Plan Review Details - Permit 18091199
Plan Review Stops For Permit 18091199
Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status N Date 2019-03-05 Cont ID  
Sent By shill Date 2019-03-05 Time 07:40 Rev Time 0.00
Received By shill Date 2019-03-05 Time 07:40 Sent To  
Notes
2019-03-05 07:40:32NOT REQUIRED PER S.WELTER
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-02-05 Cont ID  
Sent By dbattles Date 2019-02-05 Time 11:11 Rev Time 0.00
Received By dbattles Date 2019-02-05 Time 11:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-12-27 Cont ID  
Sent By dbattles Date 2018-12-27 Time 13:44 Rev Time 0.00
Received By dbattles Date 2018-12-26 Time 15:30 Sent To  
Notes
2018-12-27 13:44:37****CORRECTIONS****
 W.P.B. PERMIT: 18091199
 REVIEWED: DECEMBER 27, 2018
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC ENERGY = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. ART IN PUBLIC PLACES
 THE CITY OF WEST PALM BEACH ART IN PUBLIC PLACES
 ORDINANCE REQUIREMENT THAT APPLIES TO ANY REMODEL OR
 NEW CONSTRUCTION PROJECT FOR WHICH THE PERMIT
 APPLICATION WAS SUBMITTED AFTER 6/29/14, AND THE TOTAL
 PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN
 $750,000 WILL NEED TO COMPLY WITH THIS ORDINANCE.
 PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND
 CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V,
 ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION
 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL
 PROJECT CONSTRUCTION COST.
 PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE
 V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND
 NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO
 THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE
 PROJECTS.
 SEC. 78-129. - PUBLIC ART ASSESSMENT FOR PRIVATE
 DEVELOPMENT.
 (A) APPLICABILITY. THE PROVISIONS OF THIS ARTICLE AND
 THE PUBLIC ART ASSESSMENT SECTION SHALL APPLY TO ALL
 PRIVATE DEVELOPMENT PROJECTS, INCLUDING NEW
 CONSTRUCTION, OR THE RENOVATION OR IMPROVEMENT OF AN
 EXISTING BUILDING, WHERE TOTAL CONSTRUCTION COSTS ARE
 EQUAL TO OR GREATER THAN $750,000.00. ALL BUILDINGS
 WITHIN NEW PLANNED DEVELOPMENTS SHALL BE ASSESSED
 CUMULATIVELY TOWARDS THIS ART IN PUBLIC PLACES
 REQUIREMENT, EVEN IF THE BUILDINGS ARE PERMITTED
 SEPARATELY OR DEVELOPED IN PHASES. THE PROVISIONS OF
 THIS SECTION APPLY TO NEW DEVELOPMENT OR NEW
 CONSTRUCTION WITHIN EXISTING PLANNED DEVELOPMENTS.
 FOR CONTACT INFORMATION PLEASE CONTACT:
 MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR
 822-1515 E-MAIL: [email protected]
  
 2. [FBC EXISTING 501]STATE THE LEVEL OF ALTERATION FOR
 WORK BEING PERFORMED.
  
 3. [FBC 804.2]CLASSIFICATION. INTERIOR FLOOR FINISH AND
 FLOOR COVERING MATERIALS REQUIRED BY SECTION 804.4.2 TO
 BE OF CLASS I OR II MATERIALS SHALL BE CLASSIFIED IN
 ACCORDANCE WITH NFPA 253. THE CLASSIFICATION REFERRED
 TO HEREIN CORRESPONDS TO THE CLASSIFICATIONS DETERMINED
 BY NFPA 253 AS FOLLOWS: CLASS I, 0.45 WATTS/CM2 OR
 GREATER; CLASS II, 0.22 WATTS/CM2 OR GREATER.
 A) STATE FLOORING FINISH CLASSIFICATION FOR NEW WORK ON
 SHEET T.03 SECTION 10.
 B) WHAT IS THE TOTAL AREA OF FLOOR WHERE WORK IS
 OCCURING AND WHAT IS THE AFFECTED AREA?
 C) WHAT IS THE EXISTING OCCUPANT LOAD OF THE WORK AREA?
  
