Plan Review Details - Permit 18100156
Plan Review Stops For Permit 18100156
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-03-28 Cont ID  
Sent By jgomez Date 2019-03-28 Time 16:50 Rev Time 0.00
Received By jgomez Date 2019-03-28 Time 14:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-01-30 Cont ID  
Sent By jgomez Date 2019-01-30 Time 10:51 Rev Time 0.00
Received By jgomez Date 2019-01-29 Time 18:50 Sent To  
Notes
2019-01-30 10:52:11RESIDENTIAL (R3) ADDITION SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE. (NOTE: ALL DRAWINGS NEED TO HAVE THE
 ENGINEER'S SEAL PRIOR TO ISSUANCE OF PERMIT)
  
  
  
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL)
  
 ORIGINAL COMMENT:
 FLAT ROOF NOA 17-0222.09 SUBMITTED; CLEARLY MARK
 SPECIFIC ASSEMBLY TO BE INSTALLED AND PROVIDE SIGNED
 AND SEALED RAS 117 CALCULATIONS FOR PERIMETER AND
 CORNER AREAS AS REQUIRED BY GENERAL LIMITATION #7 ON
 LAST PAGE OF NOA SUBMITTED. NEED RAS 117 CALCULATIONS
 TO MEET THE DESIGN PRESSURES OF EACH ROOF ZONE AS
 REQUIRED BY SEC. R301.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 ENGINEER RAS 117 CALCULATIONS SUBMITTED NEED TO BE
 REVISED:
 A) REVISE THE PARAMETERS CRITERIA:
 (1)THE BUILDING EXPOSURE IS "C" NOT "B". SEE SEC.
 R301.2.1.4 FBC-RESIDENTIAL.
  
 (2)THE RISK CATEGORY IS 2 NOT 1. SEE TABLE 1604.5 FBC.
  
 B)APPROVED ASSEMBLY FROM NOA 17-0222.09 IS NOT
 IDENTIFIED ON THE CALCULATION. SEC. R301.1
 FBC-RESIDENTIAL.
  
 C) FRONT PAGE CALLS FOR "CERTAINTEED MODIFIED BITUMEN
 ROOFING SYSTEM". NOA SUBMITTED IS FOR "TAMKO MODIFIED
 BITUMEN ROOFING SYSTEM" NOT CERTAINTEED. REVISE AS
 REQUIRED TO MATCH NOA SUBMITTED. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 D) FASTENER DENSITIES SPECIFIED FOR ROOF ZONE #1 (FIELD
 ZONE) DON'T CORRESPOND TO FASTENER DENSITIES SHOWN ON
 PRODUCT APPROVAL SUBMITTED.
  
 E) CLEARLY SPECIFY FASTENER TYPE AND SPACING FOR EACH
 ROOF ZONE, INCLUDING NUMBER OF ROWS IN THE CENTER OF
 THE SHEET. SEC. R301.1 FBC-RESIDENTIAL.
  
 2- NEW COMMENTS:
 DETAIL "E" ON SHEET S1 IS INCOMPLETE. NEED TO SPECIFY:
 (1)SIZE AND THICKNESS OF "SPECIAL HANGER".
  
 (2) WELDING SPECIFICATIONS. NOTE: INCLUDE WELDING
 SPECIFICATIONS AT BOTTOM OF COLUMN.
  
 (3) SPECIFICATIONS FOR CONNECTION OF WOOD BEAM TO
 SPECIAL CONNECTOR.
  
  
 3- ONE SET OF PLANS IS MISSING THE ENGINEER'S SEAL ON
 DRAWINGS S1, EX2 AND EX3 AS REQUIRED BY CHAPTER 471
 F.S.
  
  
 ARCHITECTS-ENGINEERS
 FLORIDA STATUTE 553.80(2)(B):
 WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW
  
  
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-11-20 Cont ID  
Sent By jgomez Date 2018-11-20 Time 12:53 Rev Time 0.00
Received By jgomez Date 2018-11-19 Time 17:39 Sent To  
Notes
2018-11-20 12:54:32RESIDENTIAL (R3) ADDITION BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- IMPACT FEES - ENTRY AREA SHOWN ON PLANS WAS A
 SCREENED PORCH. PLANS REQUIRE REVIEW BY THE PBC IMPACT
 FEE OFFICE. CALL (561) 233-5025. UPON APPROVAL, YOU MAY
 CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR
 REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF THE
 RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE
 OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO
 V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN
 AIRE.PDF
  
 2- SHEET A2:
 A) PROPOSED FLOOR PLAN SHOWS A NEW ENTRY AREA.
 ACCORDING TO CITY RECORDS AND PALM BEACH COUNTY
 PROPERTY APPRAISER THIS AREA WAS A SCREENED PORCH. (SEE
 EXISTING FLOOR PLAN SHEET EX2 AND PHOTOGRAPHS SUBMITTED
 WITH THE ELEVATION CERTIFICATE). PROPOSED FLOOR PLAN
 HAS A NOTE BELOW THE ENTRY LABEL STATING THAT THE ENTRY
 IS "NOT INCLUDED IN PROJECT". CLARIFY WHY IS NOT
 INCLUDED IN PROJECT IF THE PLANS ARE SHOWING THAT THE
 PORCH IS BEING ALTERED TO AN ENTRY AREA. NEED TO
 PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS FOR
 THE FRAMING OPENINGS THAT WILL RECEIVE THE NEW WINDOWS
 AND FOR THE INFILL OF THE WEST WALL IN THIS AREA.
 CLEARLY SPECIFY ALL FRAMING MEMBERS AND CONNECTORS.
 SEC. R301.1 FBC-RESIDENTIAL.
 NOTE: COORDINATE LABEL OF ROOMS SHOWN ON THE FLOOR PLAN
 AND DOOR SCHEDULE TO AVOID CONFLICTS.
  
 B) A STAIR LANDING IS REQUIRED IN THE NEW STAIRS IN THE
 NEW REAR PORCH. SEC. R311.3 FBC-RESIDENTIAL AND SEC.
 801.3 FBC-EXISTING BUILDING.
  
 C) CLEARLY IDENTIFY IN FLOOR PLAN ALL ROOMS (SPECIALLY
 ALL THE BEDROOMS) TO VERIFY COMPLIANCE WITH THE EGRESS
 REQUIREMENTS OF SEC. 702.5 FBC-EXISTING BUILDING.
  
 3- PROVIDE SPECIFICATIONS FOR ROOF SHEATHING. PLANS
 DON'T SPECIFY THICKNESS OF ROOF SHEATHING. SEC. R803
 FBC-RESIDENTIAL.
 NOTE; ALSO, COORDINATE ROOF SHEATHING NAILING TYPE AND
 NAILING SPACING. SPECIFICATION ON ROOF LAYOUT ON SHEET
 S1 DON'T MATCH PLYWOOD SHEATHING NAILING SCHEDULE ON
 SAME SHEET. REVISE AS REQUIRED TO MATCH. SEC. 107.2.1
 CITY AMENDMENTS.
  
 4- DIMENSIONS SHOWN ON THE PROPOSED SITE PLAN ON SHEET
 A1 AND EXISTING SITE PLAN ON SHEET EX1 DON'T MATCH
 DIMENSIONS SHOWN IN THE SURVEY. REVISE AS REQUIRED TO
 MATCH. SEC. 107.2.1 CITY AMENDMENTS.
  
 5- CLARIFY WHY SUBMITTING AN ELEVATION CERTIFICATE. IF
 THIS PROPERTY IS NOT LOCATED IN A DESIGNATED FLOOD
 HAZARD AREA. SEC. 107.2.1 CITY AMENDMENTS.
  
 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL)
  
 A) WINDOW MULLIONS AS SHOWN ON PLANS (ENTRY AREA).
 REQUIRED: CLEARLY SPECIFY MULLION SIZE TO BE USED TO
 VERIFY COMPLIANCE WITH THE CALCULATED DESIGN PRESSURES.
  
 B) SLIDING GLASS DOORS AS SHOWN ON PLANS.
  
 C) FLAT ROOF NOA 17-0222.09 SUBMITTED; CLEARLY MARK
 SPECIFIC ASSEMBLY TO BE INSTALLED AND PROVIDE SIGNED
 AND SEALED RAS 117 CALCULATIONS FOR PERIMETER AND
 CORNER AREAS AS REQUIRED BY GENERAL LIMITATION #7 ON
 LAST PAGE OF NOA SUBMITTED. NEED RAS 117 CALCULATIONS
 TO MEET THE DESIGN PRESSURES OF EACH ROOF ZONE AS
 REQUIRED BY SEC. R301.1 FBC-RESIDENTIAL.
  
 D) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS
 AND DETAILS. NOTE: PROVIDE ONLY THE FLORIDA PRODUCT
 APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED
 CONNECTOR OR DESIGN PROFESSIONAL TO LIST THE FLORIDA
 PRODUCT APPROVAL NUMBER NEXT TO EACH SPECIFIED
 CONNECTOR
  
 7- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS
 FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2019-03-26 Cont ID  
Sent By jpearson Date 2019-03-26 Time 10:05 Rev Time 0.00
Received By jpearson Date 2019-03-26 Time 10:05 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-02-03 Cont ID  
Sent By jpearson Date 2019-02-03 Time 11:32 Rev Time 0.00
Received By jpearson Date 2019-02-03 Time 11:32 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-10-29 Cont ID  
Sent By jpearson Date 2018-10-29 Time 11:01 Rev Time 0.00
Received By jpearson Date 2018-10-29 Time 11:01 Sent To  
Notes
2018-10-29 11:00:59CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND
 SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. IF
 THERE IS NO ELECTRICAL WORK IN THIS PROJECT, STATE THAT
 ON PLAN. WPB FBC 107.1, 107.2.1, 107.3.5; FS 471, 481
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2019-04-17 Cont ID  
Sent By jgomez Date 2019-04-17 Time 09:09 Rev Time 0.00
Received By jgomez Date 2019-04-15 Time 14:50 Sent To I
Notes
2019-04-16 14:50:32IMPACT FEES ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-03-28 Cont ID  
Sent By jgomez Date 2019-03-28 Time 16:50 Rev Time 0.00
Received By jgomez Date 2019-03-22 Time 15:45 Sent To I
Notes
2019-03-25 15:45:59RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2019-02-03 Time   Rev Time 0.00
Received By lmarchan Date 2019-01-15 Time 16:04 Sent To  
Notes
2019-01-16 16:04:26R29

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-11-20 Cont ID  
Sent By jgomez Date 2018-11-20 Time 12:56 Rev Time 0.00
Received By jgomez Date 2018-10-03 Time 10:27 Sent To I
Notes
2018-10-11 16:23:32R11
2018-10-05 10:27:26LIBRARY

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2019-04-17 Cont ID  
Sent By jgomez Date 2019-04-17 Time 09:08 Rev Time 0.00
Received By jgomez Date 2019-04-17 Time 08:51 Sent To  
Notes
2019-04-17 09:08:57NO FEES DUE. MU-2019-011125.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2019-03-28 Cont ID  
Sent By jgomez Date 2019-03-28 Time 16:27 Rev Time 0.00
Received By jgomez Date 2019-03-28 Time 16:27 Sent To  
Notes
2019-03-28 16:27:411- IMPACT FEES - ENTRY AREA SHOWN ON PLANS WAS A
 SCREENED PORCH. PLANS REQUIRE REVIEW BY THE PBC IMPACT
 FEE OFFICE. CALL (561) 233-5025. UPON APPROVAL, YOU MAY
 CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR
 REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF THE
 RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE
 OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO
 V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN
 AIRE.PDF

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2019-01-30 Cont ID  
Sent By jgomez Date 2019-01-30 Time 09:16 Rev Time 0.00
Received By jgomez Date 2019-01-30 Time 09:16 Sent To  
Notes
2019-01-30 09:17:261- IMPACT FEES - ENTRY AREA SHOWN ON PLANS WAS A
 SCREENED PORCH. PLANS REQUIRE REVIEW BY THE PBC IMPACT
 FEE OFFICE. CALL (561) 233-5025. UPON APPROVAL, YOU MAY
 CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR
 REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF THE
 RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE
 OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO
 V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN
 AIRE.PDF

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-11-20 Cont ID  
Sent By jgomez Date 2018-11-20 Time 11:07 Rev Time 0.00
Received By jgomez Date 2018-11-20 Time 11:07 Sent To  
Notes
2018-11-20 11:08:241- IMPACT FEES - ENTRY AREA SHOWN ON PLANS WAS A
 SCREENED PORCH. PLANS REQUIRE REVIEW BY THE PBC IMPACT
 FEE OFFICE. CALL (561) 233-5025. UPON APPROVAL, YOU MAY
 CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR
 REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF THE
 RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE
 OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO
 V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN
 AIRE.PDF

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2019-03-28 Cont ID  
Sent By jgomez Date 2019-03-28 Time 16:39 Rev Time 0.00
Received By jgomez Date 2019-03-28 Time 16:39 Sent To  
Notes
2019-03-28 16:40:341- TAMKO FLAT ROOF NOA 17-0222.09 WITH FLORIDA PRODUCT
 APPROVAL FL735-R12 SUBMITTED.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2019-01-30 Cont ID  
Sent By jgomez Date 2019-01-30 Time 10:52 Rev Time 0.00
Received By jgomez Date 2019-01-30 Time 10:52 Sent To  
Notes
2019-01-30 10:53:101- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL)
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
  
  
  
  
 ORIGINAL COMMENT:
 FLAT ROOF NOA 17-0222.09 SUBMITTED; CLEARLY MARK
 SPECIFIC ASSEMBLY TO BE INSTALLED AND PROVIDE SIGNED
 AND SEALED RAS 117 CALCULATIONS FOR PERIMETER AND
 CORNER AREAS AS REQUIRED BY GENERAL LIMITATION #7 ON
 LAST PAGE OF NOA SUBMITTED. NEED RAS 117 CALCULATIONS
 TO MEET THE DESIGN PRESSURES OF EACH ROOF ZONE AS
 REQUIRED BY SEC. R301.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 ENGINEER RAS 117 CALCULATIONS SUBMITTED NEED TO BE
 REVISED:
 A) REVISE THE PARAMETERS CRITERIA:
 (1)THE BUILDING EXPOSURE IS "C" NOT "B". SEE SEC.
 R301.2.1.4 FBC-RESIDENTIAL.
  
 (2)THE RISK CATEGORY IS 2 NOT 1. SEE TABLE 1604.5 FBC.
  
 B)APPROVED ASSEMBLY FROM NOA 17-0222.09 IS NOT
 IDENTIFIED ON THE CALCULATION. SEC. R301.1
 FBC-RESIDENTIAL.
  
 C) FRONT PAGE CALLS FOR "CERTAINTEED MODIFIED BITUMEN
 ROOFING SYSTEM". NOA SUBMITTED IS FOR "TAMKO MODIFIED
 BITUMEN ROOFING SYSTEM" NOT CERTAINTEED. REVISE AS
 REQUIRED TO MATCH NOA SUBMITTED. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 D) FASTENER DENSITIES SPECIFIED FOR ROOF ZONE #1 (FIELD
 ZONE) DON'T CORRESPOND TO FASTENER DENSITIES SHOWN ON
 PRODUCT APPROVAL SUBMITTED.
  
 E) CLEARLY SPECIFY FASTENER TYPE AND SPACING FOR EACH
 ROOF ZONE, INCLUDING NUMBER OF ROWS IN THE CENTER OF
 THE SHEET. SEC. R301.1 FBC-RESIDENTIAL.
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2018-11-20 Cont ID  
Sent By jgomez Date 2018-11-20 Time 12:55 Rev Time 0.00
Received By jgomez Date 2018-11-20 Time 12:55 Sent To  
Notes
2018-11-20 12:55:561- FLAT ROOF NOA 17-0222.09 SUBMITTED; CLEARLY MARK
 SPECIFIC ASSEMBLY TO BE INSTALLED AND PROVIDE SIGNED
 AND SEALED RAS 117 CALCULATIONS FOR PERIMETER AND
 CORNER AREAS AS REQUIRED BY GENERAL LIMITATION #7 ON
 LAST PAGE OF NOA SUBMITTED. NEED RAS 117 CALCULATIONS
 TO MEET THE DESIGN PRESSURES OF EACH ROOF ZONE AS
 REQUIRED BY SEC. R301.1 FBC-RESIDENTIAL.
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2019-01-23 Cont ID  
Sent By awooten Date 2019-01-23 Time   Rev Time 0.00
Received By awooten Date 2019-01-23 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2018-10-26 Cont ID  
Sent By awooten Date 2018-10-26 Time   Rev Time  
Received By awooten Date 2018-10-26 Time   Sent To  
Notes
***NONE***