Plan Review Details - Permit 18100482
| Plan Review Stops For Permit 18100482 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-12-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-14 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-14 |
Time |
09:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-11-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-11-02 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-11-02 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2018-11-02 12:49:20 | ****CORRECTIONS**** | | | COURTESY REVIEW AFTER NEW INFORMATION FROM GC | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | | | | 1. FBC 107, CLARIFY SCOPE. IT APPEARS THAT A PORTION OF | | | THE ROOF (<25%) NEEDS TO BE REMOVED AND REPLACED, AND | | | THE REMAINDER RECOVERED. APPLICATION PROPOSES A | | | RECOVER. DRAINS AND SCUPPERS ARE SHOWN; IT IS NOT CLEAR | | | IF THESE ARE PROPOSED OR EXISTING. DRAINAGE | | | CALCULATIONS MAY BE REQUIRED. | | | | | | 2ND REVIEW - PER CONTRACTOR, THE PORTION WITH EXCESS | | | MOISTURE IS TO BE REMOVED AND REPLACED, SCUPPERS AND | | | DRAINS EXISTING. IS THIS CORRECT? | | | | | | PROVIDE AN ASSEMBLY FOR THE PORTION OF ROOF REQUIRING A | | | REROOF. | | | | | | IT IS NOT CLEAR WHY ROOFING CONTRACTOR IS PROPOSING A | | | RECOVER AND ENGINEER PROVIDES CALCULATIONS FOR RECOVER | | | WHEN ENGINEER'S MOISTURE TEST SHOWS EXCESSIVE MOISTURE; | | | PLEASE CLARIFY. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-10-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-15 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-15 |
Time |
08:02 |
Sent To |
|
|
| Notes |
| 2018-10-15 08:14:46 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC 107, CLARIFY SCOPE. IT APPEARS THAT A PORTION OF | | | THE ROOF (<25%) NEEDS TO BE REMOVED AND REPLACED, AND | | | THE REMAINDER RECOVERED. APPLICATION PROPOSES A | | | RECOVER. DRAINS AND SCUPPERS ARE SHOWN; IT IS NOT CLEAR | | | IF THESE ARE PROPOSED OR EXISTING. DRAINAGE | | | CALCULATIONS MAY BE REQUIRED. | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-12-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-14 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-10 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2018-12-11 10:08:29 | RESUB ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-10-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-15 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-10 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
|