Plan Review Details - Permit 18101444
Plan Review Stops For Permit 18101444
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-12-06 Cont ID  
Sent By cthroop Date 2018-12-06 Time 07:34 Rev Time 0.00
Received By cthroop Date 2018-12-06 Time 07:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-11-13 Cont ID  
Sent By cthroop Date 2018-11-13 Time 11:21 Rev Time 0.00
Received By cthroop Date 2018-11-13 Time 11:20 Sent To E
Notes
2018-11-13 11:25:10BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 FBC 107.3.5.1.1(8) ? PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-CHAPTER 16
  
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-11-16 Cont ID  
Sent By ppetty Date 2018-11-16 Time 13:57 Rev Time 0.00
Received By ppetty Date 2018-11-16 Time 13:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-11-19 Cont ID  
Sent By cpuell Date 2018-11-19 Time 10:28 Rev Time 0.00
Received By cpuell Date 2018-10-31 Time 14:57 Sent To  
Notes
2018-11-01 14:57:18ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 2 Status P Date 2018-11-28 Cont ID  
Sent By mcruz Date 2018-11-28 Time 12:52 Rev Time 0.00
Received By mcruz Date 2018-11-28 Time 12:52 Sent To PC
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2018-11-02 Cont ID  
Sent By mcruz Date 2018-11-02 Time 11:14 Rev Time 0.00
Received By mcruz Date 2018-11-02 Time 10:56 Sent To B
Notes
2018-11-02 11:14:05ZONING REVIEW FAILED, DUE TO THE FOLLOWING:
  
 1) AS THE ALLOWABLE SQUARE FOOTAGE OF THE SIGN IS BASED
 ON THE SQUARE FOOTAGE OF THE BUILDING FACADE, PLEASE
 INDICATE THE HEIGHT AND WIDTH OF THE FACADE ON WHICH
 THE SIGN IS TO BE MOUNTED. IF LEASING A SPACE, PROVIDE
 HEIGHT AND WIDTH OF LEASED SPACE. THE HEIGHT WAS
 PROVIDED BUT NOT THE WIDTH OF THE LEASED SPACE.
  
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ
 ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: 561-822-1442
 E-MAIL: [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved