Plan Review Details - Permit 18090395
| Plan Review Stops For Permit 18090395 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2018-10-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-10-24 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-10-24 |
Time |
13:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-09-28 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2018-09-28 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2018-09-28 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2018-09-28 14:18:52 | PLAN PASSED WITH PROVISIONS: | | | | | | SUBMIT PANEL SCHEDULE TO CITY BEFORE FINAL INSPECTION. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-09-14 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-09-14 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-09-14 |
Time |
12:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-12-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-11-21 |
Time |
09:29 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-10-24 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-10-24 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-09-11 |
Time |
11:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2018-10-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2018-10-24 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2018-10-24 |
Time |
13:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-12-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-12-03 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-12-03 |
Time |
16:35 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-10-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-10-05 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-10-05 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2018-10-05 11:59:21 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18090395 | | | 10/5/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE COOLING AND HEATING CALCULATIONS FOR THE NEW | | | DUCTLESS AC SYSTEM- SECTION C403.2.1 FBC-17 ENERGY | | | CONSERVATION. | | | | | | 2) M-1: PROVIDE A CHECK VALVE ON THE CONDENSATE LINE OF | | | THE FAN COIL UNIT- SECTION 307.2.4.1 FBC M. | | | | | | 3) M-1: INDICATE THE SIZE AND METAL GAUGE OF THE | | | CONDENSER STRAPS SHOWN IN THE MOUNTING DETAIL- SECTION | | | 107.2.1 WPB. | | | | | | 4) M-1: INDICATE HOW THE CU WILL PROTECTED AGAINST | | | VEHICULAR IMPACT- SECTION 303.4 FBC M. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
|