Plan Review Details - Permit 18100278
| Plan Review Stops For Permit 18100278 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-01-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-25 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-25 |
Time |
15:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-01-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-15 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-14 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2019-01-15 11:26:23 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | ADVISORY: | | | F.S. 553.80 (2) (B) | | | (B)?WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | 1. NOA 17-0630.08 SUBMITTED FOR REVIEW DOES NOT APPEAR | | | ON THE SUBMITTED WINDOW SCHEDULE. PLEASE CLARIFY. | | | 2. PROVIDE PRODUCT APPROVALS FOR PROPOSED DOORS. | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | PROVISO | | | | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON | | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | | OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-12-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-31 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-31 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2018-12-31 13:14:42 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR NEW WINDOWS AND DOORS. | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-11-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-11-15 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-11-15 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2018-11-15 09:52:47 | RESIDENTIAL (R3)ALTERATION, BUILDING REVIEW COMMENTS | | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1- PLANS NEED TO SPECIFY THE CURRENT CODE FBC 6TH | | | EDITION (2017). CHAPTER 553 FLORIDA STATUTE. | | | | | | 2- PLANS NEED TO SPECIFY THE DESIGN CRITERIA, INCLUDING | | | ULTIMATE AND NOMINAL WIND LOADS, BUILDING EXPOSURE, | | | MEAN ROOF HEIGHT, DESIGN PRESSURES FOR EXTERIOR DOORS | | | AND WINDOWS. SEC. R301.2.1 FBC-RESIDENTIAL. | | | | | | 3- PROVIDE COMPLETE SECOND FLOOR FRAMING PLAN AND ROOF | | | FRAMING PLAN FRO AREAS TO BE RE-FRAMED. SPECIFY ALL | | | FRAMING MEMBERS SIZE, SPACING AND CONNECTORS. SEC. | | | R301.1 FBC-RESIDENTIAL. | | | | | | 4- PROVIDE COMPLETE WALL FRAMING DETAILS AND | | | SPECIFICATIONS FOR WALL AREAS TO BE RE-FRAMED. SPECIFY | | | ALL FRAMING MEMBERS SIZE, SPACING AND CONNECTORS AND | | | INTERIOR AND EXTERIOR COMPONENTS (DRYWALL, WALL | | | SHEATHING, STUCCO, ETC.). SEC. R301.1 FBC-RESIDENTIAL. | | | | | | 5- PROVIDE COMPLETE WINDOW WALL FRAMING DETAILS AND | | | SPECIFICATIONS FOR RELOCATED WINDOW AS SPECIFIED ON | | | DEMOLITION ROOF FLOOR PLAN. SPECIFY ALL FRAMING MEMBERS | | | SIZE AND CONNECTORS. SEC. R301.1 FBC-RESIDENTIAL. | | | | | | 6- CLEARLY SPECIFY TYPE AND SIZE OF EXISTING WINDOWS | | | AND TYPE AND SIZE OF PROPOSED WINDOWS TO VERIFY | | | COMPLIANCE WITH THE EGRESS REQUIREMENTS OF SEC. 702.5 | | | FBC-EXISTING BUILDING. | | | NOTE: CLEARLY IDENTIFY IN ALL FLOOR PLANS ALL ROOMS. | | | | | | 702.5EMERGENCY ESCAPE AND RESCUE OPENINGS. | | | WHERE WINDOWS ARE REQUIRED TO PROVIDE EMERGENCY ESCAPE | | | AND RESCUE OPENINGS IN GROUP R-2 AND R-3 OCCUPANCIES | | | AND ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES | | | REGULATED BY THE FLORIDA BUILDING CODE, RESIDENTIAL, | | | REPLACEMENT WINDOWS SHALL BE EXEMPT FROM THE | | | REQUIREMENTS OF SECTIONS 1030.2, 1030.3 AND 1030.5 OF | | | THE FLORIDA BUILDING CODE, BUILDING AND SECTIONS | | | R310.21 AND R310.2.3 OF THE FLORIDA BUILDING CODE, | | | RESIDENTIAL ACCORDINGLY, PROVIDED THE REPLACEMENT | | | WINDOW IS THE MANUFACTURER?S LARGEST STANDARD SIZE | | | WINDOW THAT WILL FIT WITHIN THE EXISTING FRAME OR | | | EXISTING ROUGH OPENING. THE REPLACEMENT WINDOW