Plan Review Details - Permit 18100991
Plan Review Stops For Permit 18100991
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-12-17 Cont ID  
Sent By dbattles Date 2018-12-17 Time 13:56 Rev Time 0.00
Received By dbattles Date 2018-12-17 Time 13:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-11-26 Cont ID  
Sent By jwitmer Date 2018-11-26 Time 08:49 Rev Time 0.00
Received By jwitmer Date 2018-11-26 Time 06:45 Sent To  
Notes
2018-11-26 08:49:412017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 18100991
 ADD: 901 N FLAGLER DR. SUITES: 1 & 2
 CONT: PAGE CONTRACTING
 TEL: 954-868-4561
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. NOV. 26/2018
 ACTION: DENIED
  
 1) SHEET A2.01:
 1A) SHEET A2.01 SHOWS A BREAKROOM WITH MICROWAVE AND A
 CUT SECTION 2D/A8.02. SHEET A8.20 DOES SHOW A CUT
 SECTION D THROUGH THE BREAKROOM CABINET DETAIL, BUT
 THERE IS NO SECTION SHOWING THE PLACEMENT OF THE
 MICROWAVE. IN THE LOWER CABINETS, OR ON THE COUNTER TOP
 OR IS IT ON A SHELF IN THE UPPER CABINETS.
 SHOW COMPLIANCE WITH 2017 FBC-ACCESSIBILITY CODE
 SECTIONS:
 308 REACH RANGES
 308.2 FORWARD REACH / 308.2.1 UNOBSTRUCTED/ 308.2.2
 OBSTRUCTED HIGH REACH.
 308.3 SIDE REACH / 308.3.1 UNOBSTRUCTED/ 308.3.2
 OBSTRUCTED HIGH REACH.
  
 309 OPERABLE PARTS
 309.3 HEIGHT. OPERABLE PARTS SHALL BE PLACED WITHIN ONE
 OR MORE OF THE REACH RANGES SPECIFIED IN 308.
  
 1B) THE PLAN INDICATES THIS IS A BUSINESS OCCUPANCY
 WITH 2 AREAS LABELED PIT, THE PLANS ARE SILENT AS TO
 WHAT THIS AREA IS TO BE USED FOR, THERE IS NO CHAIRS,
 TABLES OR KIOSK PLEASE PROVIDE ADDITIONAL INFORMATION,
 IT MAY AFFECT TRAVEL DISTANCES, OR OCCUPANT LOADS?
 107.2.2.1. ADDITIONAL INFORMATION IS REQUIRED.
  
 1C) SHEET A2.01 DOES INDICATE THE ARCHITECT IS
 MAINTAINING A 1 HOUR TENANT SEPARATION WALL BETWEEN THE
 EXISTING TENANT AND PROPOSED TENANT SPACE. A POINT OF
 CLARIFICATION NEEDS TO OCCUR BETWEEN A2.01 AND SHEET
 M1. AND M2. SHEET M2 MOUNTING DETAIL SHOWS A FRESH AIR
 DUCT WITH MOTORIZED DAMPER. SHEET M1 SHOWS WHAT APPEARS
 TO BE THE FRESH AIR DUCT WITHIN THE 1 HOUR FIRE RATED
 WALL AN UP THROUGH THE WALL AND THROUGH THE ROOF. THE
 PLAN DOES NOT SHOW COMPLIANCE WITH SECTION 714.3.2
 MEMBRANE PENETRATIONS OF THE 2017 FBC-B. MEMBRANE
 PENETRATIONS SHALL COMPLY WITH SECTION 714.3.1, WHERE
 WALLS OR PARTITIONS ARE REQUIRED TO HAVE
 FIRE-RESISTANCE RATINGS.
 PLEASE ALSO NOT IF THE FRESH AIR DUCT IS WITHIN THE A/C
 CLOSET AND THE FRESH AIR DUCT DOES NOT PENETRATE THE
 ONE HOUR FIRE RATED WALL, THEN NO FIRE DAMPER IS
 REQUIRED. CLARIFICATION IS REQUIRED. 107.2.2.1
 ADDITIONAL INFORMATION IS REQUIRED.
  
 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-12-17 Cont ID  
Sent By jpearson Date 2018-12-17 Time 13:15 Rev Time 0.00
Received By jpearson Date 2018-12-17 Time 13:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-11-06 Cont ID  
Sent By jpearson Date 2018-11-06 Time 08:51 Rev Time 0.00
Received By jpearson Date 2018-11-06 Time 07:22 Sent To  
Notes
2018-11-06 08:51:18CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
 (S)
  
 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS
 IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. FBC 109.3
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-10-25 Cont ID  
Sent By scaldero Date 2018-10-25 Time 10:31 Rev Time 0.00
Received By scaldero Date 2018-10-25 Time 10:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2018-12-18 Time   Rev Time 0.00
Received By lmarchan Date 2018-12-10 Time 15:05 Sent To  
Notes
2018-12-11 15:05:23B10

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-11-29 Cont ID  
Sent By jesmith Date 2018-11-29 Time 16:29 Rev Time 0.00
Received By jesmith Date 2018-11-29 Time 16:29 Sent To  
Notes
2018-11-15 16:13:55ROUTED FROM ZONING TO LM 11/15/18
2018-10-23 15:57:43B15

