| Plan Review Stops For Permit 18091064 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-03-23 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-03-23 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-23 |
Time |
09:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2019-01-22 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-01-22 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-01-22 |
Time |
12:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-11-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-11-21 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-11-20 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2018-11-21 14:50:14 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18091064 | | | REVIEWED: NOVEMBER 20, 2018 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER I | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC ENERGY = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | [FBC AMENDED 105]PROVIDE SEPARATE PERMIT APPLICATION | | | FOR THE MODULAR BUILDING. IT IS ON A SEPARATE PARCEL | | | WITH A SEPARATE ADDRESS. THE PLANS CAN CONTAIN DRAWINGS | | | FOR BOTH BUILDINGS AS PROVIDED, OR THEY CAN SPLIT UP. | | | | | | TWO REVIEWS ARE PROVIDED BELOW. THE FIRST IS FOR THE | | | NEW STRUCTURE AND THE SECOND IS FOR THE EXISTING LEVEL | | | 3 ALTERATION. | | | | | | REVIEW FOR NEW STRUCTURE CONTAINING KILNS: | | | | | | 1. [FBC AMENDED 107.3.5] | | | LIST PROJECT DATA SEPARATE FOR EACH BUILDING. | | | INCLUDE SPRINKLED OR NON-SPRINKLED | | | CONSTRUCTION TYPE OF EACH BUILDING | | | FIRE RESISTANCE RATING FOR NEW STRUCTURE | | | | | | 2. [FBC 453.8.3.1]THE MINIMUM CONSTRUCTION TYPE FOR | | | ONE- AND TWO-STORY PUBLIC EDUCATIONAL FACILITIES SHALL | | | BE NONCOMBUSTIBLE TYPE I, II OR IV CONSTRUCTION OR | | | BETTER. | | | | | | 3. [FL STATUTE 553] IS THIS A MANUFACTURED BUILDING | | | THAT HAS APPROVALS? | | | IF SO PROVIDE COPY OF BUILDING INSTALLATION AND DETAILS | | | OF FOUNDATION CONNECTION, AND ADA RAMP AS APPLICABLE TO | | | THE NEW STRUCTURE. | | | IF PRE-FAB MEANING PRE CAST WALL PANELS THAN PROVIDE | | | THE PLANS WITH ENGINEERING OF HOW THE STRUCTURE MEETS | | | REQUIREMENTS OF FBC CHAPTER 16. | | | FOUNDATION PLAN, SECTION AND ROOF PLAN WILL ALSO BE | | | NEEDED. | | | | | | | | | 4. [FBC 453.8.3.1]THE MINIMUM CONSTRUCTION TYPE FOR | | | ONE- AND TWO-STORY PUBLIC EDUCATIONAL FACILITIES SHALL | | | BE NONCOMBUSTIBLE TYPE I, II OR IV CONSTRUCTION OR | | | BETTER. | | | | | | 5. [FBC TABLE 602]SHOW FIRE SEPARATION DISTANCE BASED | | | ON NEW STRUCTURE CONSTRUCTION TYPE AND FIRE RESITANCE | | | REQUIREMENTS BASED ON TABLE 601. | | | FIRE SEPARATION DISTANCE IS THE DISTANCE MEASURED FROM | | | THE BUILDING FACE TO ONE OF THE FOLLOWING: 1) THE | | | CLOSEST INTERIOR LOT LINE; 2) TO THE CENTERLINE OF A | | | STREET, ALLEY OR PUBLIC WAY; OR 3) TO AN IMAGINARY LINE | | | BETWEEN TWO BUILDINGS ON THE LOT. THE DISTANCE SHALL BE | | | MEASURED AT RIGHT ANGLES FROM THE FACE OF THE WALL. | | | | | | 6. [FBC TABLE 705.8]MAXIMUM AREA OF EXTERIOR WALL | | | OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE | | | OF OPENING PROTECTION. | | | PROVIDE AMOUNT OF WALL OPENING BASED OFF OF FIRE | | | SEPARATION FROM PREVIOUS COMMENTS AND ADJUST PLANS AS | | | NEEDED TO MEET THE OPENING REQUIREMENTS FOR DOUBLE | | | DOORS AND LOUVERS FACING EXISTING BUILDING. | | | | | | 7. [FBC 453.7.4]COMMON FIRE ALARM. BUILDINGS WITHIN 60 | | | FEET | | | (18,288 MM) OF EACH OTHER SHALL HAVE A COMMON FIRE | | | ALARM | | | SYSTEM. | | | IS THERE AN EXISTING FIRE ALARM AND WILL THERE BE ONE | | | IN THE NEW BUILDING? | | | | | | 8. [FBC 453.12.1]CLASS A MATERIALS. ALL ROOFING | | | MATERIALS SHALL BE | | | LABELED CLASS A PER ASTM E108 | | | WHAT ROOF CLASS IS THE NEW BUILDING? | | | | | | 9. [FL.STATUTE 553.842]PROVIDE PRODUCT APPROVAL FOR | | | LOUVERS USED FOR HEAT VENTILATION, OR INDICATE THAT IT | | | WILL BE DEFERRED. | | | | | | 10. [FBC AMENDED 107.3.4.1]PROVIDE PRODUCT APPROVALS | | | FOR ROOFING, OR INDICATE THAT YOU WOULD LIKE THEM | | | DEFERED. | | | | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | | | | LEVEL 3 ALTERATION EXISTING BUILDING: | | | | | | 11. [FBC AMENDED 107.3.5] | | | LIST PROJECT DATA SEPARATE FOR EACH BUILDING. | | | INCLUDE SPRINKLED OR NON-SPRINKLED | | | CONSTRUCTION TYPE OF EACH BUILDING | | | FIRE RESISTANCE RATING FOR EXISTING STRUCTURE | | | | | | 12. [FBC TABLE 602]SHOW FIRE SEPARATION DISTANCE. | | | IS THE NEW ROLL-UP TO BE FIRE RATED BASED ON | | | SEPARATION? | | | 13. [FBC 705.2.3]COMBUSTIBLE PROJECTIONS. COMBUSTIBLE | | | PROJECTIONS | | | EXTENDING TO WITHIN 5 FEET (1524 MM) OF THE LINE USED | | | TO DETERMINE THE FIRE SEPARATION DISTANCE SHALL BE OF | | | NOT | | | LESS THAN 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION. | | | IS AWNING COMBUSTIBLE? | | | | | | 14 [FBC TABLE 705.2]MINIMUM DISTANCE OF PROJECTION. | | | REVIEW THE PROPOSED AWNING FOR FIRE SEPARTION. | | | IS THE AWNING CROSSING THE PROPERTY LINES? | | | THE PARCELS WOULD NEED UNITY OF TITLE IF STRUCTURES ARE | | | CROSSING OVER LINES. PROVIDE SURVEY TO SHOW EXISTING | | | PROPERTY LINES, EASEMENTS AND PROPOSED/EXISTING | | | STRUCTURES WITHIN. | | | | | | 15. [FBC AMENDED 107.3.5]SHEET A-4, A-6 AND A-7 NEED | | | CO-ORDINATION OF CALL OUTS AND DETAILS. SHEET A-4 CALL | | | -OUT 1/A-6 AT BATHROOM IS OK TO FIND WALL SECTION ON | | | SHEET A-6, BUT MAY NEED TO ADD WALL CALL OUT TO OTHER | | | NEW WALLS AS WELL. ALL OTHER CALL OUTS ARE EITHER | | | MISSING OR DON?T CORRESPOND TO THE CORRECT DETAIL. | | | | | | NOTE: | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-04-17 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-04-17 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-04-17 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-02-06 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-02-06 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-02-06 |
Time |
12:10 |
Sent To |
|
|
| Notes |
| 2019-02-06 14:12:23 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | | | | 2. CORRECTED. | | | | | | 3. CORRECTED. | | | | | | 4. CORRECTED. | | | | | | 5. CORRECTED. | | | | | | 6. CORRECTED. | | | | | | 7. CORRECTED. | | | | | | 8. CORRECTED. | | | | | | 9. CORRECTED. | | | | | | 10. CORRECTED. | | | | | | 11. CORRECTED. | | | | | | 12. CORRECTED. | | | | | | 13. CORRECTED. | | | | | | 14. CORRECTED. | | | | | | NEW COMMENT: | | | | | | 15: ONLY ONE SERVICE IS PERMITTED AND THE MAINS NEED TO | | | BE GROUPED. PROVIDE CORRECTION. NEC 230.2. 