Plan Review Details - Permit 18100323
| Plan Review Stops For Permit 18100323 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-11-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-11-15 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-11-15 |
Time |
10:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-10-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-10-12 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-10-12 |
Time |
12:29 |
Sent To |
|
|
| Notes |
| 2018-10-12 13:35:32 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | NEED TO SHOW SIZE OF BRANCH CIRCUITS | | | | | | E3701.2BRANCH-CIRCUIT AND FEEDER AMPACITY. | | | BRANCH-CIRCUIT AND FEEDER CONDUCTORS SHALL HAVE | | | AMPACITIES NOT LESS THAN THE MAXIMUM LOAD TO BE SERVED. | | | WHERE A BRANCH CIRCUIT | | | OR A FEEDER SUPPLIES CONTINUOUS LOADS OR ANY | | | COMBINATION OF CONTINUOUS AND NONCONTINUOUS LOADS, THE | | | MINIMUM BRANCH-CIRCUIT OR | | | FEEDER CONDUCTOR SIZE, BEFORE THE APPLICATION OF ANY | | | ADJUSTMENT OR CORRECTION FACTORS, SHALL HAVE AN | | | ALLOWABLE AMPACITY EQUAL TO OR | | | GREATER THAN THE NONCONTINUOUS LOAD PLUS 125 PERCENT OF | | | THE CONTINUOUS LOAD. [210.19(A)(1)(A) AND | | | 215.2(A)(1)(A)] | | | | | | NEED TO SHOW LOCATION OF EQUIPMENT INSIDE AND OUTSIDE. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS | | | | | | REVIEWS ARE COMPLETE; HOWEVER YOUR APPLICATION HAS NOT | | | BEEN APPROVED. YOU CAN VIEW THE COMMENTS BY SELECTING | | | THE PLAN REVIEWS TAB AT: HTTP://ONESTOPSHOP.WPBGOV.COM/ | | | EGOVPLUS/PERMIT/PERM_STATUS.ASPX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-11-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-11-15 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-11-06 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2018-11-07 14:32:09 | RESUB ROUTED TO JLEAHY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-10-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-10-12 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-10-05 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2018-10-09 14:13:41 | ELEC <5K |
|
|
|