Plan Review Details - Permit 18100808
| Plan Review Stops For Permit 18100808 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-11-13 |
|
|
Cont ID |
|
| Sent By |
bwoods |
Date |
2018-11-13 |
Time |
00:00 |
Rev Time |
0.00 |
| Received By |
bwoods |
Date |
2018-11-01 |
Time |
00:00 |
Sent To |
M |
|
| Notes |
| 2018-11-13 09:04:05 | 6.2.2.2* THIS PROTECTION SHALL BE PERMITTED TO BE | | | ACCOMPLISHED | | | BY THE INSTALLATION OF A STEEL OR STAINLESS STEEL | | | BAFFLE | | | PLATE BETWEEN THE HEAT SOURCE AND THE GREASE REMOVAL | | | DEVICE. | | | 6.2.2.3 THE BAFFLE PLATE SHALL BE SIZED AND LOCATED SO | | | THAT | | | FLAMES OR COMBUSTION GASES TRAVEL A DISTANCE NOT LESS | | | THAN | | | 457 MM (18 IN.) FROM THE HEAT SOURCE TO THE GREASE | | | REMOVAL | | | DEVICE. | | | 6.2.2.4 THE BAFFLE SHALL BE LOCATED NOT LESS THAN 152 | | | MM (6 IN.) | | | FROM THE GREASE REMOVAL DEVICE. | | | | | | | | | FINAL REVIEW AND TESTING SUBJECT TO FIELD INSPECTION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-11-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-10-17 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2018-10-18 14:32:52 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-01-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-01-31 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-01-31 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-11-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-11-20 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-11-20 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2018-11-20 14:53:43 | | | | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18100808 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE ENGINEER OF RECORD FOR THE KITCHEN EXHAUST HOODS | | | PROJECT LARRY A. PETERS P.E. SHALL PROVIDE A SHOP | | | DRAWING APPROVAL STAMP ON THE FIRE SUPPRESSION DRAWINGS | | | AND SPECIFICATIONS- SECTION 107.2.1 WPB. | | | | | | 2) THE PERMIT VALUE OF $2475.00 APPEARS LOW FOR THE | | | SCOPE OF THE PROJECT. PLEASE PROVIDE ESTIMATES AND/OR | | | SIGNED CONTRACTS FOR THE ENTIRE FIRE SUPPRESSION | | | INSTALLATION INCLUDING LABOR, MATERIALS, AND EQUIPMENT- | | | SECTION 109.3WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
|