Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-11-15 Cont ID  
Sent By dbattles Date 2018-11-15 Time 10:33 Rev Time 0.00
Received By dbattles Date 2018-11-15 Time 10:33 Sent To  
Notes
2018-11-15 10:35:06PROVISO:
 [FBC R905.2.2] [FBC R905.1.1]FOR ROOF SLOPES FROM TWO
 UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) AND LESS
 THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL (4:12),
 DOUBLE UNDERLAYMENT APPLICATION IS REQUIRED.
 SLOPE IS INDICATED AS 3.5:12, THIS WOULD REQUIRE DOUBLE
 LAYER OF UNDERLAYMENT.