Plan Review Details - Permit 18091286
Plan Review Stops For Permit 18091286
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-12-03 Cont ID  
Sent By cthroop Date 2018-12-03 Time 14:35 Rev Time 0.00
Received By cthroop Date 2018-12-03 Time 14:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-10-22 Cont ID  
Sent By cthroop Date 2018-10-22 Time 11:55 Rev Time 0.00
Received By cthroop Date 2018-10-22 Time 10:35 Sent To ENG
Notes
2018-10-22 11:57:37BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE SITE DRAINAGE PLAN.
  
 FBC R401.3 SITE DRAINAGE
 PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING
 COMPLIANCE WITH FBC R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
 LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES WITHIN THE FIRST 10 FEET.
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN 10
 FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE
 DRAINAGE AWAY FROM THE STRUCTURE.
 IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING
 FOUNDATION SHALL BE SLOPED A MINIMUM OF
 2 PERCENT AWAY FROM THE BUILDING.
  
 FBC R 401.3 (DRAINAGE)
 FBC 107.2.5 (SITE PLAN)
 FBC 110.9 (IMPACT OF CONSTRUCTION)
  
 2. PROPOSEED WALL ENCROACHES INTO A PUBLIC UTILITY
 EASEMENT. AN ENGINEERING REVIEW IS REQUIRED.
  
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2018-11-28 Cont ID  
Sent By RRossano Date 2018-11-28 Time   Rev Time 0.00
Received By rrossano Date 2018-11-28 Time   Sent To B
Notes
2018-11-28 09:43:15PASSED WITH PROVISOS:
  
 1) THERE ARE WATER AND SEWER LINES IN THE VICINITY OF
 THIS PROJECT. PER CHAPTER 556 OF THE FLORIDA STATE
 STATUTES, YOU MUST CALL 811 FOR UTILITY LOCATES AT
 LEAST TWO FULL BUSINESS DAYS IN ADVANCE OF ANY
 CONSTRUCTION OR DEMOLITION WORK. MORE INFORMATION CAN
 BE FOUND HERE: HTTP://WWW.SUNSHINE811.COM/
  
 2) CONTACT PUBLIC UTILITIES CUSTOMER SERVICE AT
 561-822-1300 TO REQUEST A NEW WATER METER BOX (EXISTING
 WATER METER BOX CURRENTLY LOCATED IN SIDEWALK AT
 PROPOSED DRIVEWAY LOCATION).
  
 FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR
 CONCERNS, THANKS.
  