 4. [FBC 107.5.3]SHEET ID2.01 SHOWS DETAIL CUT 11/ID4.22
 IN BAR AREA. UPDATE THE PAGE NUMBER BECAUSE IT ISN'T IN
 THE SET, OR REMOVE IF NOT IN USE. ALSO, SAME COMMENT
 FOR SHEET ID2.02 DETAIL CUT 13/ID4.22 AT SERVER 3 AND
 OPEN ENTRY.
 SHEET ID0.01 ALSO SHOWS DETAIL CALL OUTS TO SHEET
 ID4.22. IS THIS SHEET MISSING, OR ARE THE DETAILS ON
 ANOTHER SHEET. PLEASE UPDATE ACCORDINGLY.
  
 5. [FBC 107.5.3]ENLARGED PLANS SHOW DOOR TYPE CALL
 OUTS, BUT I CAN'T FIND DOOR SCHEDULE. PLEASE PROVIDE
 DOOR SCHEDULE WITH DOOR SIZES, TYPE AND IF CLOSERS ARE
 PROVIDED.
 ALSO, ADD DOOR CALL OUT TO THE DOOR AT BISTRO BAR.
  
 6. [FBC 1210.2.2]WALLS AND PARTITIONS. WALLS AND
 PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE SINKS,
 URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD,
 NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS THAN 4
 FEET (1219 MM) ABOVE THE FLOOR, AND EXCEPT FOR
 STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS
 SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY
 MOISTURE.
 PLEASE VERIFY TILE FINISH WALL HEIGHT TO COMPLY WITH
 1210.2.2.
  
 7. [FBC 410.4]PLATFORM CONSTRUCTION. PERMANENT
 PLATFORMS SHALL BE CONSTRUCTED OF MATERIALS AS REQUIRED
 FOR THE TYPE OF CONSTRUCTION OF THE BUILDING IN WHICH
 THE PERMANENT PLATFORM IS LOCATED. PERMANENT PLATFORMS
 ARE PERMITTED TO BE CONSTRUCTED OF
 FIRE-RETARDANT-TREATED WOOD FOR TYPES I, II AND IV
 CONSTRUCTION WHERE THE PLATFORMS ARE NOT MORE THAN 30
 INCHES (762 MM) ABOVE THE MAIN FLOOR, AND NOT MORE THAN
 ONE-THIRD OF THE ROOM FLOOR AREA AND NOT MORE THAN
 3,000 SQUARE FEET (279 M2) IN AREA.
 PLEASE ADD NOTE TO SHEET ID4.02 DETAIL 9 THAT THE WOOD
 USED TO BUILD PLATFORM IS TO BE CONSTRUCTED OF
 FIRE-RETARDANT-TREATED WOOD.
  
 8. [FBC A505.10.1]TOP AND BOTTOM EXTENSION AT
 RAMPS.RAMP HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE
 THE LANDING FOR 12 INCHES (305 MM) MINIMUM BEYOND THE
 TOP AND BOTTOM OF RAMP RUNS. EXTENSIONS SHALL RETURN TO
 A WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE
 CONTINUOUS TO THE HANDRAIL OF AN ADJACENT RAMP RUN.
 PLEASE REVIEW RAMP TO PLATFORM 117 FOR COMPLIANCE WITH
 505.10.1 IN ACCESSIBILITY CODE.
  
 9. [FBC A226.1]THE ACCESSIBILITY CODE REQUIRES 0.05 %
 OF ALL SEATING TO BE ACCESSIBLE.
 WHERE DINING SURFACES ARE PROVIDED FOR THE CONSUMPTION
 OF FOOD OR DRINK, AT LEAST 0.05 PERCENT OF THE SEATING
 SPACES AND STANDING SPACES AT THE DINING SURFACES SHALL
 COMPLY WITH 902.
 SHOW HOW BISTRO BAR WILL COMPLY WITH 226.1 AND 902.
  
 10. [FBC 1016.2]EGRESS THROUGH INTERVENING SPACES.
 EGRESS THROUGH
 INTERVENING SPACES SHALL COMPLY WITH THIS SECTION.
 WHEN EXITING MULTI PURPOSE ROOM THROUGH EXIT 116 OR
 ENTRY 115, DO THEY LEAD TO THE OUTSIDE?
 IF THEY GO THROUGH INTERVENING SPACES INCLUDE THE
 TRAVEL DISTANCE ON LIFE SAFETY AND REVIEW FOR
 COMPLIANCE WITH 1016.2.
  
