| Plan Review Stops For Permit 18100224 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-12-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-17 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-17 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-12-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-03 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-03 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2018-12-03 15:06:25 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1. 1ST BLDG. REVIEW COMMENTS HAVE BEEN ADDRESSED. | | | 2. NEW PLAN SHEETS WILL BE REQUIRED PER ENGINEERING | | | COMMENTS. | | | 3. ADDRESS ENGINEERING COMMENTS AND RE-SUBMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-10-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-10-24 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-10-24 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2018-10-24 11:22:49 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | ACCESSIBLE PARKING | | | | | | PROVIDE A LEGIBLE PLAN TO PROVIDE THE FOLLOWING | | | INFORMATION PER 208.2 | | | TOTAL NUMBER OF PARKING SPACES | | | NUMBER OF ACCESSIBLE SPACES | | | LOCATION OF ACCESSIBLE ENTRANCES | | | LOCATION OF ACCESSIBLE SPACES AND ACCESS AISLES | | | SHOW ACCESSIBLE ROUTE FROM PUBLIC WAY | | | ACCESSIBLE ROUTE FROM ACCESSIBLE SPACE TO ACCESSIBLE | | | ENTRANCE | | | | | | 206.2.1SITE ARRIVAL POINTS. | | | AT LEAST ONE ACCESSIBLE ROUTE SHALL BE PROVIDED WITHIN | | | THE SITE FROM ACCESSIBLE PARKING SPACES AND ACCESSIBLE | | | PASSENGER LOADING ZONES; PUBLIC STREETS AND SIDEWALKS; | | | AND PUBLIC TRANSPORTATION STOPS TO THE ACCESSIBLE | | | BUILDING OR FACILITY ENTRANCE THEY SERVE | | | | | | 208.1 GENERAL. | | | WHERE PARKING SPACES ARE PROVIDED, PARKING SPACES SHALL | | | BE PROVIDED IN ACCORDANCE WITH 208. SEE SECTION 502.5 | | | REQUIREMENTS FOR VAN PARKING IN STRUCTURES. | | | | | | EXCEPTION: PARKING SPACES USED EXCLUSIVELY FOR BUSES, | | | TRUCKS, OTHER DELIVERY VEHICLES, LAW ENFORCEMENT | | | VEHICLES, OR VEHICULAR IMPOUND SHALL NOT BE REQUIRED TO | | | COMPLY WITH 208 PROVIDED THAT LOTS ACCESSED BY THE | | | PUBLIC ARE PROVIDED WITH A PASSENGER LOADING ZONE | | | COMPLYING WITH 503. | | | | | | 208.2 MINIMUM NUMBER. | | | PARKING SPACES COMPLYING WITH 502 SHALL BE PROVIDED IN | | | ACCORDANCE WITH TABLE 208.2 EXCEPT AS REQUIRED BY | | | 208.2.1, 208.2.2, AND 208.2.3. WHERE MORE THAN ONE | | | PARKING FACILITY IS PROVIDED ON A SITE, THE NUMBER OF | | | ACCESSIBLE SPACES PROVIDED ON THE SITE SHALL BE | | | CALCULATED ACCORDING TO THE NUMBER OF SPACES REQUIRED | | | FOR EACH PARKING FACILITY. | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2018-12-17 |
|
|
Cont ID |
|
| Sent By |
RRossano |
Date |
2018-12-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2018-12-17 |
Time |
|
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2018-11-29 |
|
|
Cont ID |
|
| Sent By |
RRossano |
Date |
2018-11-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2018-11-29 |
Time |
|
Sent To |
B |
|
| Notes |
| 2018-11-29 06:55:48 | PLEASE SEE COMMENTS BELOW AND ATTACHMENT FROM TRACY | | | WARD, SENIOR STORMWATER ENGINEER, ENGINEERING SERVICES, | | | 561-494-1120: | | | | | | SHEET C-1: PLEASE LABEL VERTICAL DATUM & PROVIDE | | | CONVERSION EQUATION TO NGVD '29. | | | SHEET C-2: PLEASE PROVIDE CONVERSION EQUATION TO NGVD | | | '29. | | | SHEET C-3: PLEASE REVISE STORMWATER CALCULATIONS PER | | | ATTACHMENT. (ENVIRONMENTAL RESOURCE PERMIT INFORMATION | | | MANUAL, PT. III - REFERENCES & DESIGN AIDS, SECTION U - | | | DESIGN EXAMPLE FOR EXFILTRATION TRENCH & MARKUP OF | | | SHEET U-6) | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO | | | PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1098 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | MANNY GONZALEZ | | | SENIOR ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2018-10-15 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2018-10-15 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
