Plan Review Details - Permit 18090732
Plan Review Stops For Permit 18090732
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-10-03 Cont ID  
Sent By rmcdouga Date 2018-10-03 Time 07:00 Rev Time 0.00
Received By rmcdouga Date 2018-10-03 Time 06:54 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2018-11-02 Cont ID  
Sent By jleahy Date 2018-11-02 Time 12:41 Rev Time 0.00
Received By jleahy Date 2018-11-02 Time 12:41 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-10-12 Cont ID  
Sent By jleahy Date 2018-10-12 Time 09:34 Rev Time 0.00
Received By jleahy Date 2018-10-12 Time 09:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-09-27 Cont ID  
Sent By jleahy Date 2018-09-27 Time 12:34 Rev Time 0.00
Received By jleahy Date 2018-09-27 Time 12:33 Sent To  
Notes
2018-09-27 12:35:11FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 NEED TO SUBMIT CUT CHEETS ON ALL POOL EQUIPMENT. LIGHT,
 PUMP, FILTER.....

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2018-09-28 Cont ID  
Sent By lcrespo Date 2018-09-28 Time 15:58 Rev Time 0.00
Received By lcrespo Date 2018-09-28 Time 15:58 Sent To  
Notes
2018-09-28 16:41:47ELECTRIC HEAT PUMP

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-11-05 Cont ID  
Sent By lcrespo Date 2018-11-05 Time 14:04 Rev Time 0.00
Received By lcrespo Date 2018-11-05 Time 14:04 Sent To  
Notes
2018-10-31 16:08:40RESUB ROUTED TO JLEAHY

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-10-12 Cont ID  
Sent By jleahy Date 2018-10-12 Time 09:34 Rev Time 0.00
Received By jleahy Date 2018-10-04 Time 13:52 Sent To  
Notes
2018-10-05 13:53:00RESUB ROUTED TO LCRESPO

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-10-03 Cont ID  
Sent By rmcdouga Date 2018-10-03 Time 07:01 Rev Time 0.00
Received By rmcdouga Date 2018-09-17 Time 11:28 Sent To  
Notes
2018-09-18 11:28:50ROUTED TO ZONING INBOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2018-11-05 Cont ID  
Sent By lcrespo Date 2018-11-05 Time 14:03 Rev Time 0.00
Received By lcrespo Date 2018-11-05 Time 14:03 Sent To  
Notes
2018-11-05 14:05:0611/05/18 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-10-09 Cont ID  
Sent By lcrespo Date 2018-10-09 Time 06:21 Rev Time 0.00
Received By lcrespo Date 2018-10-09 Time 06:21 Sent To  
Notes
2018-10-09 06:22:2910/09/18 2ND POOL PLUMBING REVIEW**DENIED** WITH
 COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. THE PUMP SHOWN ON THE PLAN IS NOT THE SAME AS
 SUBMITTED PER ENGINEERED PLAN, PLEASE CLARIFY. WPB
 AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
 2. 2ND REQUEST, SUBMIT TWO LEGIBLE COPIES OF THE POOL
 PUMP CURVE. IDENTIFY ON THE PUMP CURVE WHICH CURVE KEY
 IS SPECIFIC TO THE PUMP BEING INSTALLED ON THIS POOL.
 THIS IS NEEDED TO CONFIRM THE MAXIMUM SYSTEM FLOW FROM
 THE TDH CALCULATIONS. ANSI/APSP/ICC 7 - 2013 SECS.
 4.4.9, 4.4.9.1
 3. 2ND REQUEST, PLEASE PROVIDE SPEC SHEET FOR HEAT PUMP
 POOL HEATERS SHALL HAVE A MINIMUM COP OF 4.0 WHEN
 TESTED IN ACCORDANCE WITH AHRI 1160, TABLE 2, STANDARD
 RATING CONDITIONS? LOW AIR TEMPERATURE. A TEST REPORT
 FROM AN INDEPENDENT LABORATORY IS REQUIRED TO VERIFY
 PROCEDURE COMPLIANCE. 2017 FBC-ENERGY? SEC. R 403.10.5
 4. BACKFLOW PREVENTER REQUIRED PER THE CITY OF WEST
 PALM BEACH ORD #2853-95. A PERMIT REQUIRED BY A
 LICENSED CONTRACTOR AND MUST BE CERTIFIED BY UTILITIES
 PRIOR TO FINAL INSPECTION. A DUAL CHECK VALVE MAY BE
 USED IF NO POOL FILL IS INSTALLED AT THE METER AND
 INSTALLED BY UTILITIES WHICH DO NOT REQUIRE A PERMIT SO
 PLEASE CONTACT CITY OF WPB UTILITIES AT 561-822-2240
 FOR FURTHER DIRECTIONS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6720
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-09-28 Cont ID  
Sent By lcrespo Date 2018-09-28 Time 16:42 Rev Time 0.00
Received By lcrespo Date 2018-09-28 Time 16:42 Sent To  
Notes
2018-09-28 16:42:5109/28/2018 1ST POOL PLUMBING REVIEW**DENIED** WITH
 COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE MAIN
 DRAIN, PUMP AND HEAT PUMP. WPB AMENDMENTS TO FBC SEC.
 107.2.1.
  
 2. SUBMIT SPECIFICATIONS FOR THE CARTRIDGE FILTER. WPB
 AMEND. TO FBC SEC. 107.2.1.
  
 3. HEAT PUMP POOL HEATERS SHALL HAVE A MINIMUM COP OF
 4.0 WHEN TESTED IN ACCORDANCE WITH AHRI 1160, TABLE 2,
 STANDARD RATING CONDITIONS ? LOW AIR TEMPERATURE. A
 TEST REPORT FROM AN INDEPENDENT LABORATORY IS REQUIRED
 TO VERIFY PROCEDURE COMPLIANCE. 2017 FBC-ENERGY ? SEC.
 R 403.10.5.
  
 4. SUBMIT TWO LEGIBLE COPIES OF THE POOL PUMP CURVE.
 IDENTIFY ON THE PUMP CURVE WHICH CURVE KEY IS SPECIFIC
 TO THE PUMP BEING INSTALLED ON THIS POOL. THIS IS
 NEEDED TO CONFIRM THE MAXIMUM SYSTEM FLOW FROM THE TDH
 CALCULATIONS. WPB AMENDMENTS TO THE FBC SEC. 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS. (USING THE
 MANUFACTURER?S PERFORMANCE CURVE FOR THE EXISTING PUMP,
 FIND THE FLOW THAT CORRESPONDS TO THE TOTAL DYNAMIC
 HEAD. THIS IS THE ACTUAL FLOW AT WHICH THE PUMP IS
 CURRENTLY OPERATING, WHICH MAY OR MAY NOT MEET TURNOVER
 RATE AND WATER VELOCITY REQUIREMENTS. VERIFY THE ACTUAL
 FLOW RATE IS BETWEEN THE MINIMUM FLOW BASED ON THE
 TURNOVER RATE AND THE MAXIMUM FLOW BASED ON THE WATER
 VELOCITY.)
  
 5. THE DYNAMIC HEAD CALCULATIONS FOR THE MAXIMUM SYSTEM
 FLOW DOES NOT SHOW ALL FRICTION LOSS THROUGH ALL
 COMPONENTS, CHLORINATORS, HEATER, ETC., ON THE HAYWARD
 CALCULATOR CHART. ASSUME THE TOTAL FRICTION LOSS WOULD
 INCLUDE THE PIPE, FITTINGS (90-DEGREE FITTINGS, 45'S,
 TEES) AND ALSO VALVES AND FILTER. WPB AMENDMENTS TO THE
 FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 6. THE SUCTION OUTLET SAFETY COMPLIANCE THAT THE SYSTEM
 FLOW RATE HAS BEEN DETERMINED BY THE MAXIMUM FLOW FROM
 THE PUMP CURVE. THIS METHOD IS NO LONGER PERMITTED BY
 APSP/ANSI-7 2013 EDITION SEC. 4.4.9. TOTAL DYNAMIC HEAD
 CALCULATIONS ARE REQUIRED.
  
 7. BACKFLOW PREVENTER REQUIRED PER THE CITY OF WEST
 PALM BEACH ORD #2853-95. A PERMIT REQUIRED BY A
 LICENSED CONTRACTOR AND MUST BE CERTIFIED BY UTILITIES
 PRIOR TO FINAL INSPECTION. A DUAL CHECK VALVE MAY BE
 USED IF NO POOL FILL IS INSTALLED AT THE METER AND
 INSTALLED BY UTILITIES WHICH DO NOT REQUIRE A PERMIT SO
 PLEASE CONTACT CITY OF WPB UTILITIES AT 561-822-2240
 FOR FURTHER DIRECTIONS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6720
  

Review Stop Z ZONING
Rev No 1 Status P Date 2018-09-25 Cont ID  
Sent By mcruz Date 2018-09-25 Time 16:51 Rev Time  
Received By mcruz Date   Time   Sent To  
Notes
***NONE***