| Plan Review Stops For Permit 18090371 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2018-12-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-17 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-17 |
Time |
09:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2018-12-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-13 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-12 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2018-12-13 08:17:13 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 4TH REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. DEMO PLAN SHEET MISSING FROM 2ND SET OF PLANS. | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | | APPLICATION. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-12-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-05 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-05 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2018-12-05 14:04:51 | THIS RE-SUBMITTAL NEEDS TO GO THROUGH THE LIBRARIANS. | | | PLEASE ASSIGN BLDG. REVIEW TO SHILL. CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-12-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-05 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-12-05 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2018-12-05 12:06:18 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. VALUE CHANGED. OK | | | 2. NEW PLAN SHEETS TO BE SUBMITTED. | | 2018-11-01 10:30:28 | ELECTRICAL PLAN REVIEW COMMENTS FROM 9/21/18 EXPLAINED | | | THAT ALL SHEETS ARE REQUIRED TO BE SIGNED/SEALED BY THE | | | PERSON RESPONSIBLE FOR DESIGN. ON RE-SUBMISSION, ONLY | | | THE ELECTRICAL SHEETS HAVE BEEN CORRECTED. JP |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-10-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-06 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-06 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2018-10-06 14:48:03 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. ADDRESS PLUMBING COMMENTS, APPLICABLE FOR BUILDING | | | REVIEW (FBC ACCESSIBILITY). | | | | | | 2. FBC 109, VALUE IS TO INCLUDE ALL LABOR, MATERIALS, | | | OVERHEAD, PROFIT, INCLUDING ITEMS PROVIDED BY OTHERS. | | | PROVIDE A COST BREAKDOWN AND CONTRACT. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-11-01 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-11-01 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-11-01 |
Time |
10:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-09-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-09-21 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-09-21 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2018-09-21 12:59:31 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PER THE WPB AMENDMENTS TO THE FBC, PLAN (EACH SHEET | | | OF BOTH COPIES) IS REQUIRED TO BEAR THE NAME AND BE | | | SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE | | | DESIGN. THIS PERSON MUST BE A LICENSED DESIGN | | | PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. | | | PROVIDE CORRECTION. WPB FBC 107.1, 107.2; FS 471, 481 | | | 2. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. FBC 109.3 | | | 3. PROVIDE ACCURATE RISER DIAGRAM, SHOWING ALL DETAILS | | | OF SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | | INTERSYSTEM BONDING TERMINATION POINT. RISER PROVIDED | | | INDICATES THIS IS A 3 PHASE SERVICE, BUT PANEL | | | SCHEDULES INDICATE THIS IS A SINGLE PHASE SERVICE. | | | PROVIDE CLARIFICATION. NEC 215.5, 230, 250.50, 250.94, | | | 408.30; WPB FBC 107.2.1 | | | 4. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF | | | SERVICE IS ADEQUATE. LOAD CALCULATION PROVIDED IS NOT | | | CODE COMPLIANT. NEC 215.2, 220, 408.30 | | | 5. PROVIDE THE ADDITIONAL INTERIOR LIGHTING CONTROLS | | | STIPULATED IN THE FBC ENERGY CODE. MANY AREAS DO NOT | | | SHOW THE AUTOMATIC CONTROL REQUIRED. FBC EC C405.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-10-30 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-10-30 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-10-30 |
Time |
10:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-09-14 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-09-14 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-09-14 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-12-14 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-12-14 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-12-05 |
Time |
15:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-12-05 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-12-05 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-11-08 |
Time |
08:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-10-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-06 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-11 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
N |
Date |
2018-12-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-12-14 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-12-14 |
Time |
