Plan Review Details - Permit 18090384
| Plan Review Stops For Permit 18090384 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-09-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-22 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-22 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2018-09-22 13:04:25 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FS553, THIS WAS ISSUED AS AN INTERIOR DEMOLITION | | | PERMIT, ISSUED TO A GENERAL CONTRACTOR. THE GC MAY | | | EXPAND THE SCOPE TO INCLUDE INTERIOR RENOVATION, BUT A | | | NEW PERMIT APPLICATION SIGNED BY OWNER AND CONTRACTOR | | | IS REQUIRED. | | | | | | IT APPEARS THAT WORK PROPOSED IS ELECTRICAL ONLY. IF GC | | | DOES NOT AGREE TO EXPAND THE SCOPE OF HIS PERMIT TO | | | INCLUDE THIS ELECTRICAL WORK, THERE ARE TWO OPTIONS: | | | | | | CLOSE OUT THE ISSUED INTERIOR DEMO PERMIT (FINAL | | | INSPECTIONS), THEN APPLY FOR A NEW ELECTRICAL PERMIT, | | | OR | | | PROVIDE A LETTER SIGNED BY GC, OWNER AND ELECTRICAL | | | CONTRACTOR STATING THAT ALL WILL WORK TOGETHER TOWARDS | | | CODE COMPLIANCE, AND THE ELECTRICAL CONTRACTOR CAN | | | OBTAIN A SEPARATE ELECTRICAL PERMIT. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-09-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-09-19 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-09-19 |
Time |
11:48 |
Sent To |
B |
|
| Notes |
| 2018-09-19 11:51:05 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | NEED TO SHOW LOCATION OF SERVICE AND PANELS IN/ON | | | BUILDING | | | | | | 480 VOLT PANEL SHOW RECEPTACLE LOAD???? | | | | | | PLEASE SUBMIT PANEL SHCEDULE FOR 208 PANEL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-09-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-22 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-11 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2018-09-13 11:16:28 | REVISION ROUTED TO JLEAHY |
|
|
|