Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-10-06 Cont ID  
Sent By shill Date 2018-10-06 Time 15:36 Rev Time 0.00
Received By shill Date 2018-10-06 Time 15:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-11-27 Cont ID  
Sent By jleahy Date 2018-11-27 Time 10:46 Rev Time 0.00
Received By jleahy Date 2018-11-27 Time 10:46 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-10-02 Cont ID  
Sent By jleahy Date 2018-09-25 Time 07:22 Rev Time 0.00
Received By jleahy Date 2018-09-25 Time 07:22 Sent To  
Notes
2018-09-25 07:27:34FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PROVISIO
  
 SUBMIT THE FOLLOWING INFORMATION PRIOR TO THE FIANL
 ELECTRCAL INSPECTION.
  
 ADDED LOAD NEEDS TO BE CALCULATED INTO THE LOAD CALC
 FOR THIS UNIT. STEAM UNIT. PLAN SHOWS 100A TO STEAM
 UNIT PANEL SCHEDULE SHOWS 70A?
  
 TV ADDED IN THE BATH AREA 406.9(C) OUTLET NOT ALLOWED
 IN BATH OR SHOWER AREA.
  
 REVISION SHOWS NO ADDED VALUE? (STEAM UNIT)

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-12-06 Cont ID  
Sent By gjohnson Date 2018-12-06 Time 12:55 Rev Time 0.00
Received By gjohnson Date 2018-12-04 Time 08:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-12-03 Cont ID  
Sent By gjohnson Date 2018-12-03 Time 17:06 Rev Time 0.00
Received By gjohnson Date 2018-11-26 Time 10:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-10-10 Cont ID  
Sent By gjohnson Date 2018-10-10 Time 16:57 Rev Time 0.00
Received By gjohnson Date 2018-09-07 Time 10:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2018-12-06 Cont ID  
Sent By gjohnson Date 2018-12-06 Time 12:55 Rev Time 0.00
Received By gjohnson Date 2018-12-06 Time 12:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2018-12-03 Cont ID  
Sent By gjohnson Date 2018-12-03 Time 17:04 Rev Time 0.00
Received By gjohnson Date 2018-12-03 Time 17:04 Sent To  
Notes
2018-12-03 17:06:28SHT P2-90-14A HAS NOT BEEEN REVISED. AS OF 12/03/18/
 GPJ

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-10-10 Cont ID  
Sent By gjohnson Date 2018-10-10 Time 15:25 Rev Time 0.00
Received By gjohnson Date 2018-10-10 Time 15:25 Sent To  
Notes
2018-10-10 16:57:201ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. THE DISCHARGE FROM THE STEAM UNIT SHALL DISCHARGE
 THRU AN AIR GAP INTO A WASTE RECEPTOR NOT A FLOOR DRAIN
 . FBC PL 802.2 AND THE WASTE RECEPTOR CANNOT BE
 INSTALLED IN CONCEALED SPACES. WASTE RECEPTORS SHALL
 NOT BE INSTALLED IN PLENUMS, CRAWL SPACES, ATTICS,
 INTERSTITIAL SPACES ABOVE CEILINGS AND BELOW FLOORS.
 READY ACCESS SHALL BE PROVIDED TO WASTE RECEPTORS. THE
 WASTE RECEPTOR SHALL BE INSTALLED IN A CLOSET OR OPEN
 AREA PER FBC PL 802.3
  
 2. ON SHT P2-90-14A IT NOTES THAT THE STEAM UNIT IS BY
 OTHERS IF THIS IS CORRECT A SEPARATE PERMIT WILL BE
 REQUIRED. PLACE NOTE ON PLAN. PER WPB AMEND TO FBC
 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2018-10-06 Cont ID  
Sent By shill Date 2018-10-06 Time 15:32 Rev Time 0.00
Received By shill Date 2018-10-06 Time 15:32 Sent To  
Notes
***NONE***