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2018-11-26 Cont ID  
Sent By jwitmer Date 2018-11-26 Time 08:49 Rev Time 0.00
Received By jwitmer Date 2018-11-26 Time 06:45 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-12-17 Cont ID  
Sent By hmoser Date 2018-12-17 Time 14:40 Rev Time 0.00
Received By hmoser Date 2018-12-17 Time 14:27 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2018-11-06 Cont ID  
Sent By cmontell Date 2018-11-06 Time 12:50 Rev Time 0.00
Received By cmontell Date 2018-11-06 Time 11:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-12-18 Cont ID  
Sent By jesmith Date 2018-12-18 Time 09:57 Rev Time 0.00
Received By jesmith Date 2018-12-18 Time 09:56 Sent To  
Notes
2018-12-18 09:57:15PPROVED
 PLUMBING PROVISO
 1. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S
 APPROVAL
 2. RE: PLAN PAGE P-1; NOTE 3, PROVIDE VENT DOWNSTREAM
 OF INTERCEPTOR IN ACCORDANCE W/FPC 909.1. AIR
 ADMITTANCE VALVE IS ACCEPTABLE.
 3. RE: PLAN PAGE P-3; WATER HEATER DETAIL, PROVIDE AIR
 GAP AS RED LINED FOR THE P & T AND THE EXPANSION VALVE
 DISCHARGE PIPINT TO SAFE PAN PER FBC PL 504.6.2 .
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-11-29 Cont ID  
Sent By jesmith Date 2018-11-29 Time 16:27 Rev Time 0.00
Received By jesmith Date 2018-11-29 Time 16:26 Sent To  
Notes
2018-11-29 16:27:09CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
  
 1.RE: PLAN PAGE P3; WASHING MACHINE DETAIL.
 A) PER FBC PL 1003.10, ACCESS SHALL BE PROVIDED TO EACH
 INTERCEPTOR AND SEPARATOR FOR SERVICE AND MAINTENANCE.
 INTERCEPTORS AND SEPARATORS SHALL BE MAINTAINED BY
 PERIODIC REMOVAL OF ACCUMULATED GREASE, SCUM, OIL, OR
 OTHER FLOATING SUBSTANCES AND SOLIDS DEPOSITED IN THE
 INTERCEPTOR OR SEPARATOR. THE ACCESS PANEL FOR THE LINT
 INTERCEPTOR BEHIND A WASHING MACHINE THAT WOULD HAVE TO
 BE DISCONNECTED AND MOVED TO PROVIDE ACCESS TO THE
 PANEL DOES NOT LEND ITSELF TO PERIODIC MAINTENANCE.
 ADDITIONALLY, INSTALLATION IS IN A 1HR FIRE RATED WALL.
 THE SIOUX CHIEF ACCESS PANEL NOTED IS NOT FIRE RATED.
 B) PROVIDE A UL LISTED WASHING MACHINE SUPPLY AND DRAIN
 BOX THAT WILL PROTECT THE INTEGRITY OF THE RATED WALL.
 WPB FBC 107.2.1
 C) PROVIDE WATER HAMMER ARRESTORS AT THE WASHING
 MACHINE PER FBC PL 604.9.
 2 .PROVIDE UL ASSEMBLIES FOR HORIZONTAL WATER, WASTE
 AND VENT PENETRATIONS FOR THE 1 HR FIRE RATED WALL IN
 THE BACK ROOM. WPB FBC 107.2.1
 3. PROVIDE UL LISTED ACCESS PANELS FOR IN-WALL VALVES
 AND TMV IN 1HR FIRE RATED WALL AT BACK ROOM.
 4. IS THE EXISTING WOMEN?S REST ROOM TO BE ADA
 COMPLIANT? IF SO, INDICATE ON THE PLANS AS ADA. WPB FBC
 107.2.1
 5. RE: PLAN PAGE P3; INSTA-HOT PIPING DETAIL.
 A) PROVIDE A FULL OPEN SUPPLY VALVE FOR THE WATER
 HEATER PER FBC PL 606.1.8. THREE-WAY ANGLE STOP SERVING
 THE SINK AND THE WATER HEATER IS PROHIBITED.
 6. WATER RISER DIAGRAM SHOWS TMV AT THE WATER HEATER.
 WATER HEATER DETAIL DOES NOT SHOW TMV. PLEASE CLARIFY.
 ADDITIONALLY, THE WATER RISER DIAGRAM SHOWS IN-WALL
 TMVS AT INDIVIDUAL FIXTURES. PLEASE CLARIFY. IN-WALL
 VALVES AND TMVS REQUIRE ACCESS PANELS. PLEASE SPECIFY.
 WPB FBC 107.2.1
 7. WATER RISER DIAGRAM SHOWS PAN AND DRAIN FOR THE
 WATER HEATER. WATER HEATER DETAIL DOES NOT. PLEASE
 CLARIFY. WPB FBC 107.2.1
 8. RE: PLAN PAGE P3; WASHING MACHINE DETAIL.
 A) PROVIDE WATER HAMMER ARRESTORS AT THE WASHING
 MACHINE PER FBC PL 604.9.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID".
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  

Review Stop Z ZONING
Rev No 1 Status P Date 2018-11-15 Cont ID  
Sent By elevesqu Date 2018-11-15 Time 16:13 Rev Time 0.00
Received By elevesqu Date 2018-11-15 Time 16:13 Sent To  
Notes
***NONE***