| Plan Review Stops For Permit 18090633 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-04-29 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-04-29 |
Time |
09:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2019-03-18 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-03-18 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-14 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2019-03-18 08:30:27 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18090633 | | | REVIEWED: MARCH 18, 2019 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER PX4191 | | | [email protected] | | | 561-805-6718 | | | | | | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC[B] = FBC BUILDING | | | FBC[EXISTING] = FBC EXISTING BUILDING | | | FBC[A] = FBC ACCESSIBILITY | | | FBC[E] = FBC ENERGY CONSERVATION | | | FBC[R] = FBC RESIDENTIAL | | | | | | 1) 311.3 FBC[R] FLOORS AND LANDINGS AT EXTERIOR DOORS. | | | THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH | | | EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL BE NOT | | | LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A | | | DIMENSION OF NOT LESS THAN 36 INCHES (914 MM) MEASURED | | | IN THE DIRECTION OF TRAVEL. THE SLOPE AT EXTERIOR | | | LANDINGS SHALL NOT EXCEED 1/4 UNIT VERTICAL IN 12 UNITS | | | HORIZONTAL (2 PERCENT). | | | -PLEASE ADD LANDING OUTLINE AND LANDING DIMENSIONS TO | | | FLOOR PLAN. | | | | | | 2) 602 FBC[R] WOOD WALL CONSTRUCTION. | | | -PROVIDE CONNECTOR TYPE AND SPACING FOR BASE PLATE TO | | | FOUNDATION. | | | -PROVIDE CONNECTOR AND SPACING OF LEDGER BOARD AND WALL | | | STUDS TO EXISTING STRUCTURE. | | | | | | 3) 107.3.4 FBC[AMENDED] PREVIOUS COMMENT WAS TO PROVIDE | | | PRODUCT APPROVALS. THE RESPONSE WAS TO SEE NOTE 1A, 2 | | | AND 3. | | | -NOTE 1A HAS NINE DOORS LISTED WITH THE PRODUCT | | | APPROVAL NUMBER LISTED. PLEASE SELECT THE ONE TO BE | | | USED AND PRINT OUT TWO COPIES OF THE PRODUCT APPROVAL. | | | MAKE SURE IT IS APPROVED FOR FLORIDA BUILDING CODE 6 TH | | | EDITION 2017. | | | ALSO, WE NEED TWO COPIES OF THE PRODUCT APPROVAL FOR | | | THE LAUNDRY ROOM DOOR. | | | | | | 3) 602.3(3)TABLE FBC[R] REQUIREMENTS FOR WOOD | | | STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND | | | PRESSURES. | | | -PROVIDE SHEATHING NAIL SIZE AND SPACING FROM TABLE | | | R602.3(3). | | | | | | 4) THIS COMMENT IS NOT FROM THE BUILDING CODE. THIS IS | | | A GENERAL OBSERVATION AND NO RESPONSE IS REQUIRED. | | | -FROM THE LOOK OF LAUNDRY DOOR AND WATER HEATER | | | PLACEMENT I DO NOT SEE HOW YOU WOULD GET TWO APPLIANCES | | | IN THE SPACE. WHEN ONE APPLIANCE IS IN IT BLOCKS THE | | | DOOR AND MAY HINDER THE NEXT APPLIANCE FROM GETTING | | | INTO SPACE. MAYBE MOVE WATER HEATER DOWN OR CONSIDER | | | DOUBLE DOORS. | | | | | | 5) 905.2.2 FBC[R] & 905.1.1 FBC[R] FOR ROOF SLOPES FROM | | | TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) AND | | | LESS THAN FOUR UNITS VERTICAL IN 12 UNITS HORIZONTAL | | | (4:12), DOUBLE UNDERLAYMENT APPLICATION IS REQUIRED. | | | -ADD ROOF PITCH TO PLANS AND ADD NOTE FOR DOUBLE | | | UNDERLAYMENT IS PITCH IS LESS THAN FOUR UNITS VERTICAL | | | IN 12 UNITS HORIZONTAL (4:12) | | | | | | NOTES: | | | | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | -COMMENTS ARE A BRIEF OVERVIEW OF CODE SECTIONS. | | | FURTHER REVIEW OF THE REFERENCED CODE SECTIONS WILL BE | | | REQUIRED. | | | | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-11-08 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-11-08 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-11-07 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2018-11-08 08:29:41 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18090633 | | | REVIEWED: NOVEMBER 7, 2018 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER I | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC EB = FBC EXISTING BUILDING | | | FBC ENERGY = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. [FL. STATUTE 471]DOCUMENTS PREPARED BY AN | | | ARCHITECT/ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE | | | TO BE SIGNED, SEALED, DATED ORIGINALS. | | | PLEASE SIGN AND SEAL A-101 AND A-102(BOTH SETS) | | | | | | 2. [FBC AMENDED 107.3.5] PROJECT DATA: | | | OCCUPANCY = R-3 ? | | | AREA TABULATIONS = STATE WHAT IS EXISTING UNDER AIR | | | AND, PROPOSED NEW AMOUNT AND TOTAL THAT WILL NOW BE | | | UNDER AIR. | | | [FBC EXISTING 501]STATE THE LEVEL OF ALTERATION FOR | | | WORK BEING PERFORMED. | | | STATE CODE EDITION BEING USED FOR ALL TRADES. | | | WE ARE CURRENTLY USING FLORIDA BUILDING CODE(FBC), 6TH | | | EDITION (2017) | | | BASIC WIND SPEED=170 | | | RISK CATEGORY = II ? | | | EXPOSURE CATEGORY = B,C OR D ? | | | BUILDING CLASSIFICATION = ENCLOSED ? | | | MEAN BLDG. HGT. = 0 FT.-0 IN. ? | | | WIND SPEED V ULT = 170 ? | | | WIND SPEED V ASD = 132 ? | | | INTERNAL PRESSURE COEFFICIENT GCPI = +/-0.18 | | | | | | 3. [FBC ENERGY R503.1.1]BUILDING ENVELOPE. BUILDING | | | ENVELOPE ASSEMBLIES THAT ARE PART OF THE ALTERATION | | | SHALL COMPLY WITH SECTION R402.1.2 OR R402.1.4, | | | SECTIONS R402.2.1 THROUGH R402.2.13, R402.3.1, | | | R402.3.2, R402.4.3 AND R402.4.5 | | | | | | 4. [FBC EXISTING 807.2]NEW STRUCTURAL ELEMENTS. | | | NEW STRUCTURAL ELEMENTS IN ALTERATIONS, INCLUDING | | | CONNECTIONS AND ANCHORAGE, SHALL COMPLY WITH THE | | | FLORIDA BUILDING CODE, BUILDING. | | | PROVIDE IN-FILL DETAIL, DOOR/WINDOW BUCK DETAILS AND | | | NEW COVERED LAUNDRY AREA CONSTRUCTION DETAILS. | | | | | | 5. [FBC AMENDED 107.3.4.1]PROVIDE PRODUCT APPROVALS FOR | | | WINDOWS AND DOORS, OR INDICATE THAT YOU WOULD LIKE THEM | | | DEFERED. | | | PROVIDE NEW DOOR/WINDOWS DESIGN PRESSURES AND SIZES. | | | | | | 6. [FBC AMENDED 107.3.5]IF NEW ROOF OVER THE LAUNDRY | | | AREA PROVIDE PRODUCT APPROVAL FOR ROOFING MATERIAL TO | | | BE USED. | | | | | | NOTE: | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2019-03-18 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-03-18 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-03-18 |
Time |
09:33 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-10-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-05 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-05 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2018-10-05 14:34:11 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PER THE WPB AMENDMENTS TO THE FBC, PLAN (EACH SHEET | | | OF BOTH COPIES) IS REQUIRED TO BEAR THE NAME AND BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. PROVIDE CORRECTION. WPB FBC 107.1, 107.2; FS | | | 471, 481 | | | 2. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | | SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. WPB | | | FBC 107.2.1, 107.3.5; FS 471 481 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2018-10-18 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-10-18 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-10-18 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2019-03-07 16:21:41 | THE REQUIREMENT FOR GAS HAS BEEN ELIMINATED. THERE IS | | | NO GAS ON THE SITE. JESMITH 3/7/2019 | | 2018-10-18 14:01:26 | REQUIREMENT FOR GAS IS ON THE PLAN. A REVIEW HAS NOT | | | BEEN MADE AT THIS TIME. APPLICATION FOR GAS PERMIT MUST | | | BE SUBMITTED ALONG WITH PLANS COMPLYING WITH THE | | | FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-04-29 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-04-25 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2019-04-26 15:41:15 | RESUB ROUTED TO DBATTLES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2019-03-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2019-02-28 |
Time |
13:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-11-08 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-11-08 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-09-14 |
Time |
10:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2019-04-29 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-04-29 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-04-29 |
Time |
09:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2018-11-08 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-11-08 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-11-08 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2018-11-08 08:31:07 | DYLAN BATTLES | | | BUILDING PLANS EXAMINER I | | | [email protected] | | | 561-805-6718 | | | | | | [FBC AMENDED 109]PLANS REQUIRE REVIEW BY THE PBC IMPACT | | | FEE OFFICE. CALL (561) 233-5025. UPON APPROVAL, YOU MAY | | | CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR | | | REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF THE | | | RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | | AIRE.PDF | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-03-16 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-03-16 |
Time |
06:15 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-03-16 |
Time |
05:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-10-23 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-10-23 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2018-10-23 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2018-10-22 14:36:36 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1 - NEED MECHANICAL PLAN PER2017 FLORIDA BUILDING CODE | | | - BUILDING SEC 107 | | | | | | 2 - NEED EQUIPMENT SIZING (MANUAL J) PER 2017 FLORIDA | | | BUILDING CODE - ENERGY CONSERVATION SEC R403.7 | | | | | | 3 - NEED COMPLIANCE REPORT PER 2017 FLORIDA BUILDING | | | CODE - ENERGY CONSERVATION SEC R405.4.2.1 | | | | | | | | | CHRIS MONTELLO | | | 561-805-6673 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-03-07 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-03-07 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-03-07 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2019-03-07 16:24:58 | APPROVED | | | ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S | | | APPROVAL |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-10-18 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2018-10-18 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-10-18 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2018-10-18 13:45:55 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 1ST REVIEW: | | | PLUMBING COMMENTS: DENIED | | | | | | 1. WPB FBC 107.3.5.3(12): PROVIDE SANITARY RISER | | | DIAGRAM SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR | | | THE DESIGN IN ACCORDANCE WITH FS 471 & 481.; SHOW HOW | | | THE NEW SANITARY PIPING WILL INTEGRATE WITH EXISTING | | | SYSTEM SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR | | | THE DESIGN IN ACCORDANCE WITH FS 471 & 481. CLOUD NEW | | | WORK. SHOW ALL REQUIRED DRAINS,TRAPS AND VENTS AND SIZE | | | IN ACCORDANCE WITH FBC RES INCLUDING BUT NOT LIMITED | | | TO, CHAPTERS 30, 31 AND 32 . | | | 2. WPB FBC 107.2.1: PLAN A-102 SHOWS RELOCATED WASHER, | | | DRYER AND WATER HEATER OUT SIDE OF MAIN STRUCTURE IN AN | | | AREA THAT MAY PROVIDE AN OVERHANG AND NO EXTERIOR | | | WALLS; PLEASE CLARIFY. PROVIDE MANUFACTURER'S | | | DOCUMENTATION ALLOWING APPLIANCES TO BE INSTALLED IN A | | | WET AREA. | | | 3. FBC RES P2708.4: TUB/SHOWER CONTROL VALVE(S) SHALL | | | BE PRESSURE BALANCED PB, THERMOSTATIC MIXING (TM) OR | | | COMBINATION PB/TM VALVE TYPES WITH HIGH TEMPERATURE | | | LIMITING STOP. | | | 4. FBC RES P2903.5: PROVIDE WATER HAMMER ARRESTORS AT | | | WATER SUPPLIES TO ICE LINE, DISHWASHER AND CLOTHES | | | WASHER. | | | 5. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE DETAILED, QUANTITY ESTIMATES, AND/OR BONA | | | FIDE SIGNED CONTRACTS WITH SCOPE AND VALUE OF WORK, TO | | | INCLUDE ALL MATERIALS AND LABOR. THIS IS FOR TOTAL | | | PROJECT, NOT JUST PLUMBING. WPB FBC 109.3 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | (STAMPED/SEALED AND SIGNED BY DESIGNER OF RECORD IN | | | ACCORDANCE WITH FS 471, 481 & FAC 61G15) INTO THE | | | ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED | | | SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS | | | SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] | | | PHONE 561-805-6715 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2019-03-18 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2019-03-18 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2019-03-18 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2019-03-18 08:33:36 | APPROVED WITH PRODUCT APPROVAL FL5444-R14 | | | ASPHALT ROOF SHINGLES |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-03-11 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2019-03-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2019-03-11 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-03-11 11:51:52 | * SCOPE OF WORK DOES NOT EXCEED 50% VALUE OF THE | | | STRUCTURE. | | | | | | * STRUCTURES IDENTIFIED IN THE SURVEY THAT ENCROACH | | | ONTO THE ADJACENT RIGHT-OF-WAY AND DOES NOT SEEM TO BE | | | COMPLETED BY PERMIT (I.E. FENCE BLOCKING OFF | | | RIGHT-OF-WAY, METAL CONTAINER ENCROACHING INTO ROW) | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-09-28 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2018-09-28 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2018-09-28 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-09-28 16:21:40 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) SHOW IN A SITE PLAN THE SETBACK DISTANCE FROM THE | | | PROPOSED LAUNDRY CLOSET, LOCATED AT THE SOUTHEAST SIDE | | | OF THE RESIDENCE, TO THE PROPERTY LINE(S). | | | | | | NOTES: | | | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * SCOPE OF WORK DOES NOT EXCEED 50% VALUE OF THE | | | STRUCTURE. | | | | | | * STRUCTURES IDENTIFIED IN THE SURVEY THAT ENCROACH | | | ONTO THE ADJACENT RIGHT-OF-WAY AND DOES NOT SEEM TO BE | | | COMPLETED BY PERMIT (I.E. FENCE BLOCKING OFF | | | RIGHT-OF-WAY, METAL CONTAINER ENCROACHING INTO ROW) | | | | | | * ZONE: SF7 | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | |
|
|