2018-10-15 |
Time |
|
Sent To |
B |
|
| Notes |
| 2018-10-15 10:57:30 | 1) SHOW 6 INCH DIP LATERAL AND ASSOCIATED ON-SITE FIRE | | | HYDRANT. BOTH ARE IN VINCINITY OF PROPOSED PARKING LOT | | | IMPROVEMENTS. | | | 2) THERE ARE WATER AND SEWER LINES IN THE VICINITY OF | | | THIS PROJECT. PER CHAPTER 556 OF THE FLORIDA STATE | | | STATUTES, YOU MUST CALL 811 FOR UTILITY LOCATES AT | | | LEAST TWO FULL BUSINESS DAYS IN ADVANCE OF ANY | | | CONSTRUCTION OR DEMOLITION WORK. MORE INFORMATION CAN | | | BE FOUND HERE: HTTP://WWW.SUNSHINE811.COM/ | | | 3) COMPLY WITH WPB PARKING DETAILS (ATTACHED TO | | | APPLICATION PACKAGE FOR YOUR USE). | | | | | | THE FOLLOWING COMMENTS ARE FROM TRACY WARD, SENIOR | | | STORMWATER ENGINEER, CITY OF WPB ENGINEERING SERVICES, | | | 561-494-1120 | | | SHEET C-1 | | | 1) IS PARKING LOT ENTRANCE TOO CLOSE TO ROAD RIGHT OF | | | WAY (15 FEET)? | | | SHEET C-2 | | | 1) DRAWINGS PROPOSE 12? HDPE PIPE BETWEEN SECTIONS OF | | | 15? PERFORATED PIPE. PLEASE REVISE. | | | 2) CONSIDER SHORTENING PARKING SPACES TO 16? SINCE | | | CURBING IS ALREADY BEING USED. | | | SHEET C-3 | | | 1) H2 IS DEPTH TO WATER TABLE OR TRENCH, WHICHEVER IS | | | LESS. IT IS MEASURED FROM THE CONTROL ELEVATION (WEIR) | | | OR THE MINIMUM GRATE ELEVATION. SINCE THERE IS NO | | | OUTFALL, THE MINIMUM GRATE ELEVATION IS USED (14.80). | | | TOP OF TRENCH ELEVATION IS SHOWN AS 13.50, AND TRENCH | | | IS 4 FEET DEEP. BOTTOM OF TRENCH IS 13.50 ? 4 = 9.50. | | | H2 = 14.80 ? 9.50 = 5.3. VOLUME TREATED = 1780 C.F. | | | LESS THAN 15.16 C.F. IS OK. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO | | | PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1098 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | MANNY GONZALEZ | | | SENIOR ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-12-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-17 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-06 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2018-12-07 14:51:33 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-12-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-03 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-11-15 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2018-11-16 09:59:52 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-10-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-10-24 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-10-04 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2018-10-05 14:05:01 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-12-14 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-12-14 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-12-14 |
Time |
09:57 |
Sent To |
ENG |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-11-27 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-11-27 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-11-27 |
Time |
14:24 |
Sent To |
ENG |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-10-12 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-10-12 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-10-12 |
Time |
09:36 |
Sent To |
ENG |
|
| Notes |
| 2018-10-12 11:39:00 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | | | 1) SEPARATE LANDSCAPE PERMIT REQUIRED. ZONING WILL | | | APPROVE ONCE LANDSCAPING IS ADDRESSED. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] |
|
|