 RICK ROSSANO
 PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1098
 FAX: (561) 494-1116
 MOBILE: (561) 246-9525
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 MANNY GONZALEZ
 SENIOR ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2018-10-26 Cont ID  
Sent By rrossano Date 2018-10-26 Time   Rev Time 0.00
Received By rrossano Date 2018-10-26 Time   Sent To I
Notes
2018-10-26 11:33:54CLEARLY SHOW LOCATION OF WATER METER ON SOUTH SIDE OF
 PROPERTY. PROPOSED WALL MUST NOT RESTRICT ACCESS TO
 WATER METER BY CITY OF WPB UTILITY PERSONNEL.
2018-10-26 10:04:48OVER PUE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-12-03 Cont ID  
Sent By cthroop Date 2018-12-03 Time 14:35 Rev Time 0.00
Received By cthroop Date 2018-11-14 Time 14:53 Sent To  
Notes
2018-11-15 14:53:37RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-10-22 Cont ID  
Sent By cthroop Date 2018-10-22 Time 11:57 Rev Time 0.00
Received By cthroop Date 2018-09-27 Time 11:26 Sent To Z
Notes
2018-10-17 12:54:5310/17 TO JG DESK
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status P Date 2018-12-03 Cont ID  
Sent By cthroop Date 2018-12-03 Time 14:35 Rev Time 0.00
Received By cthroop Date 2018-12-03 Time 14:26 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2018-10-26 Cont ID  
Sent By cthroop Date 2018-10-26 Time 10:52 Rev Time 0.00
Received By cthroop Date 2018-10-26 Time 10:52 Sent To  
Notes
2018-10-26 10:57:43BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. BASED ON THE SUBMITTED SURVEY, THIS LOT AND PROPOSED
 IMPROVEMENTS ARE LOCATED IN AN AE FLOOD ZONE WITH A
 BASE FLOOD ELEVATION (BFE) OF 7.0 FEET NAVD.
 2. AS OF OCTOBER 5, 2017, THE FEDERAL EMERGENCY
 MANAGEMENT AGENCY (FEMA) ESTABLISHED A NEW FLOOD
 INSURANCE RATE MAP (FIRM) UTILIZING THE RECENTLY
 COMPLETED FLOOD HAZARD DETERMINATION (FHD) FOR THE CITY
 OF WEST PALM BEACH, FL.
 3. ALL NEW BASE FLOOD ELEVATIONS (BFE) SHALL BE BASED
 ON NAVD88 DATUM. ON AUGUST 23, 2017, THE CITY OF WEST
 PALM BEACH, BY ORDINANCE, ESTABLISHED A TWO FOOT
 FREEBOARD ABOVE THE (BFE).
 4. YOU MAY SUBMIT A NEW SURVEY SHOWING ALL EXISTING AND
 PROPOSED ELEVATIONS BASED ON NAVD88 DATUM PLUS TWO FEET
 OF FREEBOARD OR THE ENGINEER OF RECORD (EOR) MAY ADD A
 STATEMENT TO THE STRUCTURAL PLAN THAT THE DESIGN FLOOD
 ELEVATION (DFE) WILL BE 9.00 FEET NAVD88 BASED ON THE
 (BFE) OF 7.00 FEET FOR FLOOD ZONE AE PLUS TWO FEET OF
 FREEBOARD.
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2018-11-27 Cont ID  
Sent By mcruz Date 2018-11-27 Time 14:10 Rev Time 0.00
Received By mcruz Date 2018-11-27 Time 14:08 Sent To ENG
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2018-10-02 Cont ID  
Sent By cthroop Date 2018-10-22 Time 11:57 Rev Time 0.00
Received By mcruz Date 2018-10-02 Time 16:35 Sent To B
Notes
2018-10-02 16:46:10ZONING REVIEW FAILED, DUE TO THE FOLLOWING:
  
 1) PURSUANT TO THE ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDR), SECTION 305(E), VISIBILITY AT
 INTERSECTIONS. AT ANY ROAD INTERSECTIONS, VISIBILITY
 SHALL NOT BE OBSCURED BY THE CONSTRUCTION, PLACEMENT,
 OR MAINTENANCE OF A STRUCTURE WALL, SIGN, FENCE, BERM,
 PLANT MATERIAL, SHRUBS, OR ANY SIMILAR ITEM BETWEEN 18
 INCHES OR EIGHT FEET IN HEIGHT WITHIN A TRIANGLE
 BEGINNING AT THE POINT WHERE PROPERTY LINES MEET AT THE
 CORNER, THEN 20 FEET ALONG THE FRONT PROPERTY LINE,
 THENCE DIAGONALLY TO A POINT ALONG THE SIDE PROPERTY
 LINE 20 FEET FROM THE POINT OF BEGINNING, AND THENCE TO
 THE POINT OF BEGINNING. IN THE EVENT THE CORNER OF AN
 INTERSECTION IS ROUNDED, THE MEASUREMENT SHALL BEGIN AT
 THE POINT THE PROPERTY LINES WOULD MEET WITHOUT
 ROUNDING. (SEE FIGURE X-1, ENCLOSED).
  
 NOTE: FENCES, WALLS, OR GATES SHALL NOT EXCEED 4 FEET
 IN HEIGHT WITHIN THE REQUIRED FRONT SETBACK OF 25 FEET.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ
 ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: 561-822-1442
 E-MAIL: [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved