| Plan Review Stops For Permit 18101112 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-01-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-08 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-08 |
Time |
13:31 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-12-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-07 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-06 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2018-12-07 14:16:09 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. VALUE APPEARS LOW FOR PROPOSED SCOPE OF WORK. | | | YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE | | | OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. | | | | | | CITY OF WPB CHPT. 1 ? VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | 2. CHANGE BLDG. CLASSIFICATION ON PLAN PAGE F2-00 FROM | | | R-1 TO R-2. | | | 310.4 RESIDENTIAL GROUP R-2. | | | RESIDENTIAL GROUP R-2 OCCUPANCIES CONTAINING SLEEPING | | | UNITS OR MORE THAN TWO DWELLING UNITS WHERE THE | | | OCCUPANTS ARE PRIMARILY PERMANENT IN NATURE, INCLUDING. | | | | | | 3. FAIR HOUSING DESIGN MUST BE MAINTAINED THROUGHOUT | | | ALTERATION. | | | 3A. IDENTIFY WHICH BATHROOM WILL COMPLY WITH FAIR | | | HOUSING. | | | 3B. KITCHEN REMOVED IN UNIT 3907. ALTERATIONS MADE TO | | | KITCHEN IN UNIT 3908. PROVIDE DEMENSIONS OF ALTERED | | | FLOOR PLAN IN REMAINING KITCHEN. | | | | | | 4. SEPERATE PERMIT WILL BE REQUIRED FOR NEW FLOORING. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2019-01-23 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-01-23 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-01-23 |
Time |
13:56 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-01-18 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-01-18 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-01-18 |
Time |
15:49 |
Sent To |
P |
|
| Notes |
| 2019-01-18 15:49:44 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. ELECTRICAL SHEETS PROVIDED BY ELECTRICAL CONTRACTOR | | | CONFLICT WITH SHEETS PROVIDED BY DESIGN PROFESSIONAL. | | | CORRECT ANY DISCREPANCIES. SCOPE OF WORK ON ELECTRICAL | | | SHEETS VERSUS THE REFLECTED CEILING PLAN DOES NOT | | | APPEAR TO RECONCILE. PROVIDE CORRECTIONS AND PROVIDE | | | DETAIL SCOPE OF WORK. IF ELECTRICAL PANEL IS TO BE | | | REPLACED OR RELOCATED, SHOW LOCATION. WPB FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-01-10 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-01-10 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-01-10 |
Time |
11:18 |
Sent To |
I |
|
| Notes |
| 2019-01-10 11:17:56 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. ELECTRICAL SHEETS PROVIDED BY ELECTRICAL CONTRACTOR | | | CONFLICT WITH SHEETS PROVIDED BY DESIGN PROFESSIONAL. | | | CORRECT ANY DISCREPANCIES. SCOPE OF WORK ON ELECTRICAL | | | SHEETS VERSUS THE REFLECTED CEILING PLAN DOES NOT | | | APPEAR TO RECONCILE. PROVIDE CORRECTIONS AND PROVIDE | | | DETAIL SCOPE OF WORK. IF ELECTRICAL PANEL IS TO BE | | | REPLACED OR RELOCATED, SHOW LOCATION. WPB FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-11-05 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-11-05 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-11-05 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2019-01-10 11:19:18 | CHANGED STATUS TO FAIL BASED ON NEW SUBMISSION. SEE | | | NOTES FOR SECOND REVIEW. JP |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-01-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-01-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-01-04 |
Time |
10:44 |
Sent To |
B |
|
| Notes |
| 2019-01-04 10:45:12 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR | | | CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR | | | SPRINKLER SYSTEM FOR CODE COVERAGE AND COMPLIANCE BY | | | CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE | | | SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP | | | DRAWINGS AND BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | 3) THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-10-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-10-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-10-29 |
Time |
14:24 |
Sent To |
I |
|
| Notes |
| 2018-10-29 14:25:11 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR | | | CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR | | | SPRINKLER SYSTEM FOR CODE COVERAGE AND COMPLIANCE BY | | | CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE | | | SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP | | | DRAWINGS AND BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | 3) THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-01-22 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-01-22 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-01-22 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2019-01-16 15:44:41 | RESUB ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-01-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-01-02 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2019-01-03 13:36:36 | RESUB ROUTED TO FIRE INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-12-13 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-12-13 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-12-13 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2018-12-08 10:56:32 | 12/8 REMOVED FROM BOARD, ROUTED TO JES DESK | | | | | | | | 2018-10-26 12:39:38 | B13 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2018-12-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-07 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-07 |
Time |
11:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2018-11-06 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-11-06 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-11-06 |
Time |
13:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-01-22 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-01-22 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-01-22 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2019-01-22 09:03:49 | APPROVED | | | PROVISO | | | 1. PLUMBING SCOPE IS LIMITED TO DEMO NOTES 4 AND 7 ON | | | PLAN SHEET F2-01 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2018-12-13 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-12-13 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-12-13 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2018-12-13 09:59:09 | APPROVED | | | PROVISO | | | 1. PLUMBING SCOPE IS LIMITED TO DEMO NOTES 4 AND 7 ON | | | PLAN SHEET F2-01 | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | | | | 18101112 4850 RYNA GREENBAUM DR |
|
|