SHALL BE | | | PERMITTED TO BE OF THE SAME OPERATING STYLE AS THE | | | EXISTING WINDOW OR A STYLE THAT PROVIDES FOR AN EQUAL | | | OR GREATER WINDOW OPENING AREA THAN THE EXISTING | | | WINDOW. | | | WINDOW OPENING CONTROL DEVICES COMPLYING WITH ASTM | | | F2090 SHALL BE PERMITTED FOR USE ON WINDOWS REQUIRED TO | | | PROVIDE EMERGENCY ESCAPE AND RESCUE OPENINGS. | | | | | | | | | 7- CLEARLY IDENTIFY ON PLANS IF ANY SECOND FLOOR WINDOW | | | WILL NEED WINDOW OPENING CONTROL DEVICES AS REQUIRED BY | | | SEE SEC. 702.4 FBC-EXISTING BUILDING CODE. WINDOW | | | OPENING CONTROL DEVICES IN WINDOW REPLACEMENT ARE | | | REQUIRED WHEN THE FOLLOWING APPLY: | | | | | | 702.4 WINDOW OPENING CONTROL DEVICES. | | | | | | IN GROUP R-2 OR R-3 BUILDINGS CONTAINING DWELLING UNITS | | | AND ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES | | | REGULATED BY THE FLORIDA BUILDING CODE, RESIDENTIAL, | | | WINDOW OPENING CONTROL DEVICES COMPLYING WITH ASTM | | | F2090 SHALL BE INSTALLED WHERE AN EXISTING WINDOW IS | | | REPLACED AND WHERE ALL OF THE FOLLOWING APPLY TO THE | | | REPLACEMENT WINDOW: | | | 1.THE WINDOW IS OPERABLE; | | | 2. THE WINDOW REPLACEMENT INCLUDES REPLACEMENT OF THE | | | SASH AND THE FRAME; | | | 3.ONE OF THE FOLLOWING APPLIES: | | | 3.1.IN GROUP R-2 OR R-3 BUILDINGS CONTAINING DWELLING | | | UNITS, THE TOP OF THE SILL OF THE WINDOW OPENING IS AT | | | A HEIGHT LESS THAN 36 INCHES (915 MM) ABOVE THE | | | FINISHED FLOOR; OR | | | 3.2. IN ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES | | | REGULATED BY THE FLORIDA BUILDING CODE, RESIDENTIAL, | | | THE TOP SILL OF THE WINDOW OPENING IS AT A HEIGHT LESS | | | THAN 24 INCHES (610 MM) ABOVE THE FINISHED FLOOR; | | | 4.THE WINDOW WILL PERMIT OPENINGS THAT WILL ALLOW | | | PASSAGE OF A 4-INCH-DIAMETER (102 MM) SPHERE WHEN THE | | | WINDOW IS IN ITS LARGEST OPENED POSITION; AND | | | 5.THE VERTICAL DISTANCE FROM THE TOP OF THE SILL OF THE | | | WINDOW OPENING TO THE FINISHED GRADE OR OTHER SURFACE | | | BELOW, ON THE EXTERIOR OF THE BUILDING, IS GREATER THAN | | | 72 INCHES (1829 MM). | | | THE WINDOW OPENING CONTROL DEVICE, AFTER OPERATION TO | | | RELEASE THE CONTROL DEVICE ALLOWING THE WINDOW TO FULLY | | | OPEN, SHALL NOT REDUCE THE MINIMUM NET CLEAR OPENING | | | AREA OF THE WINDOW UNIT TO LESS THAN THE AREA REQUIRED | | | BY THE FLORIDA BUILDING CODE, BUILDING. | | | | | | EXCEPTIONS: | | | 1.OPERABLE WINDOWS WHERE THE TOP OF THE SILL OF THE | | | WINDOW OPENING IS LOCATED MORE THAN 75 FEET (22 860 MM) | | | ABOVE THE FINISHED GRADE OR OTHER SURFACE BELOW, ON THE | | | EXTERIOR OF THE ROOM, SPACE OR BUILDING, AND THAT ARE | | | PROVIDED WITH WINDOW FALL PREVENTION DEVICES THAT | | | COMPLY WITH ASTM F2006. | | | 2.OPERABLE WINDOWS WITH OPENINGS THAT ARE PROVIDED WITH | | | WINDOW FALL PREVENTION DEVICES THAT COMPLY WITH ASTM | | | F2090. | | | | | | 8- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL) | | | A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. NOTE: | | | IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | B) ALL EXTERIOR DOORS AS SHOWN ON PLANS. | | | | | | C) ALL SINGLE HUNG WINDOWS AS SHOWN ON PLANS. | | | | | | D) ALL FIXED WINDOWS AS SHOWN ON PLANS. | | | | | | E) WINDOW MULLIONS AS SHOWN ON PLANS. AND, CLEARLY MARK | | | MULLION SIZE TO VERIFY COMPLIANCE WITH THE CALCULATED | | | DESIGN PRESSURES. | | | | | | F) HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE | | | IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE CITY SAMPLE. | | | | | | G) ALL STRUCTURAL CONNECTORS (FOR EXAMPLE SIMPSON | | | CONNECTORS) SPECIFIED ON PLANS AND DETAILS. NOTE: | | | PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL COVER PAGE | | | AND PAGE SHOWING THE SPECIFIED CONNECTOR OR DESIGN | | | PROFESSIONAL TO LIST THE FLORIDA PRODUCT