Plan Review Details - Permit 18100245
Plan Review Stops For Permit 18100245
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-02-22 Cont ID  
Sent By jgomez Date 2019-02-22 Time 17:20 Rev Time 0.00
Received By jgomez Date 2019-02-22 Time 16:12 Sent To  
Notes
2019-02-22 17:22:56BUILDING REVIEW APPROVED WITH PROVISO:
 1- REVISE ENERGY CALCULATIONS: DOORS INFORMATION ON
 PAGE 3 OF 4 IS INCORRECT. THERE ARE NO WOO DOORS ON THE
 EXTERIOR WALL.
  
 NOTE:
 LABEL FOR WINDOWS AND DOORS SHOWING THE SHGC FACTOR
 SPECIFIED IN THE ENERGY CALCULATIONS WILL BE REQUIRED
 FOR INSPECTION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-01-31 Cont ID  
Sent By jgomez Date 2019-01-31 Time 11:35 Rev Time 0.00
Received By jgomez Date 2019-01-30 Time 18:29 Sent To  
Notes
2019-01-31 11:36:27RESIDENTIAL (R3)ALTERATION/ADDITION SECOND REVIEW
 CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- IMPACT FEES - CONVERSION OF PORCH TO BEDROOM. PLANS
 REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL (561)
 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN SET
 AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED
 STAMPED AND WITH A COPY OF THE RECEIPT AS APPLICABLE.
 PLEASE PROVIDE THE MUNICIPAL IMPACT FEE QUESTIONNAIRE
 FORM TO THE PBC IMPACT FEE OFFICE. THE FORM CAN BE
 FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRATION
 /PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 RESPONSE:
 NEED TO PROVIDE COPY OF PAID RECEIPT ALSO. ONLY THE
 COUNTY STAMPED PLAN WAS SUBMITTED.
  
  
 ORIGINAL COMMENT:
 2- NONE OF THE WINDOWS OF THE NEW BEDROOM COMPLY WITH
 THE EGRESS REQUIREMENTS. OF SEC. R310.2.1
 FBC-RESIDENTIAL. REVISE AS REQUIRED TO COMPLY.
  
 RESPONSE:
 REPEAT COMMENT. 36"X52" S.H . WINDOWS DON'T COMPLY WITH
 EGRESS REQUIREMENTS. THIS WINDOW SIZE DOESN'T COMPLY
 WITH THE MIN. CLEAR HEIGHT. EGRESS WINDOWS NEED TO
 COMPLY WITH ALL CLEAR DIMENSIONS FOR WIDTH, HEIGHT AND
 TOTAL OPENING AREA. SEE SEC. R310.2.1 FBC-RESIDENTIAL.
  
 3- OK.
  
 4- OK.
  
 5- OK.
  
 6- WALL SECTION 2/A-1:
 A) OK.
  
 ORIGINAL COMMENT:
 B) SPECIFY ROOF CROSS VENTILATION AS REQUIRED BY SEC.
 R806.1 AND R806.2 FBC-RESIDENTIAL.
 NOTE: ONLY CONTINUOUS VENT WILL PROVIDE CROSS
 VENTILATION. ALSO, COORDINATE WITH THE ENERGY
 CALCULATIONS. NEED 1/150 VENT RATIO. SEE COMMENTS ON
 ENERGY CALCULATIONS.
  
 RESPONSE:
 DESIGNER OF RECORD NEEDS TO SPECIFY SIZE OF CONTINUOUS
 VENTILATION.
  
 C)OK.
  
 ORIGINAL COMMENT:
 D) SHOW THE 6" MIN. CLEARANCE FOR TERMITE INSPECTION AS
 REQUIRED BY SEC. R318.7 FBC-RESIDENTIAL.
  
 RESPONSE:
 SEE SEC. R318.7. NEED TO SPECIFY THE 6" CLEARANCE
 BETWEEN THE EXTERIOR WALL COVERING AND FINAL EARTH
 GRADE.
  
 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 A) OK.
  
 B)OK.
  
 8- OK.
  
 9- ENERGY CALCULATIONS:
 A) OK.
  
 B) OK.
  
 C)OK.
  
 D)OK.
  
 E)
  
 F) OK.
  
 G) OK.
  
 ORIGINAL COMMENT:
 H) ITEM #15 ON PAGE 1 OF 5 IS TAKEN THE CEILING FAN AND
 WHOLE HOUSE FAN OPTION. PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS SHOWING HOW THE HOSE COMPLIES WITH BOTH
 CREDITS. SEE SEC. R405.7.5 AND SEC. R405.7.6 FBC-ENERGY
 CONSERVATION FOR SPECIFIC REQUIREMENTS.
  
