Plan Review Details - Permit 18090439
Plan Review Stops For Permit 18090439
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-12-20 Cont ID  
Sent By rmcdouga Date 2018-12-20 Time 09:26 Rev Time 0.00
Received By rmcdouga Date 2018-12-20 Time 09:24 Sent To I
Notes
2018-12-20 09:27:06PROVIDE POOL BARRIER FENCE AND ALARMS AS REQUIRED BY
 FBC-R4501.17.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-09-26 Cont ID  
Sent By rmcdouga Date 2018-09-26 Time 18:57 Rev Time 0.00
Received By rmcdouga Date 2018-09-26 Time 18:36 Sent To  
Notes
2018-09-26 19:01:05PROVIDE POOL BARRIER FENCE AND ALARMS AS REQUIRED BY
 FBC-R4501.17.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-12-05 Cont ID  
Sent By fgiaquin Date 2018-12-05 Time 12:29 Rev Time 0.00
Received By fgiaquin Date 2018-12-05 Time 06:19 Sent To I
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-09-28 Cont ID  
Sent By fgiaquin Date 2018-09-28 Time 06:54 Rev Time 0.00
Received By fgiaquin Date 2018-09-28 Time 06:41 Sent To P
Notes
2018-09-28 06:54:19ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ELECTRICAL PLAN FOR REVIEW AND SIGNED BY
 PERSON RESPONSIBLE FOR DESIGN. (2 COPIES) FS 481.229
 WPB FBC 107.2.1, 107.3.5
  
 2. PROVIDE SUBMITTALS FOR PRODUCT APPROVAL OF POOL
 PUMP, LIGHTING AND ANY OTHER ELECTRICAL EQUIPMENT
 ASSOCIATED WITH POOL. FBC 107.2.1 NEC 110.3B
  
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WPB
 [email protected]
 CELL: 561-657-1653
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2018-09-28 Cont ID  
Sent By lcrespo Date 2018-09-28 Time 17:20 Rev Time 0.00
Received By lcrespo Date 2018-09-28 Time 17:20 Sent To  
Notes
2018-09-28 17:22:51NO GAS EQUIPMENT

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-12-20 Cont ID  
Sent By rmcdouga Date 2018-12-20 Time 09:27 Rev Time 0.00
Received By rmcdouga Date 2018-12-12 Time 13:44 Sent To  
Notes
2018-12-13 13:44:38RESUB ROUTED TO LCRESPO

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-09-28 Cont ID  
Sent By lcrespo Date 2018-09-28 Time 17:20 Rev Time 0.00
Received By lcrespo Date 2018-09-12 Time 14:24 Sent To  
Notes
2018-09-13 14:24:28ROUTED TO ZONING INBOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-12-18 Cont ID  
Sent By lcrespo Date 2018-12-18 Time 14:21 Rev Time 0.00
Received By lcrespo Date 2018-12-18 Time 14:21 Sent To B
Notes
2018-12-18 14:22:4512/18/18 REVIEWED FOR CODE COMPLIANCE
 (PLUMBING/BACKFLOW)
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-09-28 Cont ID  
Sent By lcrespo Date 2018-09-28 Time 17:20 Rev Time 0.00
Received By lcrespo Date 2018-09-28 Time 17:20 Sent To  
Notes
2018-09-28 17:21:5309/28/2018 1ST POOL PLUMBING REVIEW**DENIED** WITH
 COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. THE ADDRESS OF THE PROJECT OR THE RESIDENCE MUST BE
 ON PLAN. WPB AMENDMENTS TO THE FBC SEC.107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 2. SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE MAIN
 DRAIN, PUMP. WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 3. SUBMIT SPECIFICATIONS FOR THE CARTRIDGE FILTER. WPB
 AMEND. TO FBC SEC. 107.2.1.
  
 4. SUBMIT TWO COPIES OF THE POOL PUMP CURVE. IDENTIFY
 ON THE PUMP CURVE WHICH CURVE KEY IS SPECIFIC TO THE
 PUMP BEING INSTALLED ON THIS POOL. THIS IS NEEDED TO
 CONFIRM THE MAXIMUM SYSTEM FLOW FROM THE TDH
 CALCULATIONS. WPB AMENDMENTS TO THE FBC SEC. 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS. (USING THE
 MANUFACTURER?S PERFORMANCE CURVE FOR THE EXISTING PUMP,
 FIND THE FLOW THAT CORRESPONDS TO THE TOTAL DYNAMIC
 HEAD. THIS IS THE ACTUAL FLOW AT WHICH THE PUMP IS
 CURRENTLY OPERATING, WHICH MAY OR MAY NOT MEET TURNOVER
 RATE AND WATER VELOCITY REQUIREMENTS. VERIFY THE ACTUAL
 FLOW RATE IS BETWEEN THE MINIMUM FLOW BASED ON THE
 TURNOVER RATE AND THE MAXIMUM FLOW BASED ON THE WATER
 VELOCITY.)
  
 5. THE DYNAMIC HEAD CALCULATIONS FOR THE MAXIMUM SYSTEM
 FLOW DOES NOT SHOW ALL FRICTION LOSS THROUGH ALL
 COMPONENTS, CHLORINATORS, HEATER, ETC., ON THE HAYWARD
 CALCULATOR CHART. ASSUME THE TOTAL FRICTION LOSS WOULD
 INCLUDE THE PIPE, FITTINGS (90-DEGREE FITTINGS, 45'S,
 TEES) AND ALSO VALVES AND FILTER. WPB AMENDMENTS TO THE
 FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 6. THE SUCTION OUTLET SAFETY COMPLIANCE THAT THE SYSTEM
 FLOW RATE HAS BEEN DETERMINED BY THE MAXIMUM FLOW FROM
 THE PUMP CURVE. THIS METHOD IS NO LONGER PERMITTED BY
 APSP/ANSI-7 2013 EDITION SEC. 4.4.9. TOTAL DYNAMIC HEAD
 CALCULATIONS ARE REQUIRED.
  
 7. BACKFLOW PREVENTER REQUIRED PER THE CITY OF WEST
 PALM BEACH ORD #2853-95. A PERMIT REQUIRED BY A
 LICENSED CONTRACTOR AND MUST BE CERTIFIED BY UTILITIES
 PRIOR TO FINAL INSPECTION. A DUAL CHECK VALVE MAY BE
 USED IF NO POOL FILL IS INSTALLED AT THE METER AND
 INSTALLED BY UTILITIES WHICH DO NOT REQUIRE A PERMIT SO
 PLEASE CONTACT CITY OF WPB UTILITIES AT 561-822-2240
 FOR FURTHER DIRECTIONS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 LUIS A. CRESPO
 PLUMBING INSPECTOR /
 PLUMBING PLAN REVIEW
 AVAILABLE FROM 1:00 PM TO 4:00 PM
 [email protected]
 561-805-6720
  

Review Stop Z ZONING
Rev No 1 Status P Date 2018-09-25 Cont ID  
Sent By mcruz Date 2018-09-25 Time 13:28 Rev Time 0.00
Received By mcruz Date 2018-09-25 Time 13:26 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy