Plan Review Details - Permit 18100590
| Plan Review Stops For Permit 18100590 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-10-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-10-23 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-10-19 |
Time |
12:00 |
Sent To |
M |
|
| Notes |
| 2018-10-19 12:00:54 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) SHEET G 1.0 - THERE IS AN INCORRECT EDITION, 2012, | | | OF NFPA INDICATED. | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 6TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2015 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | | | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 241, 2013 EDITION. | | | | | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 10, 2013 EDITION. | | | | | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2014 EDITION. | | | | | | FLAMMABLE AND COMBUSTIBLE LIQUIDS SHALL COMPLY WITH | | | NFPA 30, 2015 EDITION | | | | | | MOTOR FUEL DISPENSING FACILITIES AND REPAIR GARAGES | | | SHALL COMPLY WITH NFPA 30 A, 2015 EDITION | | | | | | | | | PLEASE REVIEW AND ENSURE COMPLIANCE AS THIS IS WHAT | | | WILL BE USED FOR FIRE INSPECTIONS. | | | | | | PLEASE UPDATE YOUR REFERNCES AND ENSURE FUTURE | | | SUBMITTALS ARE CORRECTED. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-10-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-10-23 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-10-12 |
Time |
09:47 |
Sent To |
FIRE |
|
| Notes |
| 2018-10-16 09:47:21 | **TRAVELLING TOGETHER - 18100588 & 18100590** |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2018-10-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-10-23 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-10-23 |
Time |
10:18 |
Sent To |
I |
|
| Notes |
| 2018-10-23 11:21:30 | PASS PROVISO | | | 1) CALL AND SCHEDULE 610 UNDERGROUND TANKS. MECHANICAL | | | INSPECTOR | | | MUST INSPECT FUEL TANKS BE FOR THEY ARE MOVED OFF THE | | | PROPERTY. | | | 2) REFER TO SECTION 1303.1.1 JOINTS BETWEEN DIFFERENT | | | PIPING | | | MATERIALS 2017 FBC (M) | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 | | | |
|
|
|