 RESPONSE:
 ENERGY CALCULATIONS ARE NOW TAKING THE CROSS
 VENTILATION CREDIT. IT LOOKS LIKE THE ADDITION DOESN'T
 COMPLY WITH THE REQUIREMENTS OF SEC. R405.7.4
 FBC-ENERGY CONSERVATION. SEE ITEM 1 OF SEC. R405.7.4.
 REVISE AS REQUIRED.
  
 ORIGINAL COMMENT:
 I) SPACES SHOWN ON PAGE 2 OF 5 ARE NOT CLEAR. FLOOR
 PLANS DON'T SHOW ANY SUNSPACE, NUMBER OF BEDROOMS IS
 NOT CLEAR. COORDINATE WITH ITEM #3 ABOVE. SEC.
 R101.5.1.1.2 FBC-RESIDENTIAL.
  
 RESPONSE:
 ENERGY CALCULATIONS WERE REVISED TO SHOW COMPLIANCE
 ONLY FOR THE BEDROOM ADDITION. REVISED CALCULATIONS
 SPECIFY THAT THERE IS A KITCHEN IN THE BEDROOM. THIS IS
 INCORRECT. REVISE AS REQUIRED.
  
 ORIGINAL COMMENT:
 J) ENGINEER PREPARING THE ENERGY CALCULATIONS TO
 PROVIDE HIS INFORMATION AS REQUIRED BY CHAPTER 471 F.S.
 AND 61G15-23.001 FAC WHEN SUBMITTING DOCUMENTS FOR
 PUBLIC RECORDS.
  
 RESPONSE:
 FRONT PAGE WHERE ENGINEER SIGNED AND PROVIDED HIS NAME
 IS MISSING THE ENGINEER'S LICENSE NUMBER.
  
 K)OK.
  
 ORIGINAL COMMENT:
 L)DOORS INFORMATION ON PAGE 3 OF 5 IS NO CLEAR. SHOW ON
 PLANS THE SPECIFIED WOOD DOORS. SEC. R101.5.1.1.2
 FBC-RESIDENTIAL.
 NOTE: DOORS TO BE CONSIDERED ARE ONLY FOR EXTERIOR
 DOORS OR THE DOORS SEPARATING THE NON-A/C AREAS TO A/C
 AREAS.
  
 RESPONSE:
 THERE ARE NOT EXTERIOR DOORS IN THE BEDROOM ADDITION.
 REVISE AS REQUIRED. THE DOOR FROM THE BEDROOM TO THE
 REST OF THE HOUSE IS WITHIN A/C AREA. NO NEED TO
 INCLUDE IT. THIS AREA IS NOT PART OF THE EXTERIOR
 ENVELOPE. REVISE AS REQUIRED.
  
 ORIGINAL COMMENT:
 M) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 COMPLIANCE WITH THE EXCEPTION OF SEC. R806.2
 FBC-RESIDENTIAL WHEN SPECIFYING A VENT RATIO OF 1/300
 AS SHOWN ON PAGE 3 OF 5.
  
 RESPONSE:
 VENTILATION SHOWN ON PLANS DON'T COMPLY WITH THE
 REQUIREMENTS OF THE EXCEPTION TO SEC. R806.2
 FBC-RESIDENTIAL. REVISE AS REQUIRED.
  
 NOTE:
 LABEL FOR WINDOWS AND DOORS SHOWING THE SHGC FACTOR
 SPECIFIED IN THE ENERGY CALCULATIONS WILL BE REQUIRED
 FOR INSPECTION.
  
 10- OK.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-11-20 Cont ID  
Sent By jgomez Date 2018-11-20 Time 16:39 Rev Time 0.00
Received By jgomez Date 2018-11-20 Time 13:08 Sent To  
Notes
2018-11-20 16:40:14RESIDENTIAL (R3)ALTERATION/ADDITION BUILDING REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- IMPACT FEES - CONVERSION OF PORCH TO BEDROOM. PLANS
 REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL (561)
 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN SET
 AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED
 STAMPED AND WITH A COPY OF THE RECEIPT AS APPLICABLE.
 PLEASE PROVIDE THE MUNICIPAL IMPACT FEE QUESTIONNAIRE
 FORM TO THE PBC IMPACT FEE OFFICE. THE FORM CAN BE
 FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRATION
 /PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 2- NONE OF THE WINDOWS OF THE NEW BEDROOM COMPLY WITH
 THE EGRESS REQUIREMENTS. OF SEC. R310.2.1
 FBC-RESIDENTIAL. REVISE AS REQUIRED TO COMPLY.
  
 3- IDENTIFY NEW ROOM THAT IS HAVING A NEW POCKET DOOR
 AND IS LOCATED NEXT TO THE KITCHEN AREA. SEC. 107.2.1
 CITY AMENDMENTS. IF BEDROOM , THEN PROVIDE COMPLIANCE
 WITH EGRESS REQUIREMENTS.
 NOTE: CLEARLY IDENTIFY ALL ROOM AREAS IN FLOOR PLAN
 SUBMITTED. COORDINATE WITH ENERGY CALCULATIONS. SEE
 ITEM #9(I) OF ENERGY CALCULATIONS COMMENTS.
  
 4- MECHANICAL PLANS ON SHEET E-M SPECIFIES SHOWS
 REMOVAL OF WINDOW IN EXITING BATHROOM. SHOW COMPLIANCE
 WITH THE BATHROOM LIGHT AND VENTILATION AS REQUIRED BY
 SEC. R303.3 FBC-RESIDENTIAL.
  
 5- PLANS TO SHOW COMPLIANCE WITH THE HEATING
 REQUIREMENTS FOR NEW BEDROOM AS REQUIRED BY SEC.
 R303.10 FBC-RESIDENTIAL.
  
 6- WALL SECTION 2/A-1:
 A) CLEARLY SPECIFY ALL FRAMING MEMBERS AND CONNECTORS
 (EXISTING AND NEW) SHOWING THE LOAD PATH FROM ROOF TO
 FOUNDATION AS REQUIRED BY SEC. R601.2 FBC-RESIDENTIAL
 AND SEC. 801.3 FBC-EXISTING BUILDING.
 NOTE: CHANGE OF USE OF THE SPACE FROM NON-HABITABLE
 AREA TO HABITABLE AREA REQUIRES AREA TO COMPLY WITH ALL
 THE REQUIREMENTS OF THE FBC-RESIDENTIAL.
  
 B) SPECIFY ROOF CROSS VENTILATION AS REQUIRED BY SEC.
 R806.1 AND R806.2 FBC-RESIDENTIAL.
 NOTE: ONLY CONTINUOUS VENT WILL PROVIDE CROSS
 VENTILATION. ALSO, COORDINATE WITH THE ENERGY
 CALCULATIONS. NEED 1/150 VENT RATIO. SEE COMMENTS ON
 ENERGY CALCULATIONS.
  
 C)WALL SECTION CALLS FOR MIN. R30 CEILING INSULATION.
 SPECIFY TYPE OF INSULATION. NOTE: KEEP IN MIND THAT
 BATT INSULATION IS 9-1/2" THICK +/-. AND, ALSO NEED AT
 LEAST 1 INCH CLEARANCE FOR ROOF VENTILATION. ALSO,
 COORDINATE WITH ENERGY CALCULATIONS TO AVOID CONFLICTS.
  
 D) SHOW THE 6" MIN. CLEARANCE FOR TERMITE INSPECTION AS
 REQUIRED BY SEC. R318.7 FBC-RESIDENTIAL.
  
 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 A) SINGLE HUNG WINDOWS. DRAWINGS SUBMITTED WITH FLORIDA
 PRODUCT APPROVAL FL14911-R10 ARE NOT LEGIBLE. THEY ARE
 CUT. PROVIDE PAGES WITH COMPLETE DRAWINGS.
  
 B)ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS
 AND DETAILS. NOTE: PROVIDE ONLY THE FLORIDA PRODUCT
 APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED
 CONNECTOR OR DESIGN PROFESSIONAL TO LIST THE FLORIDA
 PRODUCT APPROVAL NUMBER NEXT TO EACH SPECIFIED
 CONNECTOR.
  
 8- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 9- ENERGY CALCULATIONS:
 A) THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED
 AND DATED BY THE OWNER OR OWNER?S LEGALLY DESIGNATED
 AGENT AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY
 CONSERVATION, 6TH EDITION (2017).
  
 B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING THE BUILDER'S NAME, PERMIT OFFICE AND
 JURISDICTION SEC. R101.5.1.1.2 FBC- ENERGY
 CONSERVATION.
  
 C)NUMBER OF BEDROOMS IS INCORRECT. REVISE ITEM #4 ON
 PAGE 1 OF 5. SEC. R101.5.1.1.2 FBC-RESIDENTIAL.
  
