| Plan Review Stops For Permit 18101050 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2019-06-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-06-14 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-06-14 |
Time |
15:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-05-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-05-13 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-05-13 |
Time |
11:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-05-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-06 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-06 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2019-05-06 09:34:00 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC 2014, BUILDING | | | | | | COMMENT FROM PREVIOUS TWO REVIEWS: | | | | | | 5) NOT COMPLIED. SIGNED AND SEALED CALCULATIONS AS | | | REQUESTED WERE NOT PROVIDED. SUBMIT THE TEST REPORTS OF | | | THE FOAM FOR THE FLAME SPREAD AND SMOKE DEVELOPED (ASTM | | | E84 OR UL 723). PROVIDE DETAILS ON THE PLANS OF HOW THE | | | FOAM WILL BE ENCASED IN CONCRETE AS REQUIRED BY FBC | | | 603.1. | | | STRUCTURAL FOAM FILL IS SHOWN ON SHEET P2.2 BELOW THE | | | POOL. IT APPEARS THAT THIS FOAM WILL BE SUPPORTING THE | | | POOL. SUBMIT THE PRODUCT SPECIFICATIONS FOR THIS FOAM | | | WITH SIGNED AND SEALED ENGINEERED CALCULATIONS TO SHOW | | | THAT THE STRUCTURAL FOAM WILL SUPPORT THE FILLED POOL. | | | FBC 107.2.1.2 NOTE: FOAM IN TYPE I AND II BUILDINGS IS | | | REQUIRED TO BE ENCASED IN CONCRETE. FBC 603.1 | | | | | | 3RD REVIEW: | | | | | | THE RESPONSE LETTER FROM THE POOL CONTRACTOR STATES | | | THAT CALCULATIONS ARE ATTACHED. EXHIBIT A STRUCTURAL | | | FOAM CALC WAS NOT PREPARED BY AN ENGINEER, FS471. AS | | | DELEGATED ENGINEERING, THE CALCULATIONS SHOULD BE | | | PREPARED BY THE POOL ENGINEER AND REVIEWED BY | | | STRUCTURAL ENGINEER OF RECORD. | | | | | | THE FOAM SPECS STATE THAT AN ASTM TEST WILL BE DONE | | | UPON ACCEPTANCE OF THE ORDER. PLEASE PROVIDE. | | | | | | ***THIS PERMIT WILL BE ISSUED WITH PROVISO - THE | | | NANAWALL IS SHOWN AS A POOL BARRIER. THIS IS NOT A | | | COMPLIANT POOL BARRIER; ARCHITECT AND OWNER HAVE BEEN | | | ADVISED REGARDING THIS ISSUE*** | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-03-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2019-03-11 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2019-03-11 |
Time |
15:39 |
Sent To |
I |
|
| Notes |
| 2019-03-11 15:39:56 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) COMPLIED. | | | | | | 2) COMPLIED. | | | | | | 3) COMPLIED. | | | | | | 4) COMPLIED. | | | | | | 5) NOT COMPLIED. SIGNED AND SEALED CALCULATIONS AS | | | REQUESTED WERE NOT PROVIDED. SUBMIT THE TEST REPORTS OF | | | THE FOAM FOR THE FLAME SPREAD AND SMOKE DEVELOPED (ASTM | | | E84 OR UL 723). PROVIDE DETAILS ON THE PLANS OF HOW THE | | | FOAM WILL BE ENCASED IN CONCRETE AS REQUIRED BY FBC | | | 603.1. | | | STRUCTURAL FOAM FILL IS SHOWN ON SHEET P2.2 BELOW THE | | | POOL. IT APPEARS THAT THIS FOAM WILL BE SUPPORTING THE | | | POOL. SUBMIT THE PRODUCT SPECIFICATIONS FOR THIS FOAM | | | WITH SIGNED AND SEALED ENGINEERED CALCULATIONS TO SHOW | | | THAT THE STRUCTURAL FOAM WILL SUPPORT THE FILLED POOL. | | | FBC 107.2.1.2 NOTE: FOAM IN TYPE I AND II BUILDINGS IS | | | REQUIRED TO BE ENCASED IN CONCRETE. FBC 603.1 | | | | | | NOTE: WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-12-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-12-11 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-12-11 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2018-12-11 11:46:42 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | | APPLICATION. THE CONSTRUCTION DOCUMENTS SHALL BE | | | PREPARED BY A REGISTERED DESIGN PROFESSIONAL WHERE | | | REQUIRED BY CHAPTER 471, FLORIDA STATUTES & 61G15 | | | FLORIDA ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA | | | STATUTES & 61G1 FLORIDA ADMINISTRATIVE CODE. WHERE | | | SPECIAL CONDITIONS EXIST, THE BUILDING OFFICIAL IS | | | AUTHORIZED TO REQUIRE ADDITIONAL CONSTRUCTION DOCUMENTS | | | TO BE PREPARED BY A REGISTERED DESIGN PROFESSIONAL. | | | ELECTRONIC MEDIA DOCUMENTS SHALL BE SUBMITTED WHEN | | | REQUIRED BY THE BUILDING OFFICIAL, AND MAY REQUIRE ONLY | | | ONE SET OF SUBMITTALS. THE ELECTRONICALLY SUBMITTED | | | PLANS REQUIRE THE ENGINEER'S DIGITAL SIGNATURE. FAC | | | 61G15-23.003 | | | | | | 2) THE ELECTRICAL PLAN SHEET E1.0 THAT IS LISTED IN THE | | | TABLE OF CONTENTS ON SHEET P1.0 WAS NOT UPLOADED. WITH | | | THIS SUBMITTAL. FBC 107.2.1 | | | | | | 3) SHOW HOW COMPLIANCE WITH FBC 454.1.3.1.9 WILL BE | | | MET. ALL PUBLIC POOLS SHALL BE SURROUNDED BY A MINIMUM | | | 48 INCH (1219 MM) HIGH FENCE OR OTHER APPROVED | | | SUBSTANTIAL BARRIER. THE FENCE SHALL BE CONTINUOUS | | | AROUND THE PERIMETER OF THE POOL AREA THAT IS NOT | | | OTHERWISE BLOCKED OR OBSTRUCTED BY ADJACENT BUILDINGS | | | OR STRUCTURES AND SHALL ADJOIN WITH ITSELF OR ABUT TO | | | THE ADJACENT MEMBERS. ACCESS THROUGH THE BARRIER OR | | | FENCE FROM DWELLING UNITS, SUCH AS HOMES, APARTMENTS, | | | MOTEL ROOMS AND HOTEL ROOMS, SHALL BE THROUGH | | | SELF-CLOSING, SELF-LATCHING LOCKABLE GATES OF 48 INCH | | | (1219 MM) MINIMAL HEIGHT FROM THE FLOOR OR GROUND WITH | | | THE LATCH LOCATED A MINIMUM OF 54 INCHES (1372 MM) FROM | | | THE BOTTOM OF THE GATE OR AT LEAST 3 INCHES (76 MM) | | | BELOW THE TOP OF THE GATE ON THE POOL SIDE. IF THE | | | SELF-CLOSING, SELF-LATCHING GATE IS ALSO SELF-LOCKING | | | AND IS OPERATED BY A KEY LOCK, ELECTRONIC OPENER OR | | | INTEGRAL COMBINATION LOCK, THEN THE OPERABLE PARTS OF | | | SUCH LOCKS OR OPENERS SHALL BE 34 INCHES MINIMUM (864 | | | MM) AND 48 INCHES MAXIMUM (1219 MM) ABOVE THE FINISHED | | | FLOOR OR GROUND. DOORED ACCESS POINTS FROM PUBLIC ROOMS | | | SUCH AS LOBBIES OR CLUB HOUSES NEED NOT BE THROUGH | | | GATES IF THE DOOR(S) MEET THE SAME SELF-CLOSING, | | | SELF-LATCHING REQUIREMENTS AS A GATE. GATES SHALL OPEN | | | OUTWARD AWAY FROM THE POOL AREA. A LATCHED, LOCKABLE | | | GATE SHALL BE PLACED IN THE FENCE WITHIN 10 FEET (3048 | | | MM) OF THE CLOSEST POINT BETWEEN THE POOL AND THE | | | EQUIPMENT AREA FOR SERVICE ACCESS. | | | | | | 4) 454.1.2.3.5 RULES AND REGULATIONS SIGNAGE. ITEM #8 | | | WAS NOT INCLUDED ON YOUR SIGNAGE 8.IF THE POOL INCLUDES | | | A SUN SHELF, "WARNING: DROP OFF AT SUN SHELF EDGE IS | | | _X_ FEET DEEP" IN 4-INCH (102 MM) LETTERS. | | | | | | 5) STRUCTURAL FOAM FILL IS SHOWN ON SHEET P2.2 BELOW | | | THE POOL. IT APPEARS THAT THIS FOAM WILL BE SUPPORTING | | | THE POOL. SUBMIT THE PRODUCT SPECIFICATIONS FOR THIS | | | FOAM WITH SIGNED AND SEALED ENGINEERED CALCULATIONS TO | | | SHOW THAT THE STRUCTURAL FOAM WILL SUPPORT THE FILLED | | | POOL. FBC 107.2.1.2 NOTE: FOAM IN TYPE I AND II | | | BUILDINGS IS REQUIRED TO BE ENCASED IN CONCRETE. FBC | | | 603.1 | | | | | | NOTE: WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2019-07-10 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-07-10 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-07-10 |
Time |
08:10 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2019-06-12 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-06-12 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-06-12 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2019-06-12 10:17:26 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE LIGHT FIXTURE SCHEDULE FOR LIGHTING IN POOL | | | AND POOL AREA. SOME OF THE FIXTURES SPECIFIED ARE NOT | | | ON THE ORIGINAL LIGHT FIXTURE SCHEDULE. BE ADVISED THAT | | | FIXTURE RL2 IS SHOWN IN ORIGINAL LIGHT FIXTURE SCHEDULE | | | AS A 277 VOLT FIXTURE. SHEET E-104 SHOWS IT BEING FED | | | FROM A 120/208 VOLT PANEL. PROVIDE CLARIFICATION AND/OR | | | CORRECTION. WPB FBC 107.2.1 | | | 2. SHEET E-104 SHOWS FIXTURE RL2 LOCATED APPROXIMATELY | | | 54 INCHES FROM POOL. NO LIGHT FIXTURE SHALL BE | | | INSTALLED LOWER THAN 12 FEET WHEN WITHIN 5 FEET OF THE | | | POOL. PROVIDE CLARIFICATION AND/OR CORRECTION. NEC | | | 680.22(B)(1) | | | 3. SHEET P2.0 SHOWS ONLY FIXTURE TYPE FL1 IN THE | | | PLANTERS. SHEET E-104 SHOWS FL2 IN THE PLANTER, AND FL1 | | | SURROUNDING THE PLANTER. PROVIDE CLARIFICATION AND/OR | | | CORRECTION. WPB FBC 107.2.1 | | | 4. SHEET E-104 IN A BLOCK NOTE STATES THAT ALL CIRCUITS | | | WITHIN 5-10 FEET OF POOL SHALL BE PROTECTED BY A GFCI | | | BREAKER. THE PANEL SCHEDULES FOR THESE CIRCUITS DO NOT | | | REFLECT THIS REQUIREMENT. SOME OF THE PANEL SCHEDULES | | | FOR LIGHTING IN THE POOL AREA ARE NOT INCLUDED IN THIS | | | SUBMISSION. PROVIDE CORRECTION. WPB FBC 107.2.1; NEC | | | 680.22(B)(4) | | | 5. LIGHT FIXTURE B IS SHOWN IN SEVERAL LOCATIONS. WHAT | | | ARE THESE FIXTURES? SHOW COMPLIANCE WITH FBC 454.1.4.2 | | | FOR MINIMUM LIGHTING LEVELS, AND NEC 680.22 OR 680.23 | | | AS APPLICABLE FOR VOLTAGE/GFCI PROTECTION AS REQUIRED. | | | 6. SHEET P2.0 QUOTES THE REQUIREMENT FOR UNDERWATER | | | LIGHTING STATING THAT IT IS FROM THE 2017 FBC. THIS | | | CODE SECTION QUOTED, FBC 454.1.4.2.3, IS NOT THE | | | CURRENT CODE. PROVIDE CORRECTION. WPB FBC 107.2.1; FBC | | | 454.1.4 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-05-14 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-05-14 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2019-05-14 10:24:04 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. THE ONLY ELECTRICAL SHEETS PROVIDED ARE 2 SHEETS | | | WITH PANEL SCHEDULES. THESE SHEETS BOTH SHOW THE SAME | | | PANEL, PANEL PP1, WHICH IS A 3 PHASE PANEL FED FROM | | | PANEL K8L. HOWEVER, THE LOAD SPECIFIED ON THESE TWO | | | PANEL SCHEDULES IS DIFFERENT, AND NEITHER OF THEM MATCH | | | THE EQUIPMENT REQUIREMENTS/LOAD SHOWN ON SHEET P3.0. | | | ADDITIONALLY, THERE ARE NO DETAILS, WIRING DIAGRAMS, | | | FLOOR PLANS, ETC., THAT SHOW THE ELECTRICAL WIRING AND | | | MATERIALS, INCLUDING THE PREVIOUSLY REQUESTED RATING OF | | | ENCLOSURES IN THE ELECTRICAL ROOM PER NEC TABLE 110.28. | | | THEREFORE, A COMPLETE REVIEW IS NOT POSSIBLE AT THIS | | | TIME. PROVIDE ELECTRICAL PLAN FOR REVIEW. WPB FBC | | | 107.1, 107.2.1 | | | 2. PLEASE BE ADVISED THAT SOME OF THESE COMMENTS HAVE | | | NOT BEEN ADDRESSED FOR THREE REVIEWS. IF UPON THE NEXT | | | REVIEW, IF IT IS NECESSARY TO REJECT THE SUBMITTED PLAN | | | AGAIN FOR THE SAME REASONS, AN ADDITIONAL PLAN REVIEW | | | IS REQUIRED. FLORIDA STATUTES STATE: WITH RESPECT TO | | | EVALUATION OF DESIGN PROFESSIONALS DOCUMENTS, IF A | | | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO | | | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND | | | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY | | | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A | | | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN | | | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, | | | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. FS 553.80(2)(B) | | | THE ADDITIONAL FEE FOR THIS PROJECT WOULD BE $5,185.00 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-04-30 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-04-30 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2019-04-30 07:45:37 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. NO ELECTRICAL PLAN PROVIDED FOR REVIEW. PLANS | | | SUBMITTED IN THE DIGITAL FORMAT MUST INCLUDE ALL OF THE | | | PLAN SHEETS DIGITALLY. WE DO NOT HAVE A HYBRID SYSTEM | | | WHERE SOME PLANS ARE PAPER AND SOME ARE DIGITAL. | | | PROVIDE CORRECTION. WPB FBC 107.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-03-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-03-05 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-03-05 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2019-03-05 15:13:31 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED AND | | | SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. A | | | DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE WITH PROPER | | | THIRD PARTY VERIFICATION. PROVIDE CORRECTION. WPB FBC | | | 107.1; FS 471/481 (THE ONLY TWO ELECTRICAL SHEETS | | | SUPPLIED WERE NOT SIGNED/SEALED.) | | | 2. ON SHEET P1.0, TABLE OF CONTENTS, IT SHOWS SHEET | | | E1.0. THIS SHEET IS NOT INCLUDED IN SUBMISSION. PROVIDE | | | FOR REVIEW. WPB FBC 107.1, 107.2.1 (COMMENT RESPONSE | | | STATES THAT ELECTRICAL PLAN WILL BE PROVIDED BY | | | ENGINEER. THE ONLY TWO SHEETS PROVIDED WERE PANEL | | | SCHEDULES AND THEY WERE NOT SIGNED/SEALED.) | | | 3. PROVIDE ENCLOSURE FOR ELECTRICAL PANEL THAT MEETS | | | THE REQUIREMENTS OF NEC FOR EXPOSURE TO CORROSIVE | | | AGENTS. NEC TABLE 110.28 (NOT PROVIDED.) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-11-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-11-27 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-11-27 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2018-11-27 14:39:30 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED AND | | | SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. A | | | DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE. PROVIDE | | | CORRECTION. WPB FBC 107.1; FS 471/481 | | | 2. ON SHEET P1.0, TABLE OF CONTENTS, IT SHOWS SHEET | | | E1.0. THIS SHEET IS NOT INCLUDED IN SUBMISSION. PROVIDE | | | FOR REVIEW. WPB FBC 107.1, 107.2.1 | | | 3. PROVIDE ENCLOSURE FOR ELECTRICAL PANEL THAT MEETS | | | THE REQUIREMENTS OF NEC FOR EXPOSURE TO CORROSIVE | | | AGENTS. NEC TABLE 110.28 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2019-01-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-01-02 |
Time |
06:57 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-01-02 |
Time |
06:57 |
Sent To |
|
|
| Notes |
| 2019-01-02 06:58:55 | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT IS REQUIRED FOR A | | | CONTRACTOR TO PERFORM THE RELATED WORK. PROVIDE | | | COMPLETE PLANS THAT REFLECT THE ENTIRE SCOPE OF GAS | | | WORK TO BE DONE. WPB AMEND. TO FBC SEC.107.2.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-07-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-06-26 |
Time |
10:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2019-06-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-06-14 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-06-11 |
Time |
16:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-05-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-16 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-10 |
Time |
17:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-05-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-06 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-04-11 |
Time |
11:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-03-15 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-03-15 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-02-19 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2019-01-02 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-01-02 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-11-01 |
Time |
08:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2019-06-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-06-12 |
Time |
07:05 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-06-12 |
Time |
07:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-05-14 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-05-14 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2019-05-14 09:55:01 | 1) THE CORRECT ADDRESS FOR THIS PROJECT SHALL BE NOTED | | | ON ALL SUBMITTED SHEETS. "NARCISSUS AVENUE AND BANYAN | | | BLVD. IS INADEQUATE. WPB AMEND. TO FBC SEC. 107.2.1. | | | 2) THERE ARE ADDITIONAL PLUMBING DRAWINGS THAT HAVE | | | BEEN UPLOADED INTO THIS FOLDER THAT HAVE NOTHING TO DO | | | WITH THE SWIMMING POOL. THEY ARE PLUMBING DRAWINGS FOR | | | THE BUILDING.REMOVE THESE DRAWINGS FROM THE FOLDER AND | | | SUBMIT THE DRAWINGS THAT ARE APPLICABLE TO THE POOL | | | ONLY. WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-05-02 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-04-29 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-03-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-03-12 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-03-12 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2019-03-12 08:36:07 | 1) A REDUCED PRESSURE ZONE BACKFLOW PREVENTER IS | | | REQUIRED ON THE WATER SUPPLY TO THE COLLECTOR TANK PER | | | THE CITY OF WEST PALM BEACH CROSS CONNECTION CONTROL | | | MANUAL.2ND REQUEST. | | | 2) THE OPERABLE PARTS OF THE RINSE SHOWER SHALL COMPLY | | | WITH 2017 FBC-ACCESS SECS. 308 & 309. 