| Plan Review Stops For Permit 18091117 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-04-05 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-04-05 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-04-05 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-02-12 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-02-12 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-02-12 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-11-19 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-11-19 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-11-19 |
Time |
10:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-10-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-10-18 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-10-18 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2018-10-18 10:20:02 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT TWO SETS OF SIGNED AND SEALED DRAWINGS. | | | PURSUANT TO FBC 107.1, THE DESIGN MUST BE PREPARED BY A | | | PROFESSIONAL LICENSED PURSUANT TO FS 471. SEE BELOW: | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | | APPLICATION. THE CONSTRUCTION DOCUMENTS SHALL BE | | | PREPARED BY A REGISTERED DESIGN PROFESSIONAL WHERE | | | REQUIRED BY CHAPTER 471, FLORIDA STATUTES & 61G15 | | | FLORIDA ADMINISTRATIVE CODE. WHERE SPECIAL CONDITIONS | | | EXIST, THE BUILDING OFFICIAL IS AUTHORIZED TO REQUIRE | | | ADDITIONAL CONSTRUCTION DOCUMENTS TO BE PREPARED BY A | | | REGISTERED DESIGN PROFESSIONAL. | | | | | | 2) PROVIDE DETAILS, DIMENSIONS, BOTTOM SLOPE, SWIMOUTS, | | | ETC. TO SHOW THAT THE PROPOSED POOL COMPLIES WITH THE | | | REQUIREMENTS OF FBC-R 4501.6 AND ANSI/APSP/ICC 5 - 11. | | | | | | 3) SUBMIT TWO SETS THE MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS AND LISTING FOR THE PROPOSED POOL BARRIER | | | FENCE. FBC-R 4501.17 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-11-19 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-11-19 |
Time |
07:03 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-11-19 |
Time |
06:38 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-10-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-10-10 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-10-10 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2018-10-18 10:59:45 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PROVIDE CUT SHEETS ON POOL LIGHT AND POOL PUMP. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-10-09 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-10-09 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-10-09 |
Time |
06:56 |
Sent To |
|
|
| Notes |
| 2018-10-09 06:57:20 | THERE IS NO HEATER ON THIS POOL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-04-05 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-04-05 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-04-01 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2019-04-03 09:12:47 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-02-12 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-02-12 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-02-04 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2019-02-05 14:46:27 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-11-19 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-11-19 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-30 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2018-10-31 16:18:11 | RESUB ROUTED TO ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-10-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2018-10-18 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2018-09-25 |
Time |
14:08 |
Sent To |
I |
|
| Notes |
| 2018-09-26 14:08:37 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2019-04-05 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-04-05 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-04-05 |
Time |
08:55 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2019-02-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2019-02-12 |
Time |
05:27 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2019-02-12 |
Time |
04:27 |
Sent To |
|
|
| Notes |
| 2019-02-12 05:09:10 | 1) THE TDH CALCULATIONS MUST INCLUDE ALL OF THE SYSTEM | | | COMPONENTS INCLUDING FITTINGS, VALVES, AND CHLORINATOR. | | | ALL SYSTEM COMPONENTS EXCEPT THE PUMP. THE TDH | | | CALCULATIONS DO NOT APPEAR TO HAVE INCCLUDED THESE | | | COMPONENTS. THE PIPE AND FITTINGS FOR THE TANNING LEDGE | | | MUST ALSO BE INCLUDED IN THE TDH CALCULATIONS.THE | | | SIMPLIFIED METHOD IS NO LONGER PERMITTED TO BE USED. | | | CLARIFY.2ND REQUEST.ANSI/APSP/ICC 7-2013 | | | SECS.4.4.9,4.4.9.1. | | | 2) SUBMIT TWO LEGIBLE COPIES OF THE CLEAR COMFORT | | | SANITATION. | | | 3) THE POOL PLANS DRAWN BY THE POOL CONTRACTOR SHALL BE | | | SIGNED AND SEALED BY AN ENGINEER PER FBC 107.1. | | | 4) THE PLANS DRAWN BY THE POOL CONTRACTOR SHOW RETURN | | | LINES FOR THE TANNING LEDGE BUT WHERE IS THE MAIN | | | DRAIN/ SUCTION LINE FOR FILTERING THE WATER? | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-11-16 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-11-16 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-11-16 |
Time |
06:23 |
Sent To |
|
|
| Notes |
| 2018-11-16 14:01:05 | 1) PAGE 7 OF THE LATHAM POOL PRODUCT DRAWINGS REFERS TO | | | THE 2007 FLORIDA BUILDING CODE. THE CODE IN EFFECT IS | | | THE 2017 EDIRION AND THE SECTION REFERENCED ON THE PLN | | | ( SEC. 424) IS WRONG. | | | 2) REMOVE ALL OLD AND MULTIPLE COPIES OF DOCUMENTS FROM | | | THE PERMIT PACKAGE AND COMPILE THE DOCUMENTS INTO TWO | | | COMPLETE SETS OF PLANS FOR REVIEW. WPB AMEND. TO FBC | | | SEC. 107.1. | | | 3) SUBMIT TWO COPIES OF LEGIBLE SPECIFICATIONS FOR THE | | | CLEAR COMFORT SANITATION SYSTEM FOR REVIEW. WPB AMEND. | | | TO FBC SEC. 107.2.1. | | | 4) THERE ARE TWO DIFFERENT POOL SPECS IN THE PERMIT | | | PACKAGE THAT SHOW TWO DIFFERENT PUMPS TO BE INSTALLED. | | | CLARIFY. | | | 5) THE TOTAL DYNAMIC HEAD CALCULATIONS DO NOT SHOW THE | | | FRICTION LOSS FOR ALL THE SUCTION AND RETURN FITTINGS | | | OR VALVES. SUBMIT NEW CALCULATIONS INCORPORATING THE | | | FRICTION LOSS FOR THE VALVES AND FITTINGS. APSP 7-2013 | | | SEC.4.4.9, 4.4.9.1. | | | 6) IDENTIFY ON THE PUMP CURVE THAT IS ON THE TDH | | | CALCULATION SHEET WHICH CURVE KEY APPLIES TO THIS | | | INSTALLATION. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-10-09 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-10-09 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-10-09 |
Time |
05:56 |
Sent To |
|
|
| Notes |
| 2018-10-09 06:18:37 | 1) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE | | | MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM | | | ITS PUMP CURVE IS NO LONGER ALLOWED TO BE USED IN | | | DETERMINING MAXIMUM SYSTEM FLOW RATE PER ANSI/APSP/ICC | | | 7 - 2013 SECS. 4.4.9, 4.4.9.1. THE 2013 EDITION | | | ADDRESSES FLOW RATE IN GALLONS PER MINUTE (GPM). IT | | | REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES NOT EXCEED | | | THE LISTED MAXIMUM FLOW RATE OF THE SUCTION OUTLET | | | FITTING ASSEMBLY (DRAIN COVER).THE TDH CALCULATIONS | | | MUST INCLUDE ALL OF THE SYSTEM COMPONENTS INCLUDING | | | SUCTION AND RETURN PIPING, FITTINGS, VALVES, HEATER, | | | FILTER, AND CHLORINATOR. ALL SYSTEM COMPONENTS EXCEPT | | | THE PUMP. | | | 2) SUBMIT TWO LEGIBLE COPIES OF THE POOL PUMP CURVE. | | | IDENTIFY ON THE PUMP CURVE WHICH CURVE KEY IS SPECIFIC | | | TO THE PUMP BEING INSTALLED ON THIS POOL. THIS IS | | | NEEDED TO CONFIRM THE MAXIMUM SYSTEM FLOW FROM THE TDH | | | CALCULATIONS. | | | 3) INDICATE ON THE PUMP CURVE WHICH CURVE KEY IS FOR | | | THE PUMP BEING INSTALLED ON THIS SYSTEM. WPB AMEND. TO | | | FBC SEC. 107.2.1. | | | 4) SIZE ALL PIPES ON THE PLUMBING DETAIL PLAN. 2017 FBC | | | 107.2.1. | | | 5) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE MAIN | | | DRAIN, PUMP & FILTER. FBC 107.2.1. | | | 6) FILL IN ALL INFORMATION FOR THE POOL UNDER THE | | | "SPECIFICATIONS" HEADING. FBC 107.2.1. | | | 7) THE POOL PLANS SHALL BE SIGNED AND SEALED BY AN | | | ENGINEER PER FBC 107.1. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2019-04-04 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2019-04-04 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2019-04-04 |
Time |
09:22 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-02-06 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2019-02-06 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2019-02-06 |
Time |
14:46 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-11-07 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-11-07 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-11-07 |
Time |
09:20 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-10-02 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-10-02 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-10-02 |
Time |
15:09 |
Sent To |
|
|
| Notes |
|
|