| Plan Review Stops For Permit 18090994 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-12-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-08 |
Time |
18:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-08 |
Time |
18:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-10-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-10-30 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-10-30 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2018-10-30 14:14:40 | 2017 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 18090994 | | | ADD: 2465 MERCER AVE., SUITE:A-205 | | | CONT: SEARCH CONSTRUCTION | | | TEL: 561-346-8191 | | | E-MAIL: [email protected] | | | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. OCT. 30/ 2018 | | | ACTION: DENIED | | | | | | 1) ADDITIONAL INFORMATION IS REQUIRED MISSING FROM THE | | | FLOOR/ LIFE SAFETY PLAN. 107.3.5 MINIMUM PLAN REVIEW | | | CRITERIA FOR BUILDINGS. THE EXAMINATION OF THE | | | DOCUMENTS BY THE BUILDING OFFICIAL SHALL INCLUDE THE | | | FOLLOWING MINIMUM CRITERIA AND DOCUMENTS: | | | 1A) THE MINIMUM BUILDING TYPE? 2017 FBC-B TABLE 504.3 & | | | 504.4. | | | 1B) STORIES THIS BUILDING HAS? 2017 FBC-B TABLE 504.3 & | | | 504.4 | | | 1C) THE ACTUAL SQUARE FOOTAGE FOR EACH STORY? 2017 | | | FBC-B TABLE 504.3 & 504.4 | | | 1D) IS THE BUILDING FIRE SPRINKLERED? 2017 FBC-B TABLE | | | 504.3 & 504.4 | | | 1E) SQUARE FOOTAGE OF THE TENANT SPACE? 2017 FBC-B | | | TABLE 504.3 & 504.4 | | | | | | 2) THE PLANS DOES NOT INDICATE IF THE LOCATION OF THE | | | WATER CLOSET IS A NEW LOCATION REQUIRING A NEW FLOOR | | | PENETRATION AND FIRE RATED FLOOR ASSEMBLIES PER 2017 | | | FBC-B 714.4 HORIZONTAL ASSEMBLIES. PENETRATIONS OF A | | | FIRE-RESISTANCE-RATED FLOOR, FLOOR/CEILING ASSEMBLY OR | | | THE CEILING MEMBRANE OF A ROOF/CEILING ASSEMBLY NOT | | | REQUIRED TO BE ENCLOSED IN A SHAFT BY SECTION 712.1 | | | SHALL BE PROTECTED IN ACCORDANCE WITH SECTIONS 714.4.1 | | | THROUGH 714.4.4. | | | | | | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-12-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-12-07 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-12-07 |
Time |
14:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-10-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-05 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-05 |
Time |
11:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-11-28 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-11-28 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-11-28 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-09-26 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-09-26 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-09-26 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2018-09-26 10:57:56 | PERMIT # 18090994 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | APPROVED PROVISO: | | | | | | 1) UPDATE THE CODE LIST TO REFERENCE THE 6TH EDITION OF | | | THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE | | | 2015 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | | AMENDMENTS. | | | | | | 2) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-01-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-01-07 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2019-01-08 11:38:38 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-01-03 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-01-03 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-11-20 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-10-30 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-10-30 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-09-21 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-10-30 |
Time |
14:17 |
Rev Time |
|
| Received By |
|
Date |
2018-10-30 |
Time |
14:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-01-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-01-11 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-01-11 |
Time |
11:05 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-12-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-12-13 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-12-13 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2018-12-13 15:48:49 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #18090994 | | | 12/13/2018 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | COMMENT #2 FROM THE 1ST REVIEW (PRINTED BELOW) STILL | | | EXISTS- PLEASE COMPLY. | | | | | | 2) THE PERSON WHO PREPARED THE ENERGY/GAUGE CALCULATION | | | FORM AND THE BUILDING'S OWNER SHALL EACH SIGN AND DATE | | | THE FORM ON THE CERTIFICATIONS PAGE- SECTION C103.1.1.2 | | | FBC EC | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-10-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-10-12 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-10-12 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2018-10-12 15:55:38 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18090994 | | | 10/12/2018 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE COOLING AND HEATING CALCULATIONS FOR THE NEW | | | AC SYSTEM- SECTION C403.2.1 FBC-17 EC. | | | | | | 2) THE PERSON WHO PREPARED THE ENERGY/GAUGE CALCULATION | | | FORM AND THE BUILDING'S OWNER SHALL EACH SIGN AND DATE | | | THE FORM ON THE CERTIFICATIONS PAGE- SECTION C103.1.1.2 | | | FBC EC | | | | | | 3) SHEET A-3: PROVIDE MINIMUM VENTILATION CALCULATIONS | | | FOR ALL ROOMS AND SPACES PER TABLE 403.3.1 FBC-17 | | | MECHANICAL. PROVIDE A SCHEDULE THAT INDICATES THE | | | REQUIRED AND PROVIDED CFMS OF OUTDOOR AIR. PLEASE NOTE | | | THAT THE AC EQUIPMENT SCHEDULE IS INDICATING 440 CFMS | | | OF OUTSIDE AIR IS BEING PROVIDED WHICH SEEMS TO BE | | | EXCESSIVE FOR THIS 1066 SF. OFFICE SPACE. | | | | | | 4) A-3: THE AC EQUIPMENT SCHEDULE INDICATES COOLING AND | | | HEATING CAPCITIES FOR THE SYSTEM THAT DON'T MATCH THE | | | COMPLIANCE DATA IN THE ENERGY/GAUGE FORM. THE SCHEDULE | | | INDICATES COOLING AT 30,136 BTUH HOWEVER THE ENERGY | | | CALCS INDICATE 34,000 BTUH. | | | | | | 5) THE AC EQUIPMENT SCHEDULE INDICATES THE TOTAL SUPPLY | | | AIR FOR THE SYSTEM IS 671 CFMS, HOWEVER THE PLAN | | | INDICATES 950 CFMS- PLEASE CORRECT. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-01-03 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-01-03 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-01-03 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2019-01-03 16:05:12 | APPROVED | | | PLUMBING PROVISO | | | 1. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S | | | APPROVAL |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-10-18 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-10-18 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-10-18 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2018-10-18 09:37:17 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 1ST REVIEW: DENIED | | | PLUMBING COMMENTS: | | | | | | 1. RE: A-3; HOT WATER REQUIRED PER FBC PL 607.1. | | | PROVIDE TEMPERED WATER TO LAVATORY IN ACCORDANCE WITH | | | FBC PL 416.5, 607.1.1 AND 607.1.2. | | | A. SHOW LOCATION OF WATER HEATER ON PLAN. PROVIDE WATER | | | HEATER SCHEDULE PER WPB FPC 107.3.5.1.3 (5). IF A | | | STORAGE TYPE WATER HEATER IS SPECIFIED THEN INCLUDE | | | THERMAL EXPANSION CONTROL DEVICE, T&P DISCHARGE( | | | INCLUDING TERMINATION) AND WATER HEATER PAN AND DRAIN | | | (INCLUDING TERMINATION)PER WPB FPC 107.2.1; COMPLY WITH | | | FBC PL 607.3, 503.1, 504.1, 504.4, 504.4.1, 504.5, | | | 504.6, 504.7, 504.7.1 AND 504.7.2. | | | B. PROVIDE SPEC FOR APPROVED WATER-TEMPERATURE LIMITING | | | DEVICE THAT CONFORMS TO ASSE 1070 OR CSA B125.3 FOR | | | LAVATORY. | | | 2. RE: A-3; PLUMBING RISER. SHOW CONNECTION TO SANITARY | | | STACK AT WET COLUMN. | | | 3. RE: A-3; PLUMBING LAYOUT. SHOW CONNECTION TO | | | SANITARY STACK AND LABEL AT WET COLUMN; ELIMINATE | | | CONNECTION OR REFERENCE TO BUILDING SEWER. | | | 4. RE: A-3; PLUMBING NOTE 16. THE NOTE ALLUDES TO GAS | | | PIPING. THERE IS NO PLAN SHOWING GAS PIPING AND NO | | | REVIEW HAS BEEN MADE. IF THERE IS GAS PIPING, AN | | | APPLICATION FOR GAS PERMIT MUST BE SUBMITTED ALONG WITH | | | PLANS COMPLYING WITH FBC FG. IF THERE IS NO GAS PIPING | | | THEN PLEASE REMOVE THE NOTE PER WPB FBC 107.2.1. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | (STAMPED/SEALED AND SIGNED BY DESIGNER OF RECORD IN | | | ACCORDANCE WITH FS 471 FAC 61G15) INTO THE ORIGINAL | | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | | REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|