| Plan Review Stops For Permit 18100064 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-12-21 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2018-12-21 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-11-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-11-13 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-11-13 |
Time |
07:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-12-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-12-19 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-12-19 |
Time |
15:52 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-10-18 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-18 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-18 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2018-10-18 15:21:58 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. SHEET E9-20, NOTE 1 CALLS FOR A 60KW DIESEL GENSET | | | WHICH CORRESPONDS WITH SPEC SHEET PROVIDED FOR | | | GENERATOR. SHEET E9-30 AND E9-40 CALL FOR A 50KW | | | GENSET. CORRECT DISCREPANCY. WPB FBC 107.2.1 | | | 2. THE ADDRESS ON PLANS NEEDS TO BE CLARIFIED. THIS | | | PERMIT APPLICATION IS FOR 111 EXECUTIVE CENTER DR., | | | WHILE PERMIT APPLICATION 18100068 IS FOR 101 EXECUTIVE | | | CENTER DR.. EITHER PROVIDE BOTH ADDRESSES ON PLAN SET, | | | OR SUBMIT SEPARATE PLAN FOR EACH ADDRESS. WPB FBC | | | 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-12-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-12-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-12-10 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2018-12-10 15:30:09 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) THE INSTALLATION OF THE GENERATOR SHALL COMPLY WITH | | | THE REQUIRMENTS OF NFPA 37. | | | | | | PER NFPA 1, CHAPTER 11, BUILDING SERVICES | | | | | | 11.7 STATIONARY GENERATORS AND STANDBY POWER SYSTEMS | | | 11.7.1 11.7.1 STATIONARY COMBUSTION ENGINES AND GAS | | | TURBINES | | | INSTALLATION. STATIONARY GENERATOR SETS SHALL BE | | | INSTALLED IN | | | ACCORDANCE WITH NFPA 37, STANDARD FOR THE INSTALLATION | | | AND USE | | | OF STATIONARY COMBUSTION ENGINES AND GAS TURBINES, AND | | | NFPA 70. | | | | | | | | | | | | 2) ANY PROPOSED TIE IN TO THE FIRE ALARM AND/OR FIRE | | | SPRINKLER SYSTEM SHALL BE DONE UNDER SEPARATE SHOP | | | DRAWINGS UNDER APPLICABLE NFPA CODES. | | | | | | | | | 3) TIE IN TO ANY LIFE SAFETY SYSTEMS OR AS PER | | | APPLICABLE LAW SHALL BE UNDER NFPA 110 | | | | | | 11.7.3 EMERGENCY AND LEGALLY REQUIRED STANDBY POWER | | | SYSTEMS. | | | 11.7.3.1 GENERAL. NEW STATIONARY GENERATORS FOR | | | EMERGENCY USE | | | OR FOR LEGALLY REQUIRED STANDBY POWER REQUIRED BY THIS | | | CODE, THE | | | BUILDING CODE, OR OTHER CODES AND STANDARDS SHALL BE | | | INSTALLED IN | | | ACCORDANCE WITH NFPA 110, STANDARD FOR EMERGENCY AND | | | STANDBY | | | POWER SYSTEMS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-10-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-10-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-10-10 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2018-10-10 14:12:02 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) THE INSTALLATION OF THE GENERATOR SHALL COMPLY WITH | | | THE REQUIRMENTS OF NFPA 37. | | | | | | PER NFPA 1, CHAPTER 11, BUILDING SERVICES | | | | | | 11.7 STATIONARY GENERATORS AND STANDBY POWER SYSTEMS | | | 11.7.1 11.7.1 STATIONARY COMBUSTION ENGINES AND GAS | | | TURBINES | | | INSTALLATION. STATIONARY GENERATOR SETS SHALL BE | | | INSTALLED IN | | | ACCORDANCE WITH NFPA 37, STANDARD FOR THE INSTALLATION | | | AND USE | | | OF STATIONARY COMBUSTION ENGINES AND GAS TURBINES, AND | | | NFPA 70. | | | | | | | | | | | | 2) ANY PROPOSED TIE IN TO THE FIRE ALARM AND/OR FIRE | | | SPRINKLER SYSTEM SHALL BE DONE UNDER SEPARATE SHOP | | | DRAWINGS UNDER APPLICABLE NFPA CODES. | | | | | | | | | 3) TIE IN TO ANY LIFE SAFETY SYSTEMS OR AS PER | | | APPLICABLE LAW SHALL BE UNDER NFPA 110 | | | | | | 11.7.3 EMERGENCY AND LEGALLY REQUIRED STANDBY POWER | | | SYSTEMS. | | | 11.7.3.1 GENERAL. NEW STATIONARY GENERATORS FOR | | | EMERGENCY USE | | | OR FOR LEGALLY REQUIRED STANDBY POWER REQUIRED BY THIS | | | CODE, THE | | | BUILDING CODE, OR OTHER CODES AND STANDARDS SHALL BE | | | INSTALLED IN | | | ACCORDANCE WITH NFPA 110, STANDARD FOR EMERGENCY AND | | | STANDBY | | | POWER SYSTEMS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2018-12-21 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2018-12-05 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2018-12-07 10:32:23 | B12 | | | **TRAVELLING TOGETHER 18100064 & 18100068** |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-11-13 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-11-13 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-10-02 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2018-10-04 10:33:36 | B12 | | | **TRAVELLING TOGETHER 18100064 & 18100068** |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
2019-02-01 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
2019-02-01 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
2019-02-01 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2019-02-01 14:49:39 | SEPARATE LANDSCAPE PERMITS SUBMITTED AND | | | APPROVED.19011205 AND 19011207 |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2019-01-15 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
2019-01-15 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
2019-01-15 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2019-01-15 14:38:46 | PROVIDE SPECIES NAME FOR HEDGE PLANTS, AND SHOW FINAL | | | LOCATION OF 2 RELOCATED PALMS. | | | SUBMIT A TREE ALTERATION PERMIT FOR RELOCATION OF | | | PALMS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-02-01 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-02-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-02-01 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2018-12-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2018-12-21 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-12-21 10:48:59 | *************************ZONING REVIEW | | | FAILED***************************** | | | | | | PROVIDE A TREE ALTERATION APPLICATION FOR THE TREES | | | BEING RELOCATED ON SHEET C9-20, AND A SEPARATE | | | LANDSCAPE PERMIT FOR THE HEDGE SCREENING. PLEASE | | | CONTACT RAY CARANCI WITH ANY QUESTIONS (561-822-1462). | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-10-17 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2018-10-17 |
Time |
|
Rev Time |
|
| Received By |
awooten |
Date |
2018-10-17 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-10-17 14:32:09 | ****************************************ZONING REVIEW | | | FAILED******************************************** | | | | | | PROVIDE THE SETBACKS FOR THE GENERATOR (MINIMUM OF 4 | | | FEET INTO THE REQUIRED SETBACK). | | | | | | ARE ANY TREES BEING MOVED/RELOCATED? | | | | | | WHAT SCREENING IS BEING PROVIDED? | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|