APPROVAL | | | NUMBER NEXT TO EACH SPECIFIED CONNECTOR. | | | | | | 9- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 10- SIZE AND TYPE OF WINDOWS SHOWN IN THE WINDOW | | | SCHEDULE ARE NOT CLEAR. SEC. 107.2.1 CITY AMENDMENTS. | | | WINDOW W-1 IS NOT CLEAR IF IT'S A SINGLE HUNG WINDOW OR | | | FIXED WINDOW. TYPICALLY A SH35 SINGLE HUNG WINDOW | | | DOESN'T HAVE A 26-1/2" WIDTH (COORDINATE SIZE WITH | | | WINDOW MANUFACTURER). | | | | | | 11- THERE ARE A LOT OF TYPOS IN THE WINDOW SCHEDULE | | | NOTES AND TERMITE PROTECTION NOTES. PLEASE REVISE AS | | | REQUIRED TO AVOID CONFLICTS. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | | | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | | REVIEWED DRAWINGS. DO NOT STAPLE OLD DRAWINGS TO PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2019-01-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-25 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-25 |
Time |
15:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-01-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-15 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-14 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2019-01-15 11:31:37 | ELECTRICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. CORRECTED. | | | | | | NEW COMMENTS: | | | | | | 3. A MINIMUM OF TWO SMALL APPLIANCE BRANCH CIRCUITS | | | SHALL BE INSTALLED FOR KITCHEN COUNTER TOP RECEPTACLES. | | | PROVIDE CORRECTION. NEC 210.11(C)(1) , FBC RE E3703.2 | | | 4. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. THE SQUARE FOOTAGE CALCULATION ON | | | PLAN IS ONLY FOR 393 SQUARE FEET, WHICH DOES NOT AGREE | | | WITH THE SQUARE FOOTAGE SHOWN ON PBC PAPA. NEC 215.2, | | | 220, 408.30; FBC RE E3602.2 | | | 5. ONLY ONE SERVICE PER RESIDENTIAL ADDRESS IS | | | PERMITTED. PROVIDE CORRECTION AND/OR CLARIFICATION. WPB | | | FBC 107.2.1; NEC 230.2; FBC RE E3601.2 | | | 6. IF NEW SERVICE IS PROPOSED, PROVIDE DETAILS OF | | | EXISTING AND PROPOSED. PROVIDE AVAILABLE SHORT CIRCUIT | | | CALCULATION FOR EACH PANEL INCLUDING INFORMATION FROM | | | THE POWER COMPANY STATING WHAT THE AVAILABLE SHORT | | | CIRCUIT CURRENT IS FOR THE SERVICE TO CONFIRM THE | | | STATED AIC RATING OF THE SERVICE EQUIPMENT AND | | | DOWNSTREAM PANELS IS ADEQUATE. NEC 110.9, 110.10; FBC | | | RE E3606.3 | | | 7. A SMOKE ALARM IS REQUIRED ON EACH LEVEL OF THE | | | DWELLING UNIT. PROVIDE CORRECTION. FBC RE R314.3 | | | 8. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902; | | | FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE. | | | 9. GFCI PROTECTION IS REQUIRED FOR ALL EXTERIOR | | | RECEPTACLE OUTLETS. PROVIDE CORRECTION. NEC 210.8; FBC | | | RE E3902.3 | | | 10. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 11. THERE APPEARS TO BE SOMETHING LOCATED IN FRONT OF | | | ELECTRICAL PANEL. CLEARANCE IN FRONT OF THE PANEL IS | | | REQUIRED. PROVIDE CORRECTION.NEC 110.26; FBC RE E3405.1 | | | 12. PROVIDE LOCATION OF ELECTRICAL SERVICE ON PLAN. WPB | | | FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-12-20 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-12-20 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-12-20 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2019-01-02 15:23:09 | CONTRACT EMAILED, VALUE IS CORRECT. 1/2/19 | | | | | | | | 2018-12-20 08:48:03 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. FBC 109.3 | | | (NOT PROVIDED) | | | 2. CORRECTED. | | | | | | NEW COMMENTS: | | | | | | 3. A MINIMUM OF TWO SMALL APPLIANCE BRANCH CIRCUITS | | | SHALL BE INSTALLED FOR KITCHEN COUNTER TOP RECEPTACLES. | | | PROVIDE CORRECTION. NEC 210.11(C)(1) , FBC RE E3703.2 | | | 4. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. THE SQUARE FOOTAGE CALCULATION ON | | | PLAN IS ONLY FOR 393 SQUARE FEET, WHICH DOES NOT AGREE | | | WITH THE SQUARE FOOTAGE SHOWN ON PBC PAPA. NEC 215.2, | | | 220, 408.30; FBC RE E3602.2 | | | 5. ONLY ONE SERVICE PER RESIDENTIAL ADDRESS IS | | | PERMITTED. PROVIDE CORRECTION AND/OR CLARIFICATION. WPB | | | FBC 107.2.1; NEC 230.2; FBC RE E3601.2 | | | 6. IF NEW SERVICE IS PROPOSED, PROVIDE DETAILS OF | | | EXISTING AND PROPOSED. PROVIDE AVAILABLE SHORT CIRCUIT | | | CALCULATION FOR EACH PANEL INCLUDING INFORMATION FROM | | | THE POWER COMPANY STATING WHAT THE AVAILABLE SHORT | | | CIRCUIT CURRENT IS FOR THE SERVICE TO CONFIRM THE | | | STATED AIC RATING OF THE SERVICE EQUIPMENT AND | | | DOWNSTREAM PANELS IS ADEQUATE. NEC 110.9, 110.10; FBC | | | RE E3606.3 | | | 7. A SMOKE ALARM IS REQUIRED ON EACH LEVEL OF THE | | | DWELLING UNIT. PROVIDE CORRECTION. FBC RE R314.3 | | | 8. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902; | | | FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE. | | | 9. GFCI PROTECTION IS REQUIRED FOR ALL EXTERIOR | | | RECEPTACLE OUTLETS. PROVIDE CORRECTION. NEC 210.8; FBC | | | RE E3902.3 | | | 10. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | 11. THERE APPEARS TO BE SOMETHING LOCATED IN FRONT OF | | | ELECTRICAL PANEL. CLEARANCE IN FRONT OF THE PANEL IS | | | REQUIRED. PROVIDE CORRECTION.NEC 110.26; FBC RE E3405.1 | | | 12. PROVIDE LOCATION OF ELECTRICAL SERVICE ON PLAN. WPB | | | FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-10-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-26 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-26 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2018-10-26 13:05:59 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. FBC 109.3 | | | 2. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | | SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. WPB | | | FBC 107.2.1, 107.3.5; FS 471, 481 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-01-10 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-01-10 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-01-10 |
Time |
09:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-12-14 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-12-14 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-12-14 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2018-12-14 11:22:12 | PROPERTY LOXCATE DIN HSITORIC DISTRICT. ADDITIONS | | | REQUIRE SUBMITTAL FO A COA. WINDOWS DO NOT MEET DESIGN | | | GUIDELINES.....SHALL BE S/H ALUMINUM WITH GRID PATTERN | | | TO MATCH EXISITNG HOUSE. QUESTIONS, CONTACT FRIEDERIKE | | | MITTNER, CITY HISITORIC PRESERVATION PLANNER AT (561) | | | 822-1457 OR [email protected] |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-10-25 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-10-25 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-10-25 |
Time |
15:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-01-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-25 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-23 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2019-01-24 15:58:44 | RESUB ROUTED TO CTHROOP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-01-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-15 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-03 |
Time |
14:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-12-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-31 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-04 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-11-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-11-15 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-10-05 |
Time |
15:06 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-12-21 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-12-21 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-10-27 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-10-27 |
Time |
06:00 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-10-27 |
Time |
05:58 |
Sent To |
|
|
| Notes |
| 2018-10-27 06:00:25 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1 - NEED MECHANICAL PLANS PER 2017 FLORIDA BUILDING | | | CODE - BUILDING, SIXTH EDITION 107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS | | | | | | | | | CHRIS MONTELLO | | | 561-805-6733 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-12-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-31 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-31 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2018-11-06 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-11-06 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-11-06 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2018-11-06 12:36:29 | THERE APPEARS TO BE NO PLUMBING IN THE SCOPE OF WORK.A | | | PLUMBING PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A PLUMBING PLAN REVIEW HAS NOT BEEN PERFORMED | | | AT THIS TIME. A SEPARATE PLUMBING PERMIT AND PLANS WILL | | | BE REQUIRED FOR A CONTRACTOR TO PERFORM ANY RELATED | | | WORK. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL: [email protected] | | | PHONE: 561-805-6715 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2019-01-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-25 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-25 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2019-01-25 15:43:08 | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | | | | PROVISO | | | | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON | | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | | OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2019-01-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-01-15 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-14 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2019-01-15 11:28:59 | BUILDING PLAN REVIEW - ROOFING | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOF SYSTEM. | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | PROVISO | | | | | | 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON | | | THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING | | | OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-12-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-31 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-31 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2018-12-31 13:12:38 | | | | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR ROOF SYSTEM | | | COMPONENETS. | | | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-11-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-11-15 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-11-15 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2018-11-15 09:53:55 | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.001 FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL) | | | A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. NOTE: | | | IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-01-10 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-01-10 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-01-10 |
Time |
09:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2018-12-14 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-12-14 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-12-14 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2018-12-14 11:22:55 | REQUIRES SUBMITTAL FO LOT COVERAGE AND FAR CALCS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-10-25 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-10-25 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-10-25 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
|