08:20 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2018-12-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-12-12 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-12-12 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2018-12-12 14:37:42 | 3RD REVIEW FBC-2017 MECHANICAL | | | PERMIT #18090371 | | | 12/12/18 | | | | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M1: SIGNATURE OF CONTRACTOR OR QUALIFIER ON | | | PLANS REQUIRED: SEE FLORIDA STATUTE 633.021, AND | | | SECTION 107.2.1 FBC. WPB AMENDMENTS TO THE FBC: ALL | | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN. | | | | | | 2) M1: IT IS ACKNOWLEDGED THAT THE PARTITIONS LEAVE A | | | 24" AIR SPACE FOR AIRFLOW, HOWEVER THE PLAN APPEARS TO | | | SHOW FLEX DUCT RELOCATED OR EXTENDED TO AREA OF THE NEW | | | ROOMS. PLEASE LABEL THE DUCTS ON THE PLAN AS NEW (N), | | | EXISTING (E), OR RELOCATED (RE). | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2018-11-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-11-08 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-11-08 |
Time |
08:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-10-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-10-03 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-10-03 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2018-10-03 09:27:14 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18090371 | | | 10/3/18 | | | | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE MECHANICAL ALTERATION PLANS SHOWING | | | ALL NECESSARY CHANGES TO THE EXISTING SYSTEMS TO | | | PROVIDE THE REQUIRED VENTILATION TO THE NEW OFFICES- | | | SEE TABLE 403.3.1.1 AND SECTION 601.6 FBC M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-12-14 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-12-14 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-12-14 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-12-03 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-12-03 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-12-03 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2018-12-03 11:21:46 | 1) A MINIMUM OF TWO DRINKING FOUNTAINS ARE REQUIRED AND | | | SHALL BE HANDICAPPED ACCESSIBLE PER 2017 FBC-PLUMBING | | | TABLE 403.1 & SEC. 410.3, FL. ACCESS. CODE SEC.211.1. | | | 2) WHERE ARE YOU GETTING THE PLUMBING FIXTURE RATIO | | | COUNT FROM ON SHT. P1? THE NUMBER OF PLUMBING FIXTURES | | | IS CORRECT BUT THE RATIOS ARE INCORRECT. COMPLY WITH | | | 2017 FBC-PLUMBING TABLE 403.1 FOR "M" OCCUPANCY. | | | 3) THE FLOOR PLAN LAYOUT AND NUMBER OF FIXTURES ON SHT. | | | A2 DOES NOT CORRELATE WITH SHT.A1 OR P1. SHT. A2 DOES | | | NOT SHOW THE DRINKING FOUNTAIN OR SERVICE SINK AND A | | | URINAL IS SHOWN IN THE MEN'S RESTROOM. SUBMIT A REVISED | | | SHT. A2 THAT CCORRELATES WITH THE OTHER SHEETS. | | | 4) SUBMIT A WATER RISER DIAGRAM FOR THE ADDED DRINKING | | | FOUNTAINS AND SERVICE SINK. WPB AMEND. TO FBC SEC. | | | 107.3.5.1.3. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | 2018-11-01 10:30:01 | ELECTRICAL PLAN REVIEW COMMENTS FROM 9/21/18 EXPLAINED | | | THAT ALL SHEETS ARE REQUIRED TO BE SIGNED/SEALED BY THE | | | PERSON RESPONSIBLE FOR DESIGN. ON RE-SUBMISSION, ONLY | | | THE ELECTRICAL SHEETS HAVE BEEN CORRECTED. JP |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-10-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-10-02 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-10-01 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2018-10-02 10:35:20 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. INDICATE ON THE TYPE OF OCCUPANCY, THE OCCUPANT LOAD | | | AND PROVIDE A PLUMBING FIXTURE COUNT BREAKDOWN IT SHALL | | | COMPLY WITH FBC PL SEC 403.1 AND TABLE 403.1 IT MAY BE | | | REQUIRED TO PROVIDE A WATER FOUNTAIN AND SERVICE SINK | | | DEPENDING ON OCCUPANT LOAD. | | | | | | 2. THE RECONFIGURED BATHROOMS SHALL COMPLY WITH FBC ACC | | | 2017 6TH EDITION SEC 213 | | | PLEASE SHOW COMPLIANCE WITH THE FOLLOWING | | | 604.2 LOCATION. THE WATER CLOSET SHALL BE POSITIONED | | | WITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE. | | | THE CENTERLINE OF THE WATER CLOSET SHALL BE 16 INCHES | | | MINIMUM TO 18 INCHES MAXIMUM FROM THE SIDE WALL OR | | | PARTITION | | | 604.3.1 SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE | | | 60 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE | | | WALL AND 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM | | | THE REAR WALL. | | | 604.4 SEATS. THE SEAT HEIGHT OF A WATER CLOSET ABOVE | | | THE FINISH FLOOR SHALL BE 17 INCHES MINIMUM AND 19 | | | INCHES MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS | | | SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. | | | 604.5.1 SIDE WALL. THE SIDE WALL GRAB BAR SHALL BE 42 | | | INCHES LONG MINIMUM, LOCATED 12 INCHES MAXIMUM FROM THE | | | REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE REAR | | | WALL. | | | 604.5.2 REAR WALL. THE REAR WALL GRAB BAR SHALL BE 36 | | | INCHES LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF | | | THE WATER CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 | | | INCHES MINIMUM ON THE OTHER SIDE. | | | 609.4 POSITION OF GRAB BARS. GRAB BARS SHALL BE | | | INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM | | | AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED | | | TO THE TOP OF THE GRIPPING SURFACE | | | 606.2 THE LAVATORY SHALL HAVE A CLEAR FLOOR SPACE. A | | | CLEAR FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR A | | | FORWARD APPROACH, AND KNEE AND TOE CLEARANCE COMPLYING | | | WITH 306 SHALL BE PROVIDED. | | | 606.3 HEIGHT. LAVATORIES AND SINKS SHALL BE INSTALLED | | | WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER | | | SURFACE 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR | | | GROUND. | | | | | | | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|