Plan Review Details - Permit 18100654
Plan Review Stops For Permit 18100654
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-12-26 Cont ID  
Sent By dbattles Date 2018-12-26 Time 14:30 Rev Time 0.00
Received By dbattles Date 2018-12-26 Time 14:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-12-05 Cont ID  
Sent By dbattles Date 2018-12-05 Time 16:15 Rev Time 0.00
Received By dbattles Date 2018-12-05 Time 15:15 Sent To  
Notes
2018-12-05 16:15:24****CORRECTIONS****
 W.P.B. PERMIT: 18100654
 REVIEWED: DECEMBER 5, 2018
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC ENERGY = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. [FBC ENERGY 103.1.1.2]CODE COMPLIANCE CERTIFICATION.
 THE BUILDING?S OWNER, THE OWNER?S ARCHITECT OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH THE
 CODE, AS PER SECTION 553.907, FLORIDA STATUTES, PRIOR
 TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION.
 553.907, FLORIDA STATUTES
 HAVE OWNER SIGN ENERGY CALCULATIONS UNDER THE PREPARED
 BY SIGNATURE.
 SUPPLY TWO COPIES BECAUSE WE ONLY RECEIVED ONE COPY OF
 UNSIGNED ENERGY CALCULATIONS.
  
 2. [FBC 107.2.5]UPDATE CODE REFERENCES ON SHEET 1 TO
 STATE COMPLIANCE WITH FBC 2017 6TH EDITION INSTAED OF
 THE PREVIOUS VERSION AS SUBMITTED.
  
 3. [FBC R318]INDICATE THE MEANS OF TERMITE PROTECTION
 PROPOSED AND REFERENCE SECTION R308 FOR STANDARDS.
 HOW WILL NEW SPACE MEET REQUIREMENTS FRO TERMITE
 TREATMENT?
  
 4. [FBC R506.2.3]VAPOR RETARDER.
 A 6-MIL (0.006 INCH; 152 ?M) POLYETHYLENE OR APPROVED
 VAPOR RETARDER WITH JOINTS LAPPED NOT LESS THAN 6
 INCHES (152 MM) SHALL BE PLACED BETWEEN THE CONCRETE
 FLOOR SLAB AND THE BASE COURSE OR THE PREPARED SUBGRADE
 WHERE NO BASE COURSE EXISTS.
 HOW WILL VAPOR BARRIER BE INSTALLED?
  
 NOTE:
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-11-05 Cont ID  
Sent By fgiaquin Date 2018-11-05 Time 10:10 Rev Time 0.00
Received By fgiaquin Date 2018-11-05 Time 09:17 Sent To  
Notes
2018-11-05 10:10:45PASSED WITH PROVISO:
  
 PROVIDE LOAD CALC OF EXISTING LOAD, THEN WITH NEW LOAD
 ADDED TO IT. BEFORE FINAL INSPECTION. LOAD CALC
 PROVIDED IS NOT COMPLETE.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-01-08 Cont ID  
Sent By cpuell Date 2019-01-08 Time 16:20 Rev Time 0.00
Received By cpuell Date 2018-12-20 Time 10:55 Sent To  
Notes
2018-12-21 10:55:23R28

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-12-05 Cont ID  
Sent By dbattles Date 2018-12-05 Time 16:16 Rev Time 0.00
Received By dbattles Date 2018-10-15 Time 14:48 Sent To  
Notes
2018-10-16 14:48:24R16

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2018-12-26 Cont ID  
Sent By dbattles Date 2018-12-26 Time 14:30 Rev Time 0.00
Received By dbattles Date 2018-12-26 Time 14:30 Sent To  
Notes
2018-12-26 14:31:07MU # 2018-041377-0000
 PLAN STAMPED - OK

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-12-05 Cont ID  
Sent By dbattles Date 2018-12-05 Time 16:15 Rev Time 0.00
Received By dbattles Date 2018-12-05 Time 15:15 Sent To  
Notes
2018-12-05 16:16:40DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
 [FBC AMENDED 109]PLANS REQUIRE REVIEW BY THE PBC IMPACT
 FEE OFFICE. CALL (561) 233-5025. UPON APPROVAL, YOU MAY
 CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR
 REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF THE
 RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE
 OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO
 V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN
 AIRE.PDF
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-01-02 Cont ID  
Sent By cmontell Date 2019-01-02 Time 14:35 Rev Time 0.00
Received By cmontell Date 2019-01-02 Time 14:31 Sent To  
Notes
2019-01-02 14:34:49MECHANICAL PLAN REVIEW PASS WITH PROVISO (SEE PLANS)
  
 R303.10REQUIRED HEATING.WHERE THE WINTER DESIGN
 TEMPERATURE IN TABLE R301.2(1) IS BELOW 60?F (16?C),
 EVERY DWELLING UNIT SHALL BE PROVIDED WITH HEATING
 FACILITIES CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF
 NOT LESS THAN 68?F (20?C) AT A POINT 3 FEET (914 MM)
 ABOVE THE FLOOR AND 2 FEET (610 MM) FROM EXTERIOR WALLS
 IN HABITABLE ROOMS AT THE DESIGN TEMPERATURE. THE
 INSTALLATION OF ONE OR MORE PORTABLE SPACE HEATERS
 SHALL NOT BE USED TO ACHIEVE COMPLIANCE WITH THIS
 SECTION.
  
  
 CHRIS MONTELLO
 561-503-3556
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-11-06 Cont ID  
Sent By cmontell Date 2018-11-06 Time 09:32 Rev Time 0.00
Received By cmontell Date 2018-11-06 Time 09:22 Sent To  
Notes
2018-11-06 09:28:55MECHANICAL PLAN REVIEW FAIL
  
 1 NEED MECHANICAL PLANS PER 2017 FLORIDA BUILDING CODE
 SEC. [A]107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
  
 CHRIS MONTELLO
 561-805-6733
 [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2019-01-08 Cont ID  
Sent By awooten Date 2019-01-08 Time   Rev Time 0.00
Received By awooten Date 2019-01-08 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2018-10-26 Cont ID  
Sent By awooten Date 2018-10-26 Time   Rev Time  
Received By awooten Date 2018-10-26 Time   Sent To  
Notes
2018-10-26 10:35:57*********************************************ZONING
 REVIEW FAILED************************************
  
 PROVIDE A SURVEY SHOWING EXISTING SETBACKS AND PARKING
 FOR 2 CARS, SINCE YOU ARE ENCLOSING CARPORT.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved