Plan Review Details - Permit 18090399
Plan Review Stops For Permit 18090399
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-11-16 Cont ID  
Sent By pvalenti Date 2018-11-16 Time 15:36 Rev Time 0.00
Received By pvalenti Date 2018-11-16 Time 15:36 Sent To  
Notes
2018-11-16 15:37:56PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 APPROVED PV
  
 NOTE:
 AT TIME OF INSPECTION HAVE PRODUCT APPROVALS FOR NEW
 DOORS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-10-03 Cont ID  
Sent By pvalenti Date 2018-10-03 Time 18:09 Rev Time 0.00
Received By pvalenti Date 2018-10-03 Time 18:09 Sent To  
Notes
2018-10-03 18:21:24****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING :
 1. SECTION (FBC 107.2.1) PAGE A-1.1, GENERAL DESIGN,
 ?BROWARD COUNTY AMENDMENTS? NEEDS TO BE REMOVED FROM
 PLAN IN ADDITION TO ALL OF THE NON-RELATED GENERAL
 NOTES.
 2. SECTION (FBC 1609.4.3) PAGE A-1.1, GENERAL DESIGN
 CRITERIA, WIND EXPOSURE CATEGORY ?C? SHOULD BE CATEGORY
 ?D?.
 3. SECTION (FBC 310.4 & FBC 107.2.1) PAGE A-2.1,
 EXISTING BUILDING INFORMATION SHOWS AN ?R-3? OCCUPANCY
 THAT SHOULD BE AN ?R-2? OCCUPANCY AND THE WORD
 (RESTORATION) LEVEL 2 SHOULD BE CHANGED TO (ALTERATION)
 LEVEL 2.
 4. SECTIONS: (FEB 801.2 & FEB 707.4), (FBC 1609 & FBC
 107.2.1) PAGE A-2.1 EXTERIOR DOOR PRESSURES NEED TO BE
 SHOWN ON PLAN AND IN A SUBMITTED PRODUCT APPROVAL.
 5. SECTIONS: (FBC 107.2.1), (F.S. 481.221), (FAC RULE
 61G1-16.001) ALL PAGES, ARCHITECT?S REGISTRATION NUMBER
 AND SEAL ARE NOT CLEAR.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-09-28 Cont ID  
Sent By jleahy Date 2018-09-28 Time 11:55 Rev Time 0.00
Received By jleahy Date 2018-09-28 Time 11:55 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-10-17 Cont ID  
Sent By scaldero Date 2018-10-17 Time 09:26 Rev Time 0.00
Received By scaldero Date 2018-10-17 Time 09:26 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-09-14 Cont ID  
Sent By scaldero Date 2018-09-14 Time 12:13 Rev Time 0.00
Received By scaldero Date 2018-09-14 Time 12:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By lmarchan Date 2018-10-10 Time 15:45 Sent To I
Notes
2018-10-11 15:45:32B27

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-10-04 Cont ID  
Sent By jesmith Date 2018-10-04 Time 14:42 Rev Time 0.00
Received By jesmith Date 2018-10-04 Time 14:42 Sent To  
Notes
2018-09-13 11:22:41B07

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-11-06 Cont ID  
Sent By jesmith Date 2018-11-06 Time 13:07 Rev Time 0.00
Received By jesmith Date 2018-11-06 Time 13:07 Sent To  
Notes
2018-11-06 13:07:31PLUMBING COMMENTS: APPROVED
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-10-04 Cont ID  
Sent By jesmith Date 2018-10-04 Time 14:35 Rev Time 0.00
Received By jesmith Date 2018-10-04 Time 14:35 Sent To  
Notes
2018-10-04 14:35:30CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 1ST REVIEW:
 PLUMBING COMMENTS: DENIED
  
 1. CONSTRUCTION DOCUMENTS SHALL BE PREPARED BY A
 REGISTERED DESIGN PROFESSIONAL WHERE REQUIRED BY
 CHAPTER 471, FLORIDA STATUTES & 61G15 FLORIDA
 ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA STATUTES &
 61G1 FLORIDA ADMINISTRATIVE CODE. SEAL AND SIGNATURE
 REQUIRED.
 2. PROVIDE PIPING MATERIALS TYPE & FIRE RATED
 ASSEMBLIES FOR NEW OR RELOCATED PIPING FLOOR
 PENETRATIONS PER WPB FBC 107.2.1
 3. RE: PLAN SHEET P-1.0; FIXTURE DRAIN FOR KITCHEN SINK
 SHALL BE PROVIDED WITH AN AIR ADMITTANCE VALVE IN
 ACCORDANCE WITH FBC PL SECTION 918 OR SHALL CONNECT TO
 THE VERTICAL PORTION OF THE EXISTING VENT AND SHALL NOT
 CONNECT BELOW THE WEIR OF THE TRAP PER FBC PL 909.2.
 4. RE: PLAN SHEET P-1.0; FIXTURE DRAIN FOR LAVATORY
 SHALL BE PROVIDED WITH AN AIR ADMITTANCE VALVE IN
 ACCORDANCE WITH FBC PL SECTION 918 OR SHALL CONNECT TO
 THE VERTICAL PORTION OF THE EXISTING VENT AND SHALL NOT
 CONNECT BELOW THE WEIR OF THE TRAP PER FBC PL 909.2.
 UPON REVIEW OF THE DIFFERENCE BETWEEN THE DEMO PLAN
 (A-2.0)AND THE PROPOSED PLAN (A-2.1) IT APPEARS THAT
 THE EXISTING VERTICAL VENT WILL BE DEMOLISHED ALONG
 WITH THE WALL REMOVAL. PLEASE CLARIFY. WPB FBC 107.2.1
 5. RE: PLAN SHEET P-1.0; THIS PROJECT IS NOT CONSIDERED
 RESIDENTIAL (ONE AND TWO FAMILY) AS NOTED IN WPB FBC
 107.3.5.3, BUT PLUMBING AS NOTED IN WPB FBC
 107.3.5.1.3; THEREFORE REFERENCES TO FBC RESIDENTIAL
 CODE SUCH AS P2701, TABLE P3002.1.1 AND P3002.1.2 SHALL
 BE REPLACED WITH APPROPRIATE SECTIONS OF FBC PLUMBING
 CHAPTERS 4 AND 7. ADDITIONALLY THE CHART FOR PLUMBING
 FIXTURE MAXIMUM FLOW RATES SHALL CONFORM TO THE
 REQUIREMENTS OF FBC PLUMBING CHAPTER 6.
 6. RE: PLAN SHEET P-1.0; REPLACE THE NOTE CONCERNING
 THE ANTI-SCALD CONTROL VALVE(S) FOR SHOWERS AND
 BATHTUBS WITH THE FOLLOWING " SHOWER AND COMBINATION
 TUB/SHOWER CONTROLS SHALL BE PRESSURE BALANCED
 PB,THERMOSTATIC MIXING (TM) OR COMBINATION PB/TM VALVE
 TYPES WITH HIGH TEMPERATURE LIMITING STOP. FPC PL
 424.3"
 7. RE: PLAN SHEET P-1.0; PLUMBING NOTE #1. ADD THE WORD
 "PLUMBING" AFTER THE WORD "EDITION". WPB FBC 107.2.1
 8. RE: PLAN SHEET P-1.0; PLUMBING NOTE #10. REPLACE THE
 WORD "CHAMBERS" WITH THE WORDS "HAMMER ARRESTORS". WPB
 FBC 107.2.1, FPC PL 604.9
 9. RE: PLAN SHEET P-1.0; PLUMBING NOTE #5. ADD TO NOTE
 THE WORDS "SHOULD FIELD CONDITIONS WARRANT DESIGN
 CHANGE ' AREVION SHALL BE SUBMITTED TO THE WPB BUILDING
 DEPARTMENT FOR REVIEW FOR COMPLIANCE." WPB FBC SECTION
 105
 10. RE: PLAN SHEET P-1.0; THE SCOPE OF WORK DOES NOT
 SEEM TO INDICATE ANY STORM DRAINAGE WORK. PLEASE REMOVE
 THE NOTE CONCERNING RAINWATER OR SHOW SUCH WORK ON THE
 PLANS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID".
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715