230.72 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-10-22 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-10-22 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-10-22 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2018-10-22 12:42:42 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. SHOW WIRE SIZE OF SERVICE OVERHEAD CONDUCTORS COMING | | | OUT OF METER CAN TO POWER UTILITY. FBC 107.2.1 | | | | | | 2. ANNOTATE ON PLAN SIZE OF EXISTING OR NEWLY PROPOSED | | | METER CANS FBC 107.2.1 | | | | | | 3. SERVICE RISER FOR "KILN" BUILDING SHOWS PANEL | | | LABELED AS P-2 AS WELL AS PANEL SCHEDULE BUT PANEL IN | | | BUILDING IS LABLED KB? PROVIDE CORRECTION FBC 107.2.1 | | | | | | 4. SERVICE RECEPTACLE REQUIRED WITH 50' OF SERVICE | | | EQUIPMENT FOR BOTH BUILDINGS. NEC 210.64 | | | | | | 5. WORK AREA EXCEDES 50% OF OF BUILDING AREA, MAKING | | | THIS A LEVEL 3 ALTERATION PER THE FBC EXISTING BUILDING | | | CODE FOR MAIN BUILDING. CODE SUMMARY ON PLAN STATES | | | THIS IS A LEVEL 2 ALTERATION. PROVIDE CORRECTION. FBC | | | 107.2.1 FBC EB 505.1 | | | | | | 6. A SYMBOL IN THE ELECTRICAL LEGEND SAYS "SPECIALTY | | | RECEPTACLE" PLEASE PROVIDE UL/NRTL LISTING OF THESE | | | RECEPTACLES FOR PRODUCT APPROVAL. . | | | | | | 7. PROVIDE UL/NRTL LISTING FOR LIGHT FIXTURES FOR | | | PRODUCT APPROVAL. NEC 90.7, NEC 110.2, NEC 110.3B, FBC | | | 107.2.1 | | | | | | 8. LIGHT NEEDED IN ELECTRICAL ROOM IN MAIN BUILDING. | | | NEC 110.26D | | | | | | 9. SHOW WINDOW RECEPTACLES REQUIRED IN MAIN BUILDING. | | | NEC 210.62 | | | | | | 10. PROVIDE DEDICATED CIRCUIT AND CONTROL FOR EXTERIOR | | | SIGN. NEC 600.5; FBC EC 405.2.4 | | | | | | 11. PROVIDE EXTERIOR LIGHTING CONTROLS AS SPECIFIED IN | | | THE FBC ENERGY CONSERVATION, FOR EGRESS LIGHTINGFBC EC | | | C405.2.5 | | | | | | 12. PROVIDE GRAPH/CALCULATION OF EXTERIOR LIGHTING | | | POWER ALLOWANCES PER THE FBC ENERGY CONSERVATION IN | | | RELATION TO THE CONNECTED EXTERIOR LIGHTING PROPOSED TO | | | COMPLY WITH CODE. FBC EC C405.5.1 | | | | | | 13. MORE THAN 8' OF UNPROTECTED SERVICE CONDUCTOR | | | ENTERING KILN BUILDING FROM METER CAN TO MAIN BREAKER | | | "KB"PANEL. NEC 230.70A | | | | | | 14. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | | EACH PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2017 6TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WPB | | | [email protected] | | | CELL: 561-657-1653 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2019-03-20 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-03-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-03-20 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2019-03-20 11:42:54 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) PROVIDE MANUFACTURE'S SPEC SHEETS FOR THE KILNS TO | | | ENSURE COMPLIANCE WITH INSTALLATION REQUIRMENTS. | | | | | | FIRE INSPECTOR WILL REVIEW ON FIRE INSPECTION. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2019-01-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2019-01-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2019-01-18 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2019-01-18 13:37:03 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) PROVIDE MANUFACTURE'S SPEC SHEETS FOR THE KILNS TO | | | ENSURE COMPLIANCE WITH INSTALLATION REQUIRMENTS. | | | | | | FIRE INSPECTOR WILL REVIEW ON FIRE INSPECTION. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-09-28 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-09-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-09-28 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2018-09-28 11:48:55 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | | | | 1) PROVIDE MANUFACTURE'S SPEC SHEETS FOR THE KILNS TO | | | ENSURE COMPLIANCE WITH INSTALLATION REQUIRMENTS. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-04-26 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-04-26 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-18 |
Time |
14:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-02-19 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2019-02-19 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-01-10 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-11-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-11-21 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-09-25 |
Time |
13:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2019-04-26 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-04-26 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-04-26 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2019-04-26 14:20:31 | NO FEE DUE PER PBC STAMP ON SHEET CS-1 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-11-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-11-21 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-11-21 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2018-11-21 07:46:49 | DYLAN BATTLES | | | BUILDING PLANS EXAMINER I | | | [email protected] | | | 561-805-6718 | | | | | | [FBC AMENDED 109]PLANS WILL BE REVIEWED BY THE PBC | | | IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON | | | NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR | | | WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE | | | WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY | | | UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | | YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE | | | R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU | | | ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE | | | UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-04-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-04-15 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-04-15 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2019-04-15 15:37:39 | MECHANICAL PROVISO: | | | | | | REVISE THE PLAN TO SHOW THE CHANGE TO THE MAKES AND | | | MODELS OF EF-3 & EF-6 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-02-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-02-05 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-02-05 |
Time |
07:08 |
Sent To |
|
|
| Notes |
| 2019-02-05 11:06:30 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #18091064 | | | 2/5/19 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE DESIGN PROFESSIONAL OF RECORD SHALL PROVIDE A | | | SHOP DRAWING STAMP ON THE PLASMA AIR IAQ CALCULATIONS | | | AND SPEC SHEET FOR THE PLASMA AIR IONIZATION UNIT- | | | SECTION 403.2 FBC M. | | | | | | 2) SECOND REQUEST FOR REQUIRED EXHAUST CALCULATIONS, | | | EXHAUST SYSTEMS. AND AIR BALANCE CALCULATIONS. SHEETS | | | M-1 & M-2: EXHAUST VENTILATION SYSTEMS ARE REQUIRED FOR | | | THE ART, WOODWORKING, AND CLAY MIXING ROOMS IN | | | ACCORDANCE WITH TABLE 403.3.1.1 FBC M. | | | | | | ART AND CLAY ROOMS RATES: 0.7 CFMS PER SF, | | | | | | WOODWORKING SHOP: 0.5 CFMS PER SF. | | | | | | REVISE THE PLANS TO SHOW THE REQUIRED SYSTEMS WITH | | | DETAILS ON THE PLANS, PROVIDE EXHAUST AND AIR BALANCE | | | CALCULATIONS, AND THE SEQUENCE OF OPERATIONS FOR THE | | | SYSTEMS- 501.3.2 FBC M. PLEASE SEE FOOTNOTE G UNDER | | | TABLE 403.3.1.1 WHICH LIMITS THE AMOUNT OF AIR THAT CAN | | | BE RECIRCULATED FROM THE AREAS AND ROOMS BEING | | | EXHAUSTED. | | | | | | 3) SECOND REQUEST FOR THE REQUIRED DUST COLLECTION | | | SYSTEM IN THE SHOP. SHEETS M-1 & M-2: CLARIFY HOW DUST | | | COLLECTION AND DISPOSAL WILL BE ACCOMPLISHED IN THE | | | WOODWORKING SHOP. WILL A CENTRAL COLLECTION SYSTEM OR | | | POINT OF USE COLLECTORS BE INSTALLED- SEE SECTION 511 | | | FBC M AND PROVIDE DETAILS. | | | | | | 4) SECOND REQUEST FOR COMPLETE CLAY MIXER EXHAUST | | | SYSTEM DETAILS AND SPECIFICATIONS. M-1 & M-2- CLAY | | | MIXER EXHAUST SYSTEM: PROVIDE EQUIPMENT SCHEDULES ON | | | THE PLAN FOR THE HOOD, FAN, DUCTWORK AND TERMINATION | | | CAP, AND SUBMIT MANUFACTURER'S SPECS. C) SUBMIT FL. | | | PRODUCT APPROVAL #11695 FOR THE ROOF EXHAUST FAN. D) | | | INDICATE HOW REQUIRED MAKE UP AIR FOR THE EXHAUST HOOD | | | IS BEING PROVIDED- SECTION 501.4 FBC M. | | | | | | 5) SUBMIT MANUFACTURER'S SPECIFICATIONS AND | | | INSTALLATION INSTRUCTIONS FOR THE CLAY MIXER, AND THE | | | AF-1 & 2 AIR SCRUBBERS- SECTION 304.1 FBC M. | | | | | | 6) SHOW THE LOCATIONS OF ALL EXHAUST OUTLETS ON THE | | | PLANS WITH CLEARANCE DISTANCE MEASURMENTS TO PROPERTY | | | LINES, OPERABLE AND MECHANICAL OPENINGS INTO THE | | | BUILDING, AND FROM ADJOING GRADES- SECTION 501.3.1 FBC | | | M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-11-09 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-11-08 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-11-08 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2018-11-09 15:57:34 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18091064 | | | 11/8/2018 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS M-1, & M-2: REFER TO SECTION 809.2 FBC EX AND | | | PROVIDE MINIMUM VENTILATION CALCULATIONS FOR ALL ROOMS | | | AND SPACES PER TABLE 403.3.1.1 FBC M. PROVIDE A | | | SCHEDULE THAT INDICATES THE REQUIRED AND PROVIDED CFMS | | | OF OUTDOOR AIR. | | | | | | 2) M-1 & M-2: PROVIDE THE MAKES AND MODELS AND COOLING | | | AND HEATING CAPACITIES OF THE EXISTING RTU'S, AND | | | INDICATE THE CFMS AT EACH DIFFUSER SHOWN ON THE PLAN. | | | PLEASE NOTE THAT A TEST AND BALANCE REPORT MAY BE DUE | | | AT FINAL INSPECTION | | | | | | 3) M-1 & M-2: EXHAUST VENTILATION SYSTEMS ARE REQUIRED | | | FOR THE ART, WOODWORKING, AND CLAY MIXING ROOMS IN | | | ACCORDANCE WITH TABLE 404.3.1.1 FBC M. | | | | | | ART AND CLAY ROOMS RATES: 0.7 CFMS PER SF, | | | | | | WOODWORKING SHOP: 0.5 CFMS PER SF. | | | | | | REVISE THE PLANS TO SHOW THE REQUIRED SYSTEMS WITH | | | DETAILS ON THE PLANS, PROVIDE EXHAUST AND AIR BALANCE | | | CALCULATIONS, AND THE SEQUENCE OF OPERATIONS FOR THE | | | SYSTEMS- 501.3.2 FBC M. PLEASE SEE FOOTNOTE G UNDER | | | TABLE 403.3.1.1 WHICH LIMITS THE AMOUNT OF AIR THAT CAN | | | BE RECIRCULATED FROM THE AREAS AND ROOMS BEING | | | EXHAUSTED. | | | | | | 4) M-1 & M-2: PROVIDE AN EQUIPMENT PLAN AND A | | | CORRESPONDING EQUIPMENT SCHEDULE- SECTION 107.2.1 WPB. | | | | | | 5) M-1 & M-2: CLARIFY HOW DUST COLLECTION AND DISPOSAL | | | WILL BE ACCOMPLISHED IN THE WOODWORKING SHOP. WILL A | | | CENTRAL COLLECTION SYSTEM OR POINT OF USE COLLECTORS BE | | | INSTALLED- SEE SECTION 511 AND PROVIDE DETAILS. | | | | | | 6) M-1 & M-2- CLAY MIXER EXHAUST SYSTEM: A) PROVIDE | | | DESIGN CRITERA- INDICATE WHICH STANDARD OR CODE USED, | | | DESIGNED PER MANUFACTURER'S SPECIFICATIONS. . B) | | | PROVIDE EQUIMENT SCHEDULES ON THE PLAN FOR THE HOOD, | | | FAN, DUCTWORK AND TERMINATION CAP, AND SUBMIT | | | MANUFACTURER'S SPECS. PLEASE NOTE THAT FL#11697 CALLED | | | OUT IN THE NOTES IS A PRODUCT APPROVAL FOR A GRAVITY | | | RELIEF CAP, HOWEVER THIS IS APPEARS TO BE A FORCED | | | DRAFT SYSTEM. C) PROVIDE ENLARGED, DIMENSIONED FRONT | | | AND PLAN VIEW DRAWINGS FOR THE EXHAUST HOOD SHOWING | | | REQUIRED CLEARANCE DISTANCE MEASUREMENTS, THE TOTAL AND | | | SEGMENTED LENGTHS OF THE EXHAUST DUCTWORK AND HOW THE | | | HOOD, FAN, AND DUCTWORK WILL BE SUPPORTED. | | | | | | 7) M1 & M2- PRE-FAB KILN ROOM: SUBMIT A FL. PRODUCT | | | APPROVAL OR STATE CERTIFICATION LETTER FOR THE ROOM TO | | | VERIFY WIND LOAD COMPLIANCE AND IMPACT RATING OF THE | | | STRUCTURE AND DOORS. CLARIFY IF THE AIROLITE LOUVERS | | | ARE FACTORY OR FIELD INSTALLED AND SUBMIT THE FL. | | | PRODUCT APPROVAL # 16746.1 THAT IS CALLED OUT ON THE | | | PLAN. PLEASE NOTE THAT THE VENTILATION LOUVERS MUST | | | ALSO BE COMPLIANT WITH THE AMCA 550 FOR WEATHER | | | RESISTANCE PER SECTION 401.5. A) PROVIDE EQUIPMENT | | | SCHEDULES ON THE PLAN FOR THE KILNS AND SUBMIT | | | MANUFACTURER'S SPECIFICATIONS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | 2018-11-08 11:59:24 | DID NOT REVIEW WENT IN WRONG PERMIT# |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2019-04-11 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-04-11 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-04-11 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2019-04-11 10:31:46 | APPROVED | | | PROVISO | | | 1. SIGNED AND SEALED LETTERS (TWO COPIES) PROVIDING | | | ROOF DRAIN CALCULATIONS SHALL BE SUBMITTED AS DEFERRED | | | SUBMITTAL AS ALLOWED BY WPB FBC 107.3.4.1. APPROVED | | | SUBMITTAL SHALL BE IN PLACE PRIOR TO THE FIRST | | | INSPECTION. | | | 2. REFER TO RED LINED COMMENT ON P-2 SANITARY RISER AND | | | P-1 FLOOR PLAN AT THE WATER CLOSETS. VENT SHALL RISE | | | VERTICALLY ABOVE CENTER LINE OF HORIZONTAL DRAIN PER | | | FBC PL 905.3 AND 905.4. | | | 3. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S | | | APPROVAL | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2019-01-29 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-01-29 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-01-29 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2019-01-29 12:49:42 | CODES IN EFFECT: | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 5TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | PLUMBING COMMENTS: DENIED | | | 1. EWH-1: PROVIDE ON DETAIL OF WATER HEATER THE THERMAL | | | EXPANSION CONTROL DEVICE AND THE SIZE OF SAID DEVICE IN | | | ACCORDANCE WITH FBC PL 607.3 PER WPB FPC 107.2.1. | | | 2. THE ADDED SERVICE SINK (TAG P-6) IS NOT SHOWN ON THE | | | PLUMBING FLOOR PLAN PAGE P-1. PLEASE SHOW ON FLOOR | | | PLANS P-1 AS WELL AS ON A-4 PER WPB FBC 107.2.1. THE | | | PLUMBING FIXTURES AS SHOWN ON THE ARCHITECTURAL FLOOR | | | PLAN A-4, PLUMBING FLOOR PLAN P-1 AND PLUMBING PLAN | | | SHEET P-2 SHOULD ALL MATCH IN QUANTITY AND APPROXIMATE | | | LOCATION/CONFIGURATION. PLEASE RECONCILE DRAWINGS PER | | | WPB FBC 107.2.1. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | SINCERELY, | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | 561-805-6715 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-11-08 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-11-08 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-11-08 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2018-11-08 13:35:55 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 1ST REVIEW: DENIED | | | COMMENTS: | | | 1. RE: PLAN SHEET P-2; PLUMBING FIXTURE | | | SCHEDULE/REQUIREMENTS: | | | A. BASED ON OCCUPANT LOAD OF 39+ FOR OCCUPANCY B, A | | | SERVICE SINK IS REQUIRED PER FBC PL TABLE 403.1 | | | B. EWH-1: REMARKS; HOW DOES REMARK ?OPTIONAL METAL | | | HANDLE, VACUUM BREAKER? APPLY? PLEASE CLARIFY. | | | C. P-4: DOES THE FAUCET SPOUT FOR THE SINK HAVE HOSE | | | THREAD OUTLET? IF SO, A VACUUM BREAKER IS REQUIRED. | | | PLEASE CLARIFY. | | | D. P-4: IS ADA COMPLIANCE FOR THIS FIXTURE REQUIRED BY | | | FBC ACC? IF SO, ARCHITECT SHALL NOTE AND ADDRESS ON THE | | | ARCHITECTURAL PLANS PER WPB FBC 107.2.1. ADDITIONALLY, | | | IT SHALL BE CONFIRMED THAT A PARALLEL APPROACH | | | COMPLYING WITH FBC ACC 305 IS PERMITTED UNDER FBC ACC | | | 606.2 PER WPB FBC 107.2.1. | | | E. P-4: ADA COMPLIANT DRINKING FOUNTAIN SHALL BE NOTED | | | AND ADDRESSED ON THE ARCHITECTURAL PLANS PER WPB FBC | | | 107.2.1. | | | 2. PLAN SHEET P-1 NOTE 4 CALLS FOR AN INSTA-HOT | | | TANKLESS WATER HEATER AND A TEMPERATURE LIMITING DEVICE | | | CONFORMING TO ASSE 1070 FOR EACH OF THE TOILET ROOMS. | | | PLAN SHEET P-2 WATER RISER DIAGRAM SHOWS HOT WATER | | | SUPPLIED TO THE LAVATORIES IN THE TOILET ROOMS BEING | | | FURNISHED BY EWH-1 THROUGH THE TEMPERATURE LIMITING | | | DEVICE. PLEASE CLARIFY. | | | A. BEAR IN MIND THAT PER FBC PL 607.2, HOT WATER PIPING | | | EXCEEDING 50? FROM THE HOT WATER SOURCE SHALL BE | | | RECIRCULATED OR HEAT TRACED. | | | 3. HOT WATER SHALL BE INSULATED IN ACCORDANCE WITH FBC | | | EC C404.4. | | | 4. EWH-1: PROVIDE DETAIL OF WATER HEATER SHOWING HEATER | | | W/STORAGE CAPACITY, PIPING INCLUDING CW, HW, VALVING, | | | THERMAL EXPANSION CONTROL DEVICE, T&P DISCHARGE | | | (INCLUDING TERMINATION) AND WATER HEATER PAN AND DRAIN | | | (INCLUDING TERMINATION) PER WPB FPC 107.2.1; COMPLY | | | WITH FBC PL 607.3, 503.1, 504.1, 504.4, 504.4.1, 504.5, | | | 504.6, 504.7, 504.7.1 AND 504.7.2. | | | 5. PLAN SHEET P-2 WATER RISER DIAGRAM NOTES NEW ?? HW | | | CONNECTING TO EXISTING CW. PLEASE CLARIFY. | | | 6. RE: PLAN SHEET P-2 SANITARY RISER DIAGRAM; | | | A. PROVIDE VENT FOR EACH OF THE TWO WATER CLOSET | | | FIXTURE DRAINS CONNECTING DIRECTLY TO THE BUILDING | | | DRAIN PER FBC PL 909.1 TO COMPLY WITH THE REQUIREMENTS | | | OF FBC PL CHAPTER 9. | | | B. PROVIDE VENT FOR EACH OF THE THREE FIXTURE DRAINS | | | FOR THE LAVATORIES AND DRINKING FOUNTAIN PER FBC PL | | | 909.1 TO COMPLY WITH THE REQUIREMENTS OF FBC PL CHAPTER | | | 9. | | | 7. RE: PLAN SHEET P-2 MATERIAL NOTES: 22 11 16 DOMESTIC | | | WATER. NOTE 2; CHANGE THE WORDS ?WATER PIPING BELOW | | | GRADE SHALL BE? TO WORDS ?WATER SERVICE PIPING BELOW | | | GRADE MAY BE?. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-04-26 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2019-04-26 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2019-04-23 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2019-02-19 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2019-02-19 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2019-02-12 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2019-02-19 15:18:32 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 02.19.2019 | | | PERMIT NO.: 18091064 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. THE REVISED PLANS INDICATE A CHAIN-LINK FENCE WITH | | | SCREEN AROUND THE NEW PATIO?THIS DOESN?T MEET THE CODE | | | REQUIREMENTS. A SOLID WALL OR FENCE SUCH AS PVC OR WOOD | | | SHALL BE PROVIDED IN ADDITION TO THE HEDGE. | | | | | | 2. ONE OF MY COMMENTS FROM THE FIRST REVIEW WAS THAT | | | THE CITY COMMISSION AT THE TIME OF ADDING THIS PARCEL | | | INTO THE MASTER PLAN MADE COMMENTS ABOUT PBAU | | | CONSIDERING ADDITIONAL FA?ADE ALTERATIONS (SPECIFICALLY | | | ALONG SOUTH DIXIE HIGHWAY), INCLUDING ADDITIONAL | | | WINDOWS, AWNINGS, ETC. THE RESPONSE PROVIDED SIMPLY | | | INDICATES THAT THE KILN AND AWNING ON THE EAST SIDE | | | WERE REMOVED FROM THE SCOPE?IT DOESN?T ADDRESS THE | | | COMMENT ABOUT NEEDING ADDITIONAL WINDOWS, AWNINGS, ETC. | | | CAN YOU PROVIDE SOME CLARIFICATION? | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-10-10 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2018-10-10 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2018-10-09 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2018-10-10 10:16:54 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 10.09.2018 | | | PERMIT NO.: 18091064 | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. PURSUANT TO COMMENTS BY THE CITY COMMISSION AT THE | | | PUBLIC HEARINGS FOR CONSIDERATION OF ADDING THIS PARCEL | | | TO THE PBAU MASTER PLAN, ADDITIONAL FA?ADE ALTERATIONS | | | SHOULD BE CONSIDERED, INCLUDING ADDITIONAL WINDOWS, | | | AWNINGS, ETC. | | | | | | 2. THE PBAU MASTER PLAN DOES NOT PROVIDE FOR THE | | | CONSTRUCTION OF AN ADDITIONAL BUILDING (PRE-FAB KILN | | | ROOM). A MAJOR AMENDMENT TO THE PBAU COMMUNITY SERVICE | | | PLANNED DEVELOPMENT (CSPD) SHALL BE REQUIRED TO PROVIDE | | | FOR THE ADDITIONAL CONSTRUCTION. AS PART OF THIS | | | APPLICATION, ADDITIONAL IMPROVEMENTS WILL NEED TO BE | | | PROVIDED INCLUDING REQUIRED LANDSCAPING, ETC. | | | | | | 3. ON SHEET A-4 (FLOOR PLAN), WHAT APPEARS TO BE A | | | PROPOSED 6 FOOT CHAIN LINK FENCE AROUND THE PROPOSED | | | KILN ROOM IS IDENTIFIED WITH KEY NOTE #16, WHICH SPEAKS | | | OF INTERIOR WALLS AND DOORS. ENSURE THAT ALL KEY NOTES | | | ARE APPROPRIATELY COORDINATED WITH THE PLAN. | | | | | | 4. AS IT APPEARS THAT THE PATIO BETWEEN THE EXISTING | | | BUILDING AND THE PROPOSED KILN ROOM WILL BE AN OUTDOOR | | | WORK AREA, A SCREEN WALL WITH LANDSCAPING AND OPAQUE | | | GATES SHOULD BE PROVIDED ALONG THE GRUBER PLACE | | | FRONTAGE. | | | | | | 5. ALL IMPROVEMENTS NEED TO BE SHOWN ON THE SITE PLAN, | | | INCLUDING NEW FENCING/WALLS, AWNINGS, ETC. | | | | | | 6. TWO (2) COPIES OF A CURRENT AND ACCURATE SURVEY | | | SHALL BE PROVIDED. THE SURVEY SHALL IDENTIFY ALL | | | EASEMENTS AND OTHER ENCUMBRANCES ON THE PROPERTY. | | | ENSURE THAT THE SURVEY ALSO COVERS THAT AREA WHERE THE | | | PROPOSED KILN ROOM IS TO BE LOCATED. | | | | | | 7. THE PROPOSED GATES SHALL NOT SWING OUTWARD, BLOCKING | | | THE SIDEWALK. | | | | | | 8. PLEASE EXPLAIN THE PURPOSE OF THE GATES ON THE | | | PATIO; ARE THEY FOR VEHICULAR ACCESS? THIS AREA OF THE | | | STREET HAS ON-STREET PARKING?THEREFORE, VEHICULAR | | | ACCESS INTO THIS AREA WOULD NOT BE POSSIBLE. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|