM WITH ADDED SHOWER
 A. PROVIDE RISER DIAGRAM IDICATING HOW THE SHOWER WILL
 BE VENTED IN ACCORDANCE WITH THE REQUIREMENTS OF FBC
 RES P3108.1 AND IF APPLICABLE P3108.1 PER WPB FBC
 107.2.1
  
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID".
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  