 D)CONDITIONED FLOOR AREA ON ITEM #6 ON PAGE 1 OF 5
 SEEMS TO BE INCORRECT. CLARIFY WHY THE AREAS DON'T
 MATCH AREAS SHOWN ON THE PROPERTY APPRAISER WEBSITE IF
 THE FOOTPRINT SEEMS TO BE THE SAME. SEC. R101.5.1.1.2
 FBC-RESIDENTIAL.
  
 E)PROVIDE WINDOWS AND DOORS MANUFACTURER'S
 SPECIFICATIONS SHOWING THE U-FACTOR AND SHGC FACTOR
 SPECIFIED ON THE ENERGY CALCULATIONS ON ITEM #7 ON PAGE
 1 OF 5 AS REQUIRED BY SEC. R405.4.3 FBC-ENERGY
 CONSERVATION. NOTE: COORDINATE WITH PLANS AND PRODUCT
 APPROVALS SUBMITTED TO AVOID CONFLICTS/DELAYS.
  
 F) PROVIDE SPECIFICATIONS SHOWING THE SLAB ON GRADE
 EDGE INSULATION SOWN ON ITEM #8 ON PAGE 1 OF 5. SEC.
 R101.5.1.1.2 FBC-RESIDENTIAL.
  
 G) ITEM #10 ON PAGE 1 OF 5 SPECIFIES R-30 CEILING
 INSULATION. PROVIDE SPECIFICATIONS FOR R-30 INSULATION
 IN THE NEW BEDROOM WITH A FLAT ROOF. NOTE: COORDINATE
 WITH ITEM #6(B) AND 6(C) ABOVE TO AVOID CONFLICTS. SEC.
 R101.5.1.1.2 FBC-RESIDENTIAL.
  
 H) ITEM #15 ON PAGE 1 OF 5 IS TAKEN THE CEILING FAN AND
 WHOLE HOUSE FAN OPTION. PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS SHOWING HOW THE HOSE COMPLIES WITH BOTH
 CREDITS. SEE SEC. R405.7.5 AND SEC. R405.7.6 FBC-ENERGY
 CONSERVATION FOR SPECIFIC REQUIREMENTS.
  
 I) SPACES SHOWN ON PAGE 2 OF 5 ARE NOT CLEAR. FLOOR
 PLANS DON'T SHOW ANY SUNSPACE, NUMBER OF BEDROOMS IS
 NOT CLEAR. COORDINATE WITH ITEM #3 ABOVE. SEC.
 R101.5.1.1.2 FBC-RESIDENTIAL.
  
 J) ENGINEER PREPARING THE ENERGY CALCULATIONS TO
 PROVIDE HIS INFORMATION AS REQUIRED BY CHAPTER 471 F.S.
 AND 61G15-23.001 FAC WHEN SUBMITTING DOCUMENTS FOR
 PUBLIC RECORDS.
  
 K) ROOF MATERIAL SPECIFIED ON PAGE 3 OF 5 DOESN'T MATCH
 MATERIALS IN THIS HOUSE. MAIN HOUSE IS CONCRETE TILE
 AND NEW BEDROOM IS FLAT ROOF. REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-RESIDENTIAL.
  
 L)DOORS INFORMATION ON PAGE 3 OF 5 IS NO CLEAR. SHOW ON
 PLANS THE SPECIFIED WOOD DOORS. SEC. R101.5.1.1.2
 FBC-RESIDENTIAL.
 NOTE: DOORS TO BE CONSIDERED ARE ONLY THE DOORS
 SEPARATING THE NON-A/C AREAS
  
 M) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 COMPLIANCE WITH THE EXCEPTION OF SEC. R806.2
 FBC-RESIDENTIAL WHEN SPECIFYING A VENT RATIO OF 1/300
 AS SHOWN ON PAGE 3 OF 5.
  
 NOTE:
 LABEL FOR WINDOWS AND DOORS SHOWING THE SHGC FACTOR
 SPECIFIED IN THE ENERGY CALCULATIONS WILL BE REQUIRED
 FOR INSPECTION.
  
