| Plan Review Stops For Permit 18091122 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-04-26 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-04-26 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-04-26 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-02-08 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-02-08 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-02-08 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2019-02-08 09:27:38 | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC ENERGY = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 2ND REVIEW 2/8/2019 | | | | | | 1. OK | | | | | | 2. OK | | | | | | 3. NO RESPONSE SHEET WAS PROVIDED, SO I DO NOT KNOW HOW | | | YOUR COMPLYING WITH ENERGY CODE. | | | PLEASE PROVIDE DOCUMENTATION TO SHOW COMPLIANCE WITH | | | ENERGY CODE. | | | 503.3 FBC[CE] BUILDING ENVELOPE. NEW BUILDING ENVELOPE | | | ASSEMBLIES THAT ARE PART OF THE ALTERATION SHALL COMPLY | | | WITH SECTIONS C402.1 THROUGH C402.5. | | | (SEE SECTIONS C402.1 THROUGH C402.5) | | | | | | 4. NO RESPONSE TO FLOORING UNDERLAYMENT. ONLY THE UNIT | | | ON SECOND FLOOR EAST SIDE THAT HAS UNIT BELOW NEEDS | | | UNDERLAYMENT. | | | PLEASE PROVIDE FLOORING SUBMITTAL, OR INDICATE THAT IT | | | WILL BE DEFERRED. | | | | | | PLEASE ADVISE, WHAT FLOORING AND UNDERLAYMENT ARE | | | PROPOSED? PLEASE ADVISE VIA EMAIL. IF THE UNDERLAYMENT | | | PRODUCT PROPOSED IS NOT ONE FOR WHICH WE HAVE TEST | | | REPORTS ON FILE, THE FOLLOWING REPORTS ARE REQUIRED: | | | | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | NOTE: | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-11-07 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-11-07 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-11-06 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2018-11-07 08:20:17 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18091122 | | | REVIEWED: NOVEMBER 7, 2018 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER I | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC ENERGY = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. [FBC 107.3.5.3]MINIMUM DRAWING REQUIREMENTS | | | A FULL REVIEW CANNOT BE DONE WITH THE DRAWINGS | | | PROVIDED. PLEASE PROVIDE DRAWINGS TO SHOW ALL TRADES | | | AND ALL WORK BEING PERFORMED. | | | DEMO PLAN TO SHOW WHAT IS EXISTING AND WHAT IS | | | PROPOSED. | | | LABLE ROOM UNDER THE STAIRS AND NEXT TO GARAGE. IS THAT | | | PART OF FIRST FLOOR UNIT? | | | WHAT IS GOING IN THE KITCHENS? | | | HOW ARE THE SPACES COOLED (SEE COMMENT #3) | | | CURRENT CODES: LIST THE CODES APPLICABLE TO THE WORK | | | BEING PERFORMED. | | | PROJECT DATA: | | | OCCUPANCY = | | | LEVEL OF ALTERATION = | | | TYPE OF CONSTRUCTION = | | | AREA TABULATIONS = | | | WHAT ARE THE CURRENT SEPARATIONS BETWEEN UNITS AND WHAT | | | WILL THEY BE TO MEET CURRENT CODES FOR UNIT SEPARATION? | | | | | | 2. [R302.6]GARAGE CEILING TO HAVE TYPE NOT LESS THAT | | | 5/8? TYPE X OR EQUIVELANT DRYWALL WHEN HABITABLE SPACE | | | IS PROVIDED ABOVE. | | | | | | 3. [FBC ENERGY R401.2]PROVIDE ENERGY CALCULATIONS TO | | | MEET REQUIREMENTS IN R401.2 RESIDENTIAL ENERGY CODE. | | | CHOOSE METHOD IN R401.2 AND SUPPLY DOCUMENTATION. | | | | | | 4. PLEASE ADVISE, WHAT FLOORING AND UNDERLAYMENT ARE | | | PROPOSED? PLEASE ADVISE VIA EMAIL. IF THE UNDERLAYMENT | | | PRODUCT PROPOSED IS NOT ONE FOR WHICH WE HAVE TEST | | | REPORTS ON FILE, THE FOLLOWING REPORTS ARE REQUIRED: | | | | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | NOTE: | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-04-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-04-30 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-04-30 |
Time |
15:56 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-02-25 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-02-25 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-02-25 |
Time |
12:12 |
Sent To |
|
|
| Notes |
| 2019-02-25 15:45:50 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND VALUE | | | OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS IS | | | FOR TOTAL PROJECT, NOT JUST ELECTRICAL. FBC 109.3 (NOT | | | PROVIDED.) | | | | | | NEW COMMENTS: | | | | | | 3. AFCI PROTECTION DESCRIBED IN NOTE 1 IS NOT CODE | | | COMPLIANT. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902; | | | FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE. | | | 4. NOTE 13 STATES THAT LIGHTING IN CLOTHES CLOSETS | | | SHALL COMPLY WITH NEC 4/10.16, WHICH DOESN?T EXIST. | | | PROVIDE CORRECTION. NEC 410.16; FBC RE E4003.12 | | | 5. SHEET E2.1, NOTE 3 CALLS FOR WIRING PER 2011 NEC, | | | WHICH IS NOT THE CURRENT CODE. PROVIDE CORRECTION. FBC | | | PREFACE. | | | 6. PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 FEET OF | | | EACH ROOM USED FOR SLEEPING PURPOSES. FBC RE R315.1 | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-10-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-07 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-07 |
Time |
17:45 |
Sent To |
|
|
| Notes |
| 2018-10-07 17:45:13 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | | SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. WPB | | | FBC 107.2.1, 107.3.5; FS 471 481 | | | 2. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND VALUE | | | OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS IS | | | FOR TOTAL PROJECT, NOT JUST ELECTRICAL. FBC 109.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
N |
Date |
2019-04-25 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-04-25 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-04-25 |
Time |
11:49 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
N |
Date |
2019-02-20 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-02-20 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-02-20 |
Time |
09:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2018-11-19 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-11-19 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-11-19 |
Time |
16:32 |
Sent To |
Z |
|
| Notes |
| 2018-11-19 16:32:57 | ALL INTERIOR WORK NO HISTORIC PRESERVATION JURISDICTION | | | DESPITE CONCERN ABOUT LOS OF PLASTER AND FLOORING. | | | SEDNIGN TO ZONING TO CONFIRM IF 3 APARTMENTS ARE | | | PERMITTED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2019-05-31 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-31 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-21 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2019-05-22 14:21:04 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-14 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-09 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2019-05-09 13:24:30 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-04-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-04-16 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-02-26 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-02-26 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-02-26 |
Time |
11:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-12-04 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-12-04 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-09-25 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2019-05-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-05-30 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-05-30 |
Time |
11:08 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-05-14 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-05-14 |
Time |
14:53 |
Sent To |
P |
|
| Notes |
| 2019-05-14 15:20:54 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #18091122 | | | 4/29/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE 1ST REVIEW COMMENT #3 PRINTED BELOW STILL EXIST- | | | PLEASE COMPLY. | | | | | | 3) M1: INDICATE HOW THE APARTMENTS ARE TO BE | | | VENTILATED- NATURALLY OR MECHANICALLY -AND PROVIDE | | | CALCULATIONS- SEE SECTIONS 401.2, 402.1, AND 403.1 FBC | | | M. (REFER TO SECTION 403.3.2 FBC M FOR ADDITIONAL | | | REQUIREMENTS). PLEASE READ EXPLALNATORY NOTES AND CODE | | | COMPLIANCE REQUIRMENTS BELOW- A & B. | | | | | | A) NATURAL VENTILATION IS ALLOWED FOR BATHROOMS IN | | | SINGLE FAMILY HOMES ONLY, HOWEVER THE PROPOSED PROJECT | | | IS A B (BUSINESS) AND R2 (APARTMENTS) OCCUPANCY WHICH | | | REQUIRES MECHANICAL VENTILATION FOR THE BATHROOMS- SEE | | | SECTION 1203.4.2.1 FBC B. MECHANICAL VENTILATION MOST | | | COMMONLY WOULD BE ACCOMPLISHED USING EXHAUST FANS AND | | | EXHAUST DUCTS IN THE BATHROOMS | | | | | | B) AS PREVIOUSLY REQUESTED PROVIDE CALCULATIONS FOR | | | NATURAL VENTILATION OF THE LIVING SPACES, EXCLUDING THE | | | BATHROOMS- SEE SECTION 402.2 FBC M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-04-29 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-04-29 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2019-04-29 15:03:47 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #18091122 | | | 4/29/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) M1: THE 14 SEER 2-TON AC SYSTEMS DON'T MATCH WITH | | | THE ENERGY CALCULATIONS WHICH INDICATE THE SYSTEMS | | | ARE16 SEER. THE SCHEDULE ALSO DOES NOT PROVIDE A SEER | | | FOR THE MINI SPLIT WHICH IS LISTED AS 18 SEER IN THE | | | ENERGY CALCS. | | | | | | 2) M1 & A4: THE LOUVERD AC CLOSET DOORS SHALL BE OF | | | NON-COMBUSTIBLE CONSTUCTION MATERIALS PER SECTION 602.1 | | | FBC M. THE DOOR SCHEDULE IS INDICATING WOOD. | | | | | | 3) THE 1ST REVIEW COMMENTS #3, 5, 7, 8 PRINTED BELOW | | | STILL EXIST- PLEASE COMPLY. | | | | | | 3) M1: INDICATE HOW THE APARTMENTS ARE TO BE | | | VENTILATED- NATURALLY OR MECHANICALLY -AND PROVIDE | | | CALCULATIONS- SEE SECTIONS 401.2, 402.1, AND 403.1 FBC | | | M. (REFER TO SECTION 403.3.2 FBC M FOR ADDITIONAL | | | REQUIREMENTS). | | | . | | | 5) M1: SHOW HOW LOCAL EXHAUST SYSTEMS ARE BEING | | | PROVIDED FOR THE BATH AND KITCHEN- SECTION 403.3.2.3 | | | FBC M. | | | | | | 7) M2: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | VENTLESS DRYER, AND THE COOKING APPLIANCES- SECTIONS | | | 304.1 AND 504.1 FBC M. | | | | | | 8) M2: CLARIFY IF NEW EXHAUST HOODS FOR THE COOKING | | | APPLIANCES ARE TO BE INSTALLED AND PROVIDE DETAILS AND | | | SPECIFICATIONS- SECTION 505.1 FBC M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2019-02-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-02-20 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-02-20 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2019-02-20 11:30:10 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18091122 | | | 2/20/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | | NEW SYSTEMS IN ACCORDANCE WITH SECTION R403.7.1 FBC EC. | | | | | | 2) THE PROPOSED PROJECT IS CLASSIFIED AS A RENOVATION | | | IN ACCORDANCE WITH SECTION 202 FBC EC. SUBMIT AN ENERGY | | | COMPLIANCE REPORT AS REQUIRED BY SECTION R505.1.1, AND | | | R101.5.1.1 FBC EC | | | | | | 3) INDICATE HOW THE APARTMENTS ARE TO BE VENTILATED- | | | NATURALLY OR MECHANICALLY -AND PROVIDE CALCULATIONS- | | | SEE SECTIONS 401.2, 402.1, AND 403.1 FBC M. | | | | | | 4) THE MODEL NUMBERS ON THE SUBMITTED CUT SHEET FOR THE | | | MINI-SPLIT SYSTEM DO NOT MATCH THE MODEL NUMBERS ON | | | SHEET M1. | | | | | | 5) M-1: SHOW HOW LOCAL EXHAUST SYSTEMS ARE BEING | | | PROVIDED FOR THE BATH AND KITCHEN- SECTION 403.3.2.3 | | | FBC M. | | | | | | 6) M-1: INDICATE WHAT APPLIANCE IS LOCATED IN THE | | | CLOSET BY THE STAIRS. | | | | | | 7) M-2: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | VENTLESS DRYER, AND THE COOKING APPLIANCES- SECTIONS | | | 304.1 AND 504.1 FBC M. | | | | | | 8) M-2: CLARIFY IF NEW EXHAUST HOODS FOR THE COOKING | | | APPLIANCES ARE TO BE INSTALLED AND PROVIDE DETAILS AND | | | SPECIFICATIONS- SECTION 505.1 FBC M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2019-05-31 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-31 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-31 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2019-05-31 13:34:40 | PROVISIO APPROVAL ON 5/14/19 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2019-05-14 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2019-05-14 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2019-05-14 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2019-05-14 16:46:56 | PLUMBING PROVISO WAS AGREED BY MR. DRAGO VIA PHONE | | | CONVERSATION ON 5/14/19 4:30 P.M | | | | | | 1) A CODE COMPLIANT SANITARY ISOMETRIC DRAWING SHALL BE | | | PROVIDE AS A REVISION TO THE BUILDING DEPARTMENT AND | | | APPROVED BY THE 2ND ROUGH/ TOP OUT INSPECTION. THE | | | WASHING MACHINE SHALL NOT DISCHARGE INTO THE BATHROOM | | | GROUP WET VENT. FBC R-P3108.1, P3108.2.1. | | | | | | 2) ANY EXISTING PIPING THAT IS REPLACE SHALL BE INSTALL | | | PER THE 2017 6TH ED FBC AND TREATED AS NEW WORK. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2019-04-18 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-04-18 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-04-18 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2019-04-18 15:04:49 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | WPB CCC = WEST PALM BEACH CROSS CONNECTION CONTROL | | | MANUAL | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 3RD REVIEW | | | PLUMBING COMMENTS: DENIED | | | 1. RE: A-6 PLUMBING PLAN; UNIT #1 & #2 SANITARY RISER. | | | A. GROUND FLOOR; KITCHEN SINK SHALL DISCHARGE TO | | | HORIZONTAL BRANCH DOWNSTREAM OF BATHROOM GROUP PER FBC | | | PL 912.1 AND SHALL BE VENTED PER FBC PL 910.1. | | | B. 2ND FLOOR; NEW CLOTHES WASHER SHALL CONNECT TO | | | VERTICAL STACK BELOW THE SHOWER FIXTURE DRAIN | | | CONNECTION PER FBC PL 912.1.1 AND SHALL BE VENTED PER | | | FBC PL 910.1. | | | C. 2ND FLOOR; KITCHEN SINK AND DISPOSAL SHALL CONNECT | | | TO VERTICAL STACK BELOW THE BATHROOM FIXTURE DRAIN | | | CONNECTIONS PER FBC PL 912.1.1 AND SHALL BE VENTED PER | | | FBC PL 910.1. WATER CLOSET AND BATHTUB FIXTURE DRAINS | | | SHALL CONNECT INDEPENDENTLY TO THE VERTICAL WET VENT. | | | THE BATHTUB FIXTURE DRAIN SHALL CONNECT ABOVE OR AT THE | | | SAME ELEVATION AS THE WATER CLOSET FIXTURE DRAIN. THE | | | DRY-VENT CONNECTION TO THE VERTICAL WET VENT SHALL BE | | | AN INDIVIDUAL OR COMMON VENT SERVING ONE OR TWO | | | FIXTURES. | | | 2.WPB FBC 107.3.5.1.3 REQUIRES A CODE COMPLIANT WATER | | | RISER DIAGRAM. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 | | | | | | 18091122 230 ARGYLE RD | | | | | | NOTE: EXISTING GAS TANKLESS WATER HEATER INSTALLED | | | UNDER PERMIT #16060022 | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-02-26 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-02-26 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-02-26 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2019-02-26 11:11:26 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 2ND REVIEW: DENIED | | | PLUMBING COMMENTS: | | | ORIGINAL SUBMITTAL WAS ONE (1) PLAN SHEET A101, DATED | | | 9/18/2018. PLUMBING SCOPE WAS LIMITED TO REMOVING AND | | | REPLACING EXISTING BATHROOM AND KITCHEN FIXTURES. NEW | | | SUBMITTED PLANS DATED 2/4/2019 SHOW RECONFIGURATION OF | | | BATHROOMS AND KITCHENS AS WELL AS ADDED PLUMBING | | | FIXTURES. | | | PER WPB FBC 107.2.1 AND WPB FBC 107.3.5.3 (12), PROVIDE | | | A CODE COMPLIANT SANITARY PLUMBING RISER DIAGRAM | | | INTEGRATING EXISTING AND NEW PIPING | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | (STAMPED/SEALED AND SIGNED BY DESIGNER OF RECORD IN | | | ACCORDANCE WITH FS 471 FAC 61G15) INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-10-23 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-10-23 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-10-23 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2018-10-23 11:08:47 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 1ST REVIEW: | | | PLUMBING COMMENTS: DENIED | | | | | | 1. REFERENCED THE THE PLANS SUBMITTED FOR CITY OF WEST | | | PALM BEACH PERMIT #17040402. THE BUILDING IN QUESTION | | | APPEARS TO BE THE ONE LOCATED ON THE SOUTH SIDE OF THE | | | PROPERTY. PLEASE PROVIDE THE BOUNDARY SURVEY AND | | | CONFIRM THE BUILDING THAT THE WORK IS TO BE PERFORMED | | | IN. WPB FBC 107.2.1 | | | 2. REVISE PLAN TO PROVIDE OCCUPANCY CLASSIFICATION. WPB | | | FBC 107.2.1 | | | 3. SHOW EXISTING COMMON CLOTHES WASHER FACILITIES FOR | | | RESIDENTS AS REQUIRED BY FBC PL TABLE 403.1. WPB FBC | | | 107.2.12. | | | 4. SHOW LOCATION(S) AND TYPE/CAPACITY OF EXISTING WATER | | | HEATER(S) COMPLYING WITH THE PROVISIONS OF FBC PL | | | CHAPTER 5 AND 607.3, PROVIDING HOT WATER TO FIXTURES AS | | | REQUIRED BY FBC PL 607.1. WPB FBC 107.2.1 | | | 5. PROVIDE WATER HAMMER ARRESTORS AT WATER SUPPLIES TO | | | ICE LINE, DISHWASHER AND CLOTHES WASHER PER FPC PL | | | 604.9; INDICATE SAME ON THE PLANS PER WPB FPC 107.2.1 | | | 6. TUB/SHOWER CONTROL VALVE(S) SHALL BE PRESSURE | | | BALANCED PB,THERMOSTATIC MIXING (TM) OR COMBINATION | | | PB/TM VALVE TYPES WITH HIGH TEMPERATURE LIMITING STOP | | | IN ACCORDANCE WITH FBC PL 424.3 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | (STAMPED/SEALED AND SIGNED BY DESIGNER OF RECORD IN | | | ACCORDANCE WITH FS 471 FAC 61G15) INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-04-25 |
|
|
Cont ID |
|
| Sent By |
aborngra |
Date |
2019-04-25 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
aborngra |
Date |
2019-04-25 |
Time |
11:49 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-02-20 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2019-02-20 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2019-02-20 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-11-20 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2018-11-20 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2018-11-20 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|