Plan Review Details - Permit 18110073
Plan Review Stops For Permit 18110073
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-11-14 Cont ID  
Sent By cthroop Date 2018-11-14 Time 10:55 Rev Time 0.00
Received By cthroop Date 2018-11-14 Time 10:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-11-14 Cont ID  
Sent By jpearson Date 2018-11-14 Time 08:18 Rev Time 0.00
Received By jpearson Date 2018-11-14 Time 08:01 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-12-03 Cont ID  
Sent By pleduc Date 2018-12-03 Time   Rev Time 0.00
Received By pleduc Date 2018-12-03 Time 11:03 Sent To M
Notes
2018-12-03 11:10:28REGARDING FIRE'S PREVIOUS COMMENTS, FS SHOP DRAWINGS
 WERE SUBMITTED AND APPROVED, PROVISO COMMENTS ADDED TO
 APPLICABLE PLAN SHEETS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2018-11-07 Cont ID  
Sent By pleduc Date 2018-11-07 Time   Rev Time 0.00
Received By pleduc Date 2018-11-07 Time 14:07 Sent To  
Notes
2018-11-07 14:28:16THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
  
 1) SHEET A 1 & L 2 - THERE ARE INDICATIONS THAT FIRE
 SPRINKLER PROTECTION IS EXISTING AND NO CHANGE IS
 REQUIRED.
  
 ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR
 SPRINKLER SYSTEM FOR CODE COVERAGE AND COMPLIANCE BY
 CERTIFIED LIFE SAFETY CONTRACTORS.
  
  
 PER THE FLORIDA FIRE PREVENTION CODE 6TH ED
  
 NFPA 1
  
 1.14 PLAN REVIEW.
 1.14.1 WHERE REQUIRED BY THE AHJ FOR NEW CONSTRUCTION,
 MODIFICATION, OR REHABILITATION, CONSTRUCTION DOCUMENTS
 AND SHOP
 DRAWINGS SHALL BE SUBMITTED, REVIEWED, AND APPROVED
 PRIOR TO THE
 START OF SUCH WORK AS PROVIDED IN SECTION 1.14.
  
 THOUGH SHOP DRAWINGS ARE NOT REQUIRED AT THIS TIME AND
 DUE TO THE DEFINITIVE STATEMENT NOTE OF NO FIRE
 SPRINKLER CHANGE REQUIRED, A NOTE OF ACKNOWLEDGEMENT TO
 HAVE THIS PROPOSED FLOOR PLAN REVIEWED VS THE EXISTING
 FIRE SPRINKLER HEADS IS REQUIRED ON THIS PLAN
 SUBMITTAL.
  
 SHOULD THE FIRE SPRINKLER HEAD REVIEW FIND NEW HEADS
 ARE REQUIRED, SHOP DRAWINGS SHALL BE SUBMITTED.
  
 PLEASE REMOVE THE SUBMITTED COMMENTS AND PROVIDE THE
 APPLICABLE NOTE FOR SHOP DRAWINGS IN A REVISION CLOUD.
  
  
  
 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP
 DRAWINGS AND BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
  
 3) THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
  
 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-12-04 Cont ID  
Sent By hmoser Date 2018-12-04 Time 11:48 Rev Time 0.00
Received By hmoser Date 2018-11-26 Time 12:57 Sent To  
Notes
2018-11-28 12:57:45RESUB ROUTED TO FIRE INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-11-14 Cont ID  
Sent By cthroop Date 2018-11-14 Time 10:55 Rev Time 0.00
Received By cthroop Date 2018-11-02 Time 12:50 Sent To  
Notes
2018-11-06 12:50:40B09

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-12-04 Cont ID  
Sent By hmoser Date 2018-12-04 Time 11:47 Rev Time 0.00
Received By hmoser Date 2018-12-03 Time 15:14 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-11-14 Cont ID  
Sent By ccole Date 2018-11-14 Time 09:40 Rev Time 0.00
Received By ccole Date 2018-11-14 Time 09:35 Sent To  
Notes
2018-11-14 10:00:361ST REVIEW FBC-2017 MECHANICAL
 PERMIT #18110073
 11/14/18
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M1: REFER TO SECTIONS 809.1 & 809.2 FBC-17
 EXISTING BUILDING CODE AND PROVIDE MINIMUM VENTILATION
 CALCULATIONS FOR ALL ROOMS AND SPACES PER TABLE
 403.3.1.1 FBC-17 MECHANICAL. PROVIDE A SCHEDULE THAT
 INDICATES THE REQUIRED AND PROVIDED CFMS OF OUTDOOR
 AIR.
  
 2) M1: PROVIDE THE SUPPLY CFMS AT EACH RELOCATED
 DIFFUSER- SECTION 603.1 FBC M.
  
 3) M1: CLARIFY THE SEQUENCE OF OPERATION FOR THE
 MOTORIZED DAMPERS ON THE RETURN DUCTS. PLEASE NOTE THAT
 AUTOMATIC DAMPERS ARE REQUIRED FOR O/A INTAKE DUCTS PER
 SECTION C403.2.4.3 FMC EC, HOWEVER THIS REQUIREMENT
 DOES NOT APPLY TO RETURN DUCTS.
  
 4) M1: THE 10" RETURN DUCT FROM THE CREW ROOM APPEARS
 TO BE TRANSFERRING AIR INTO THE CORRIDOR AS A MEANS OF
 RETUN TO THE AIR HANDLER, WHICH IS PROHIBITED PER
 SECTION 601.2 FBC M. PLEASE CONNECT THE DUCT DIRECTLY
 TO THE AIR HANDLER.
  
 5) M1: PLEASE BE ADVISED THAT DUCT SMOKE DECTORS ARE
 REQUIRED IN THE SUPPLY AIR SYSTEMS OF AIR HANDLER
 SUPPLY SYSTEMS WITH CAPACITIES GREATER THAN 2000 CFMS-
 SECTION 606.2.1 FBC M.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  