 10- - VALUATION DECLARED IN THE PERMIT APPLICATION IS
 TOO LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. UPDATE VALUATION OR PROVIDE COPY OF SIGNED
 CONTRACTS, INCLUDING DESIGN PROFESSIONAL FEES.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-01-31 Cont ID  
Sent By jpearson Date 2019-01-31 Time 14:04 Rev Time 0.00
Received By jpearson Date 2019-01-31 Time 14:04 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-10-29 Cont ID  
Sent By jpearson Date 2018-10-29 Time 16:09 Rev Time 0.00
Received By jpearson Date 2018-10-29 Time 15:21 Sent To  
Notes
2018-10-29 16:09:07CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. AFCI PROTECTION SHOWN IN NOT CODE COMPLIANT. ALL
 BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15-
 AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY
 ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES,
 DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS,
 HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS
 SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND
 POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH
 AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC
 210.8, 210.12; FBC RE E3902; FBC EX 607.1.1 OR 801.1,
 801.2, OR 901.2 AS APPLICABLE.
 2. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5,
 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902
 3. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS
 IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. FBC 109.3
 4. NOTE STATES THAT RECEPTACLES SHALL BE TAMPER
 RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT
 APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE
 CORRECTION. NEC 406.12; FBC RE E4002.14
 5. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP
 CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN.
 PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52(D); FBC RE
 E3703.4, E3901.6
 6. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED
 PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING
 ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS
 NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC
 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-02-22 Cont ID  
Sent By jgomez Date 2019-02-22 Time 17:35 Rev Time 0.00
Received By jgomez Date 2019-02-15 Time 13:44 Sent To I
Notes
2019-02-19 13:44:33RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2019-01-31 Time   Rev Time 0.00
Received By lmarchan Date 2019-01-14 Time 15:15 Sent To  
Notes
2019-01-15 15:15:13R05

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-11-20 Cont ID  
Sent By jgomez Date 2018-11-20 Time 17:10 Rev Time 0.00
Received By jgomez Date 2018-10-04 Time 13:42 Sent To I
Notes
2018-10-11 16:21:37R22
2018-10-05 13:42:39LIBRARY

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2019-02-22 Cont ID  
Sent By jgomez Date 2019-02-22 Time 16:43 Rev Time 0.00
Received By jgomez Date 2019-02-22 Time 16:43 Sent To  
Notes
2019-02-22 16:45:02$180.65 PAID. MU-2018-039757.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2019-01-31 Cont ID  
Sent By jgomez Date 2019-01-31 Time 11:36 Rev Time 0.00
Received By jgomez Date 2019-01-31 Time 11:36 Sent To  
Notes
2019-01-31 11:36:481- IMPACT FEES - CONVERSION OF PORCH TO BEDROOM. PLANS
 REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL (561)
 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN SET
 AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED
 STAMPED AND WITH A COPY OF THE RECEIPT AS APPLICABLE.
 PLEASE PROVIDE THE MUNICIPAL IMPACT FEE QUESTIONNAIRE
 FORM TO THE PBC IMPACT FEE OFFICE. THE FORM CAN BE
 FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRATION
 /PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 RESPONSE:
 NEED TO PROVIDE COPY OF PAID RECEIPT ALSO. ONLY THE
 COUNTY STAMPED PLAN WAS SUBMITTED.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-11-20 Cont ID  
Sent By jgomez Date 2018-11-20 Time 14:14 Rev Time 0.00
Received By jgomez Date 2018-11-20 Time 14:06 Sent To  
Notes
2018-11-20 14:14:161- IMPACT FEES - CONVERSION OF PORCH TO BEDROOM. PLANS
 REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL (561)
 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN SET
 AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED
 STAMPED AND WITH A COPY OF THE RECEIPT AS APPLICABLE.
 PLEASE PROVIDE THE MUNICIPAL IMPACT FEE QUESTIONNAIRE
 FORM TO THE PBC IMPACT FEE OFFICE. THE FORM CAN BE
 FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRATION
 /PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-01-25 Cont ID  
Sent By cmontell Date 2019-01-25 Time 14:44 Rev Time 0.00
Received By cmontell Date 2019-01-25 Time 14:38 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-10-27 Cont ID  
Sent By cmontell Date 2018-10-27 Time 06:19 Rev Time 0.00
Received By cmontell Date 2018-10-27 Time 06:14 Sent To  
Notes
2018-10-27 06:19:41MECHANICAL PLAN FAIL
  
  
 1 - NO DUCT WORK ON MECHANICAL PLAN
  
  
 CHRIS MONTELLO
 561-805-6733

Review Stop Z ZONING
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2019-01-29 Time   Rev Time 0.00
Received By pgreilic Date 2019-01-29 Time 14:18 Sent To  
Notes
2019-01-29 14:19:00PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2018-11-19 Cont ID  
Sent By pgreilic Date 2018-11-19 Time 10:41 Rev Time 0.00
Received By pgreilic Date 2018-11-19 Time 10:36 Sent To  
Notes
2018-11-19 10:42:121.) PROVIDE A SITE PLAN OR SURVEY AND LABEL SETBACKS,
 SHADE AREA OF WORK ON SURVEY/SITE PLAN
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]


Account Summary | Usage Policy | Privacy Policy