Plan Review Details - Permit 18100122
| Plan Review Stops For Permit 18100122 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-10-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-10-18 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-10-18 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-10-05 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-10-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-10-05 |
Time |
11:38 |
Sent To |
E |
|
| Notes |
| 2018-10-05 11:43:25 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION | | | | | | | | | 1) THE INDICATED CODE REFERENCE, 7.2.1.5 DOES NOT | | | APPEAR TO BE ACCURATE. | | | | | | PER NFPA 101, CHAPTER 7 MEANS OF EGRESS | | | | | | 7.2.1.5.6 ELECTRICALLY CONTROLLED EGRESS DOOR | | | ASSEMBLIES. DOOR | | | ASSEMBLIES IN THE MEANS OF EGRESS SHALL BE PERMITTED TO | | | BE | | | ELECTRICALLY LOCKED IF EQUIPPED WITH APPROVED, LISTED | | | HARDWARE, | | | PROVIDED THAT ALL OF THE FOLLOWING CONDITIONS ARE MET: | | | (1) THE HARDWARE FOR OCCUPANT RELEASE OF THE LOCK IS | | | AFFIXED TO | | | THE DOOR LEAF. | | | (2) THE HARDWARE HAS AN OBVIOUS METHOD OF OPERATION | | | THAT IS | | | READILY OPERATED IN THE DIRECTION OF EGRESS. | | | (3) THE HARDWARE IS CAPABLE OF BEING OPERATED WITH ONE | | | HAND IN | | | THE DIRECTION OF EGRESS. | | | (4) OPERATION OF THE HARDWARE INTERRUPTS THE POWER | | | SUPPLY | | | DIRECTLY TO THE ELECTRIC LOCK AND UNLOCKS THE DOOR | | | ASSEMBLY IN | | | THE DIRECTION OF EGRESS. | | | (5) *LOSS OF POWER TO THE LISTED RELEASING HARDWARE | | | AUTOMATICALLY UNLOCKS THE DOOR ASSEMBLY IN THE | | | DIRECTION OF | | | EGRESS. | | | (6) HARDWARE FOR NEW INSTALLATIONS IS LISTED IN | | | ACCORDANCE WITH | | | ANSI/UL 294, STANDARD FOR ACCESS CONTROL SYSTEM UNITS. | | | | | | | | | PLEASE ENSURE COMPLIANCE | | | | | | | | | | | | 2) UPDATE YOUR CODE REFERENCES ON FUURE SUBMITTALS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-10-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-10-18 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-10-02 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2018-10-03 15:37:22 | ROUTED TO FIRE INBOX |
|
|
|