 NOTE:
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-12-12 Cont ID  
Sent By jleahy Date 2018-12-12 Time 17:43 Rev Time 0.00
Received By jleahy Date 2018-12-12 Time 14:44 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-11-26 Cont ID  
Sent By scaldero Date 2018-11-26 Time 10:53 Rev Time 0.00
Received By scaldero Date 2018-11-26 Time 10:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-03-02 Cont ID  
Sent By shill Date 2019-03-02 Time 11:17 Rev Time 0.00
Received By shill Date 2019-03-01 Time 11:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-02-19 Cont ID  
Sent By gjohnson Date 2019-02-19 Time 12:42 Rev Time 0.00
Received By gjohnson Date 2019-01-30 Time 12:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-01-09 Cont ID  
Sent By gjohnson Date 2019-01-09 Time 17:06 Rev Time 0.00
Received By gjohnson Date 2018-11-15 Time 10:30 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2018-12-27 Cont ID  
Sent By dbattles Date 2018-12-27 Time 13:47 Rev Time 0.00
Received By dbattles Date 2018-12-27 Time 08:09 Sent To  
Notes
2018-12-27 13:49:23NO CHANGE OF OCCUPANCY IN ALTERATION.
 NO ADDED SQ. FT. AND NO ADDED OCCUPANTS.
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2018-12-20 Cont ID  
Sent By ccole Date 2018-12-20 Time 15:20 Rev Time 0.00
Received By ccole Date 2018-12-20 Time 15:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-02-19 Cont ID  
Sent By gjohnson Date 2019-02-19 Time 12:41 Rev Time 0.00
Received By gjohnson Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-01-09 Cont ID  
Sent By gjohnson Date 2019-01-09 Time 15:31 Rev Time 0.00
Received By gjohnson Date 2019-01-09 Time 15:31 Sent To  
Notes
2019-01-09 17:06:011ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. PLEASE PROVIDE PLUMBING FIXTURE COUNT BREAKDOWN BY
 RECONFIGURING THE WOMENS BATHROOM ARE THERE ANY OTHER
 BATHROOMS IN THIS OCCUPANCY WEN I DID THE CALCULATIONS
 USEING THE OCCUPANT LOAD ON SHT. T0.2 I CAME UP WITH 5
 MEN'S AND 7 WOMEN'S TOILETS PER FBC PL TABLE 403.1
 PLEASE CLARIFY HOW YOU ARE COMPLYING WITH THE REQUIRED
 FIXTURE COUNT.
 2. PLEASE INDICATE ON THE PLAN WHAT LEVEL OF ALTERATION
 THIS IS. PER FBC EXISTING CH 5
 3. PROVIDE ISOMETRIC DRAWINGS FOR THE NEW WORK AT THE
 SERVING STATIONS AND BISTRO BAR INCLUDING WATER AND
 SANITARY. PER WPB AMEND TO FBC 107.3.5.1.3(13)
 4. SHT. P2.01 DETAIL #3 SHOWS A TEMPERATURE OF 140 ON
 THE BRANCH TO THE DOUBLE LAVATORY IT SHOULD BE ONLY 110
 PROVIDE THROUGH A TEMPERATURE LIMITING DEVICE COMPLING
 WITH ASSE 1070. PER FBC PL 416.5
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2019-03-02 Cont ID  
Sent By shill Date 2019-03-02 Time 11:17 Rev Time 0.00
Received By shill Date 2019-03-02 Time 11:17 Sent To  
Notes
2019-03-01 12:41:283/1/19 HARD COPIES ROUTED TO SHILL

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2019-02-05 Cont ID  
Sent By dbattles Date 2019-02-05 Time 11:08 Rev Time 0.00
Received By dbattles Date 2019-02-05 Time 11:07 Sent To  
Notes
2019-02-05 11:11:51UPON APPROVAL OF PLUMBING CONTACT THE PERMIT LIBRARIANS
 ABOUT HOW TO SATISFY THE SIGNATURE REQUIREMENT.
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2018-12-26 Cont ID  
Sent By dbattles Date 2018-12-26 Time 16:12 Rev Time 0.00
Received By dbattles Date 2018-12-26 Time 16:06 Sent To  
Notes
2018-12-26 16:16:22THE SHEETS IN THE DRAWING FOLDER ARE NOT ELECTRONICALLY
 SIGNED.
 THE DIGITAL STAMP REPRESENTATION IS NOT LEGIBLE AND THE
 NEAME OF DESIGNER IS NOT VISABLE.ON THE FIRST 22
 SHEETS.
  
 UPON ALL 1ST ROUND REVIEWS PLEASE SPEAK TO LIBRARIAN
 ABOUT HOW TO SATISFY SIGNATURE REVIEW.
  
  