2ND REQUEST. | | | 3) THERE ARE ADDITIONAL PLUMBING DRAWINGS THAT HAVE | | | BEEN UPLOADED INTO THIS FOLDER THAT HAVE NOTHING TO DO | | | WITH THE SWIMMING POOL. THEY ARE PLUMBING DRAWINGS FOR | | | THE BUILDING.REMOVE THESE DRAWINGS FROM THE FOLDER AND | | | SUBMIT THE DRAWINGS THAT ARE APPLICABLE TO THE POOL | | | ONLY. WPB AMEND. TO FBC SEC. 107.2.1. | | | 4) THE UPLOADED DRAWINGS HAVE NAMING CONVENTIONS THAT | | | DO NOT IDENTIFY THE DRAWING NUMBER. ALMOST EVERY SHEET | | | HAS TO BE OPENED TO SEE WHICH SHEET IT IS. PLEASE | | | CORRECT THIS ISSUE. | | | 5) MANUFACTURER'S SPECIFICATIONS HAVE BEEN SUBMITTED | | | FOR THE CONDENSATE DRAINS. PLEASE REFER TO MY ORIGINAL | | | PLAN REVIEW COMMENT. I REQUESTED THAT THE SIZE AND THE | | | TERMINATION POINT OF THE CONDENSATE DRAINS BE SHOWN ON | | | THE PLANS. THIS DOES NOT APPEAR TO HAVE BEEN DONE | | | COMPLY WITH ORIGINAL COMMENT. | | | 6) SIGNED AND SEALED CALCULATIONS AS REQUESTED WERE NOT | | | PROVIDED. SUBMIT THE TEST REPORTS OF THE FOAM FOR THE | | | FLAME SPREAD AND SMOKE DEVELOPED (ASTM E84 OR UL 723). | | | PROVIDE DETAILS ON THE PLANS OF HOW THE FOAM WILL BE | | | ENCASED IN CONCRETE AS REQUIRED BY FBC 603.1. | | | STRUCTURAL FOAM FILL IS SHOWN ON SHEET P2.2 BELOW THE | | | POOL. IT APPEARS THAT THIS FOAM WILL BE SUPPORTING THE | | | POOL. SUBMIT THE PRODUCT SPECIFICATIONS FOR THIS FOAM | | | WITH SIGNED AND SEALED ENGINEERED CALCULATIONS TO SHOW | | | THAT THE STRUCTURAL FOAM WILL SUPPORT THE FILLED POOL. | | | FBC 107.2.1.2 NOTE: FOAM IN TYPE I AND II BUILDINGS IS | | | REQUIRED TO BE ENCASED IN CONCRETE. FBC 603.1 | | | | | | | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2019-01-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-01-02 |
Time |
06:57 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-12-26 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2018-12-26 10:44:12 | PLAN REVIEW COMMENTS | | | | | | 1) THE ELECTRICAL PLAN SHEET E1.0 THAT IS LISTED IN THE | | | TABLE OF CONTENTS ON SHEET P1.0 WAS NOT UPLOADED. WITH | | | THIS SUBMITTAL. FBC 107.2.1 | | | 2) STRUCTURAL FOAM FILL IS SHOWN ON SHEET P2.2 BELOW | | | THE POOL. IT APPEARS THAT THIS FOAM WILL BE SUPPORTING | | | THE POOL. SUBMIT THE PRODUCT SPECIFICATIONS FOR THIS | | | FOAM WITH SIGNED AND SEALED ENGINEERED CALCULATIONS TO | | | SHOW THAT THE STRUCTURAL FOAM WILL SUPPORT THE FILLED | | | POOL. FBC 107.2.1.2 NOTE: FOAM IN TYPE I AND II | | | BUILDINGS IS REQUIRED TO BE ENCASED IN CONCRETE. FBC | | | 603.1. | | | 3) SHT. P2.1 - THE EQUALIZER IS SHOWN AS 2 INCH AND | | | ALSO AS 4 INCH. CLARIFY. | | | 4) THE PLANS SHALL BE DIGITALLY SIGNED AND SEALED PER | | | FL. ADMIN. CODE RULE 61G15-23.003, | | | 5) A VAPOR RETARDANT COVER ON OR AT THE WATER SURFACE | | | OR A LIQUID COVER OR OTHER MEANS PROVEN TO REDUCE HEAT | | | LOSS SHALL BE PROVIDED PER THE 2017 FBC-ENERGY SEC. | | | C404.9.3. | | | 6) THE EQUIPMENT ROOM SHALL HAVE EITHER FORCED DRAFT OR | | | CROSS VENTILATION PER 2017 FBC SEC. 4541.5.4. PROVIDE | | | DDETAILS. | | | 7) SHT. P2.2 - SHOW THE SIZE AND TERMINATION POINT OF | | | THE CONDENSATE DRAINS. | | | 8) SHT. P2.3 - TYPICAL MAIN DRAIN DETAILS CALLS OUT 3 | | | MAIN DRAINS BUT SHT. P2.1 SHOWS 4. CLARIFY. | | | 9) SHT.P2.0 - POOL MATERIALS & EQUIPMENT | | | LIST/PLUMBING/EQUIPMENT ROOM REFERS TO SHT. P4.0 FOR | | | COMPLETE SPECS. THERE IS NO SHT. P4.0 IN THIS | | | SUBMITTAL. CLARIFY. | | | 10) A REDUCED PRESSURE ZONE BACKFLOW PREVENTER IS | | | REQUIRED ON THE WATER SUPPLY TO THE COLLECTOR TANK PER | | | CITY OF WEST PALM BEACH CROSS CONNECTION CONTROL | | | MANUAL. | | | 11) THE OPERABLE PARTS OF THE RINSE SHOWER SHALL | | | CCOMPLY WITH THE 2017 FBC-ACCESS. SEC.309. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
6 |
Status |
P |
Date |
2019-07-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-07-09 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-07-09 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2019-06-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-06-14 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-06-12 |
Time |
06:21 |
Sent To |
|
|
| Notes |
| 2019-06-12 06:46:44 | SIGNATURES OK ON ALL PLUMBING DRAWINGS. T.LARGE |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-05-14 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-05-14 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2019-05-16 07:26:25 | DIGITAL SIGNATURE OK BUT PLANS WILL BE REPLACED | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2019-05-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-05-02 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-05-02 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2019-05-02 10:40:37 | SIGNATURES OK ON ALL SHEETS. TKL. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2019-03-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-03-19 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-03-19 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2019-03-19 10:57:34 | DIGITAL SIGNATURES FOR THE PAGES WHICH ARE DIGITALLY | | | SIGNED ARE OK. HOWEVER, NAMING CONVENTION IS NOT | | | CORRECT, MAKING PLAN REVIEW EXTREMELY DIFFICULT AND | | | TIME CONSUMING. REMOVAL OF ALL SHEETS AND UPLOADING OF | | | PROPERLY NAMED DIGITALLY SIGNED PAGES IS REQUIRED; | | | EMAILED APPLICANT. | | | | | | [email protected], 561-805-6724 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2018-11-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-11-27 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-11-27 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2018-11-27 14:26:48 | EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED AND SEALED | | | BY THE PERSON RESPONSIBLE FOR THE DESIGN. A DIGITAL | | | PLAN REQUIRES A DIGITAL SIGNATURE. PROVIDE CORRECTION. | | | WPB FBC 107.1; FS 471/481 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2019-06-14 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2019-06-14 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2019-06-14 |
Time |
15:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-05-09 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2019-05-09 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2019-05-09 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2019-05-09 15:11:54 | PROVISO: A MINOR SITE PLAN AMENDMENT SHALL BE SUBMITTED | | | TO REFLECT THE CHANGES FROM SITE PLAN APPROVAL. | | 2019-05-06 13:47:33 | ZONING WILL BE DONE NEXT REVIEW CYCLE PER AA | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-03-15 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2019-03-15 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2019-03-15 |
Time |
11:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-12-06 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2018-12-06 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2018-12-06 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|