Plan Review Details - Permit 18100316
Plan Review Stops For Permit 18100316
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-10-23 Cont ID  
Sent By jgomez Date 2018-10-23 Time 18:23 Rev Time 0.00
Received By jgomez Date 2018-10-23 Time 17:37 Sent To  
Notes
2018-10-23 17:38:06BUILDING REVIEW APPROVED WITH PROVISO:
 SEE INSTALLATION SCHEDULE RED-LINED/HIGHLIGHTED ITEMS
 FOR REQUIREMENTS TO BE VERIFIED IN THE FIELD.
 PROVIDE CLEAR/CORRECT INSTALLATION SCHEDULES ON FUTURE
 SUBMITTALS
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-10-17 Cont ID  
Sent By jgomez Date 2018-10-17 Time 10:52 Rev Time 0.00
Received By jgomez Date 2018-10-16 Time 18:48 Sent To  
Notes
2018-10-16 18:52:50RESIDENTIAL (R2) BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 1- PROVIDE SHUTTERS COMPLETE INSTALLATION SCHEDULE AS
 REQUIRED BY CITY IMPLEMENTATION STANDARD FOR WIND-BORNE
 DEBRIS IMPACT PROTECTION FOR THE FLORIDA BUILDING CODE.
 SEE CITY SAMPLE. ALL THE COLUMNS NEED TO BE COMPLETED.
 ALTERNATIVELY, YOU MAY PROVIDE COMPLETE INSTALLATION
 SCHEDULE IN ANY OTHER FORMAT AS LONG AS ALL THE
 REQUIRED INFORMATION IS PROVIDED.
  
 RESPONSE:
 A) ACCORDING TO DESIGN PRESSURES HIGHLIGHTED ON
 ENGINEER CALCULATIONS THE ANCHOR SPACING FOR TOP
 CONNECTION IS 5.5" FOR TYPE OF ANCHOR SPECIFIED NOT
 6.5". AND THE ANCHOR SPACING FOR BOTTOM CONNECTION IS
 4" NOT 7.5". REVISE AS REQUIRED BY THE PRODUCT APPROVAL
 SUBMITTED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 B) CLEARLY SPECIFY THE MINIMUM EDGE DISTANCE AS
 REQUIRED BY INSTALLATION DETAILS "G" AND "J" ON PRODUCT
 APPROVAL SUBMITTED. CLARIFY WHAT IS EDGE DISTANCE
 "TRAPPED" AS SPECIFIED ON THE SHUTTER INSTALLATION
 SCHEDULE SUBMITTED?.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 2- ENGINEER CALCULATIONS SUBMITTED NEED TO HAVE THE
 ORIGINAL SEAL AND SIGNATURE OF THE ENGINEER OF RECORD
 AS REQUIRED BY SEC. 61G15-23.003 FAC AND CHAPTER 471
 F.S. WHEN SUBMITTING PLANS/DOCUMENTS FOR PUBLIC
 RECORDS.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-10-10 Cont ID  
Sent By jgomez Date 2018-10-10 Time 13:43 Rev Time 0.00
Received By jgomez Date 2018-10-10 Time 13:40 Sent To  
Notes
2018-10-10 13:50:43RESIDENTIAL (R2) BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- PROVIDE SHUTTERS COMPLETE INSTALLATION SCHEDULE AS
 REQUIRED BY CITY IMPLEMENTATION STANDARD FOR WIND-BORNE
 DEBRIS IMPACT PROTECTION FOR THE FLORIDA BUILDING CODE.
 SEE CITY SAMPLE. ALL THE COLUMNS NEED TO BE COMPLETED.
 ALTERNATIVELY, YOU MAY PROVIDE COMPLETE INSTALLATION
 SCHEDULE IN ANY OTHER FORMAT AS LONG AS ALL THE
 REQUIRED INFORMATION IS PROVIDED.
  
 2- ENGINEER CALCULATIONS SUBMITTED NEED TO HAVE THE
 ORIGINAL SEAL AND SIGNATURE OF THE ENGINEER OF RECORD
 AS REQUIRED BY SEC. 61G15-23.003 FAC AND CHAPTER 471
 F.S. WHEN SUBMITTING PLANS/DOCUMENTS FOR PUBLIC RECORDS
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-10-23 Cont ID  
Sent By jgomez Date 2018-10-23 Time 18:23 Rev Time 0.00
Received By jgomez Date 2018-10-22 Time 15:15 Sent To I
Notes
2018-10-23 15:16:03RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-10-17 Cont ID  
Sent By jgomez Date 2018-10-17 Time 10:53 Rev Time 0.00
Received By jgomez Date 2018-10-15 Time 13:34 Sent To I
Notes
2018-10-16 13:34:59RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-10-10 Cont ID  
Sent By jgomez Date 2018-10-10 Time 13:50 Rev Time 0.00
Received By jgomez Date 2018-10-05 Time 13:23 Sent To I
Notes
2018-10-09 13:24:10BLDG <5K