Plan Review Details - Permit 18100971
| Plan Review Stops For Permit 18100971 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-11-05 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-11-05 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-10-31 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2018-11-01 15:06:47 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-10-24 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-10-24 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-10-24 |
Time |
08:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-11-05 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-11-05 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-11-02 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2018-11-05 13:42:54 | 11/05/18 REVIEWED FOR CODE COMPLIANCE | | | (PLUMBING/BACKFLOW) | | | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | | / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO | | | AVOID VOIDING OF THE PERMIT. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER | | | | | 2018-11-02 14:49:05 | APPROVED BY PLUMBING. SENT TO UTILITIES FOR REVIEW.TKL. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-10-24 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-10-24 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-10-24 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2018-10-24 08:50:12 | 1) A PRESSURE VACUUM BREAKER ASSEMBLY IS NOT PERMITTED | | | ON A NON-RESIDENTIAL IRRIGATION SYSTEM PER THE CITY OF | | | WEST PALM CROSS-CONNECTION CONTROL MANUAL. THE MINIMUM | | | LEVEL OF PROTECTION IS A REDUCED PRESSURE ZONE VALVE | | | ASSEMBLY. | | | 2) ALL DEVICES MUST BE LEAD FREE AND APPROVED BY THE | | | FOUNDATION FOR CROSS-CONNECTION CONTROL AND HYDRAULIC | | | RESEARCH AT THE UNIVERSITY OF SOUTHERN CALIFORNIA. | | | 3) AS AN FYI - ALL NEW DEVICES MUST BE TESTED AND | | | CERTIFIED BY THE CITY OF WEST PALM BEACH UTILITIES | | | DEPT. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
|