Plan Review Details - Permit 18090383
Plan Review Stops For Permit 18090383
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-11-16 Cont ID  
Sent By shill Date 2018-11-16 Time 13:11 Rev Time 0.00
Received By shill Date 2018-11-16 Time 12:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-10-06 Cont ID  
Sent By shill Date 2018-10-06 Time 15:01 Rev Time 0.00
Received By shill Date 2018-10-06 Time 15:01 Sent To  
Notes
2018-10-06 15:01:59****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. ADDRESS PLUMBING ACCESSIBILITY COMMENTS WHICH ARE
 APPLICABLE FOR BUILDING REVIEW.
  
 2. EXISTING DOOR TO OFFICE 108, REVISE PLAN TO INDICATE
 THAT IT DOES NOT HAVE A CLOSER AND A LATCH, FBC A
 FIGURE 404.2.4.1(C). IF IT DOES HAVE A CLOSER AND A
 LATCH, PLEASE CONTACT ME PRIOR TO RESUBMITTING.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-10-30 Cont ID  
Sent By jpearson Date 2018-10-30 Time 15:54 Rev Time 0.00
Received By jpearson Date 2018-10-30 Time 15:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-09-22 Cont ID  
Sent By jpearson Date 2018-09-22 Time 15:01 Rev Time 0.00
Received By jpearson Date 2018-09-22 Time 15:01 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-10-29 Cont ID  
Sent By pleduc Date 2018-10-29 Time   Rev Time 0.00
Received By pleduc Date 2018-10-29 Time 14:07 Sent To I
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-09-21 Cont ID  
Sent By pleduc Date 2018-09-21 Time   Rev Time 0.00
Received By pleduc Date 2018-09-20 Time 15:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-11-16 Cont ID  
Sent By shill Date 2018-11-16 Time 13:11 Rev Time 0.00
Received By shill Date 2018-10-24 Time 15:56 Sent To  
Notes
2018-10-25 15:57:06B18

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-10-06 Cont ID  
Sent By shill Date 2018-10-06 Time 15:02 Rev Time 0.00
Received By shill Date 2018-09-11 Time 11:26 Sent To  
Notes
2018-09-13 11:26:46B15

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-11-08 Cont ID  
Sent By ccole Date 2018-11-08 Time 08:31 Rev Time 0.00
Received By ccole Date 2018-11-08 Time 07:31 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2018-09-24 Cont ID  
Sent By ccole Date 2018-09-24 Time 12:19 Rev Time 0.00
Received By ccole Date 2018-09-24 Time 12:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2018-11-13 Cont ID  
Sent By gjohnson Date 2018-11-13 Time 10:21 Rev Time 0.00
Received By gjohnson Date 2018-11-13 Time 10:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-10-02 Cont ID  
Sent By gjohnson Date 2018-10-02 Time 09:08 Rev Time 0.00
Received By gjohnson Date 2018-10-01 Time 15:21 Sent To  
Notes
2018-10-02 09:46:411ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. PLEASE SHOW COMPLIANCE WITH FBC ACC 608.3.1 TRANSFER
 TYPE SHOWER COMPARTMENTS.
 IN TRANSFER TYPE COMPARTMENTS, GRAB BARS SHALL BE
 PROVIDED ACROSS THE CONTROL WALL AND BACK WALL TO A
 POINT 18 INCHES FROM THE CONTROL WALL.
  
 2. PLEASE SHOW COMPLIANCE WITH FBC ACC 608.4 SEATS. A
 FOLDING OR NON-FOLDING SEAT SHALL BE PROVIDED IN
 TRANSFER TYPE SHOWER COMPARTMENTS.
 610.3 IN TRANSFER-TYPE SHOWERS, THE SEAT SHALL EXTEND
 FROM THE BACK WALL TO A POINT WITHIN 3 INCHES OF THE
 COMPARTMENT ENTRY. THE TOP OF THE SEAT SHALL BE 17
 INCHES MINIMUM AND 19 INCHES MAXIMUM ABOVE THE BATHROOM
 FINISH FLOOR. SEATS SHALL COMPLY WITH 610.3.1 OR
 610.3.2.
  
 3. PLEASE SHOW COMPLIANCE WITH FBC ACC 608.5.1 TRANSFER
 TYPE SHOWER COMPARTMENTS.
 IN TRANSFER TYPE SHOWER COMPARTMENTS, THE CONTROLS,
 FAUCETS, AND SHOWER SPRAY UNIT SHALL BE INSTALLED ON
 THE SIDE WALL OPPOSITE THE SEAT 38 INCHES (965 MM)
 MINIMUM AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE
 SHOWER FLOOR AND SHALL BE LOCATED ON THE CONTROL WALL
 15 INCHES (380 MM) MAXIMUM FROM THE CENTERLINE OF THE
 SEAT TOWARD THE SHOWER OPENING.
  
 4. TEMPERED WATER SHALL BE REQUIRED TO BE DELIVERED
 FROM THE LAVATORY. TEMPERED WATER SHALL BE DELIVERED
 THROUGH AN APPROVED WATER-TEMPERATURE LIMITING DEVICE
 THAT CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL
 416.5
  
 5. THE REFRIGERATOR ICE MACHINE IS NOT SHOWN ON THE
 WATER ISOMETRIC. PLEASE CLARIFY. PER WPB AMEND TO FBC
 107.2.1
  
 6. A BACKFLOW IS REQUIRED ON THE SUPPLY TO THE ICE
 MACHINE. PER FBC PL 608.3
  
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  