| Plan Review Stops For Permit 18100659 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-01-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-01-18 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-01-18 |
Time |
08:15 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-01-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-01-02 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-01-02 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2019-01-02 10:52:21 | TENANT IMPROVEMENTS, SECOND BUILDING REVIEW CHECKLIST. | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | ORIGINAL COMMENT: | | | 1- CLARIFY DIRECTION OF EGRESS DOOR LOCATED ON THE EAST | | | SIDE BY THE STAIRWAY. ACCORDING TO APPROVED PERMIT | | | #12030212 THE DOOR SWING OF THIS DOOR WAS IN THE | | | DIRECTION OF TRAVEL (OUT SWING). REVISE AS REQUIRED. | | | SEC. 1010.1.2.1 FBC. | | | | | | RESPONSE: | | | RESPONSE LETTER STATES THAT THIS DOOR IS CLOSED ON | | | PHASE II (PERMIT #18111051). PLEASE STATE SO IN PLANS | | | FOR CLARIFICATION AND TO AVOID CONFLICTS. | | | | | | ORIGINAL COMMENT: | | | 2- PROVIDE THE OCCUPANT LOAD FOR TENANT SPACE LOCATED | | | IN THE SOUTH WEST CORNER TO VERIFY COMPLIANCE WITH THE | | | SWING OF THE DOUBLE EGRESS DOOR. SEC. 1010.1.2.1 FBC. | | | | | | RESPONSE: | | | RESPONSE LETTER STATES THAT THE DOUBLE INSWING DOORS | | | ARE SHOWN ON PHASE II (PERMIT #18111051) PLANS TO SWING | | | IN THE DIRECTION OF TRAVEL. PHASE II PLANS ONLY SHOW | | | ONE SET OF DOUBLE DOORS SWINGING IN THE DIRECTION OF | | | TRAVEL FOR THE SOUTH EAST CORNER TENANT SPACE. THE | | | SWING OF THE DOUBLE DOORS FOR THE TENANT SPACE IN | | | QUESTION WERE NOT CHANGED. PLEASE PROVIDE THE OCCUPANT | | | LOAD FOR THIS TENANT SPACE. IDENTIFY ALL ROOMS AND | | | PROVIDE OCCUPANT LOAD. SEC. 1010.1.2.1 FBC AND TABLE | | | 10104.1.2 FBC. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | PLEASE DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS | | | FOR REFERENCE. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-11-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-11-19 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-11-16 |
Time |
18:01 |
Sent To |
|
|
| Notes |
| 2018-11-19 12:04:43 | BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1- MISSING EXIT SIGN BETWEEN THE OPEN OFFICE AREA AND | | | BREAK ROOM. SEC. 1013.1 FBC | | | | | | 2- CLARIFY DIRECTION OF EGRESS DOOR LOCATED ON THE EAST | | | SIDE BY THE STAIRWAY. ACCORDING TO APPROVED PERMIT | | | #12030212 THE DOOR SWING OF THIS DOOR WAS IN THE | | | DIRECTION OF TRAVEL (OUT SWING). REVISE AS REQUIRED. | | | SEC. 1010.1.2.1 FBC. | | | | | | 3- PROVIDE THE OCCUPANT LOAD FOR TENANT SPACE LOCATED | | | IN THE SOUTH WEST CORNER TO VERIFY COMPLIANCE WITH THE | | | SWING OF THE DOUBLE EGRESS DOOR. SEC. 1010.1.2.1 FBC. | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | PLEASE DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS | | | FOR REFERENCE. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-01-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-01-16 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-01-16 |
Time |
08:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-12-20 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-12-20 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-12-20 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2018-12-20 11:07:00 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. THERE ARE 2 DIFFERENT ELECTRICAL PLANS PROVIDED IN | | | THIS SUBMISSION WITH CONFLICTING INFORMATION. THE PLAN | | | PROVIDED BY KAMM HAS AREAS CROSSED OUT WITH GREEN | | | MARKER, WHICH IS NOT ACCEPTABLE. PROVIDE CLARIFICATION | | | AND ONE ELECTRICAL PLAN FOR REVIEW. WPB FBC 107.2.1 | | | (TWO DIFFERENT ELECTRICAL PLANS STILL IN BOTH SETS. | | | REMOVE ANY UNUSED OR INCORRECT INFORMATION FROM | | | SUBMITTAL.) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-10-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-29 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-29 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2018-10-29 07:56:11 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. THERE ARE 2 DIFFERENT ELECTRICAL PLANS PROVIDED IN | | | THIS SUBMISSION WITH CONFLICTING INFORMATION. THE PLAN | | | PROVIDED BY KAMM HAS AREAS CROSSED OUT WITH GREEN | | | MARKER, WHICH IS NOT ACCEPTABLE. PROVIDE CLARIFICATION | | | AND ONE ELECTRICAL PLAN FOR REVIEW. WPB FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-01-10 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2019-01-10 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2019-01-10 |
Time |
11:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-10-17 |
Time |
00:00 |
Rev Time |
|
| Received By |
|
Date |
2018-10-17 |
Time |
00:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-01-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2019-01-18 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2019-01-08 |
Time |
16:36 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-01-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-01-07 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-12-10 |
Time |
15:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-11-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-11-19 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-10-15 |
Time |
14:43 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2018-11-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-11-19 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-11-19 |
Time |
07:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-12-21 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-12-21 |
Time |
14:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-11-06 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-11-06 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-11-06 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-01-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-01-07 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-01-07 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2019-01-07 11:01:00 | APPROVED BY DOUG CARROLL P0013 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-11-08 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-11-08 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-11-08 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2018-11-08 10:22:35 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 1ST REVIEW: DENIED | | | COMMENTS: | | | 1. RE: SANITARY RISER DIAGRAM | | | A) LIBERTY #404 DRAIN PUMP IS SHOWN IN THE CEILING. | | | THERE IS A NEW 2" GRAVITY DRAIN CONNECTING THE SINK TO | | | EXISTING SANITARY. THE NEW VENT RISES AND CONNECTS TO | | | THE DRAIN PUMP, THEN CONNECTS FROM DRAIN PUMP TO | | | EXISTING VENT. THERE IS A 2" (DRAIN/DISCHARGE?) | | | INTERSECTING WITH THE GRAVITY DRAIN, TRAPPED FIXTURE | | | DRAIN AND VENT. IT SHOULD BE NOTED THAT THE DRAIN PUMP | | | IS DESIGNED TO RECEIVE WASTE BY GRAVITY FROM FIXTURES | | | AND THEN DISCHARGE TO A GRAVITY DRAIN IN ACCORDANCE | | | WITH REQUIREMENTS OF FBC PL SECTION 712 AND FBC PL | | | 906.5.1. PLEASE CLARIFY. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | | | | |
|
|