| 2018-11-07 17:19:04 | RESIDENTIAL (R3) BUILDING REVIEW COMMENTS |
| | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| | |
| | 1- SCOPE OF WORK IS NOT CLEAR. DESCRIPTION OF WORK IN |
| | THE PERMIT APPLICATION CALLS FOR "REMOVAL OF 4 WINDOWS |
| | AND REPLACED WITH IDENTICAL MATCHING SIDING & FRAMING". |
| | CLARIFY WHAT IS THE SCOPE OF WORK IN FRAMING. IF |
| | FRAMING IS FOR THE WINDOWS, THEN PROVIDE COMPLETE |
| | FRAMING DETAILS AND SPECIFICATIONS. SPECIFY ALL FRAMING |
| | MEMBERS AND ALL CONNECTORS. SEC. R301.1 |
| | FBC-RESIDENTIAL. ALSO, PROVIDE SPECIFICATIONS FOR TYPE |
| | OF SIDING AND AREAS OF WORK. SEC. 107.2.1 CITY |
| | AMENDMENTS. |
| | |
| | 2- CLEARLY SPECIFY THE TYPE AND SIZE OF EXISTING WINDOW |
| | AND TYPE AND SIZE OF PROPOSED WINDOW. NEED THIS TO |
| | VERIFY COMPLIANCE WITH THE BEDROOM EGRESS REQUIREMENTS |
| | AS REQUIRED BY SEC. 702.5 FBC-EXISTING BUILDING. |
| | NOTE: IF THERE ARE TWO WINDOWS MULLED TOGETHER IN THE |
| | BEDROOM, THEN THERE ARE 5 WINDOWS TOTAL NOT 4. |
| | |
| | 3- CLEARLY IDENTIFY EACH ROOM, INCLUDING ROOM WHERE |
| | WINDOWS #2 AND #3 ARE GOING TO BE REPLACED. SEC. |
| | 107.2.1 CITY AMENDMENTS. |
| | |
| | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | FAC 61G20-3.001 FOR: |
| | A) TYPE OF WINDOWS TO BE INSTALLED. NOTE: IF WINDOWS |
| | DON'T HAVE IMPACT GLASS, THEN HURRICANE SHUTTERS MAY BE |
| | REQUIRED. (HURRICANE SHUTTERS PRODUCT APPROVAL AND |
| | COMPLETE INSTALLATION SCHEDULE WILL BE REQUIRED. |
| | COORDINATE WITH HISTORIC DEPARTMENT FOR SHUTTERS |
| | INSTALLATION APPROVAL) |
| | |
| | B) WINDOW MULLIONS AS SHOWN ON PLANS. AND, CLEARLY MARK |
| | MULLION SIZE TO VERIFY COMPLIANCE WITH THE CALCULATED |
| | DESIGN PRESSURES. |
| | |
| | 5-- FLOOR PLANS SUBMITTED NEED TO HAVE THE NAME AND |
| | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN AS |
| | REQUIRED BY SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 6- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO |
| | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, |
| | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN |
| | PROFESSIONAL FEES (IF ANY) AS REQUIRED BY SEC. 109.3 |
| | CITY AMENDMENTS. UPDATE VALUATION. |
| | |
| | |
| | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. |
| | |
| | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY |
| | REVIEWED DRAWINGS. DO NOT STAPLE OLD DRAWINGS TO PLANS. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |