Plan Review Details - Permit 18090126
| Plan Review Stops For Permit 18090126 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2018-09-19 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2018-09-19 |
Time |
|
Rev Time |
1.00 |
| Received By |
rrossano |
Date |
2018-09-18 |
Time |
|
Sent To |
I |
|
| Notes |
| 2018-09-19 11:26:23 | PASSED WITH PROVISO: | | | PROVIDE CLEANOUT INSIDE PROPERTY LINE. SEE WPB GRAVITY | | | STANDARD DETAIL SHEET GS-6, HERE: HTTP://WPB.ORG/DEPART | | | MENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATI | | | ONS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-10-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-10-01 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-09-27 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2018-09-28 14:27:52 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-09-19 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2018-09-19 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2018-09-05 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2018-09-06 16:31:20 | PLUMB <5K |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-10-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-10-01 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-10-01 |
Time |
11:38 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-09-14 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2018-09-14 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2018-09-14 |
Time |
08:54 |
Sent To |
ENG |
|
| Notes |
| 2018-09-14 09:14:00 | 1) SUBMIT FACTORY SIZING CALCULATIONS FROM SCHIER FOR | | | THE INTERCEPTOR. THE SIZING CALCULATIONS ON THE PLANS | | | ARE VAGUE.2017 FBC- PLUMBING SEC. 1003.2. | | | 2) A SAMPLING PORT IS REQUIRED ON THE DISCHARGE SIDE OF | | | THE GREASE INTERCEPTOR. A 4 INCH TWO WAY CLEANOUT WILL | | | SUFFICE. ALTHOUGH IT IS IN THE NOTES ON THE PLANS, | | | PLEASE SHOW THE CLEANOUTS ON THE INLET AND OUTLET LINES | | | ON THE GREASE INTERCEPTOR. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
|