Plan Review Details - Permit 18090063
| Plan Review Stops For Permit 18090063 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-10-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-10-06 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-06 |
Time |
11:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-09-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-15 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-15 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2018-09-15 11:34:30 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. DEMOLITION OF WINDOWS AND DOORS IS NOT ALLOWED TO BE | | | INCLUDED IN THE SCOPE OF A DEMO PERMIT AS IT IS A VERY | | | SIMPLE PROCESS TO OBTAIN A WINDOW/DOOR PERMIT. REMOVE | | | THESE ITEMS FROM THE SCOPE OF THIS PERMIT - THE PLAN | | | SUBMITTED CAN BE MARKED UP BY HAND IF DESIRED RATHER | | | THAN HAVING THE CHANGES DONE BY THE ARCHITECT. | | | | | | 2. FBC 109, VALUE TOO LOW. | | | | | | 3. CLARIFY SCOPE. PLAN SHOWS DEMOLITION OF A ROOFED | | | PATIO, BUT THE PERMIT DESCRIPTION IN OUR SOFTWARE IS | | | "INTERIOR DEMOLITION AS PER PLAN" AND THE PERMIT TYPE | | | IS INTERIOR DEMO, BUT THE PERMIT APPLICATION STATES | | | THIS IS "DEMOLITION". AFTER SCOPE IS DETERMINED, | | | ADDITIONAL REVIEWS MAY BE REQUIRED. | | | | | | 4. AN ELECTRIC SUB PERMIT IS REQUIRED FOR ALL INTERIOR | | | DEMO PERMITS UNLESS PLAN CLEARLY SHOWS THAT ELECTRIC IS | | | ENTIRELY UNAFFECTED. WHEN RESUBMITTING, SUBMIT | | | ELECTRICAL SUB PERMIT IF NEEDED. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2018-10-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-10-09 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-10-09 |
Time |
08:04 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-10-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-10-09 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-09-26 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2018-10-06 11:15:48 | 10/6 TO JL DESK | | | | | 2018-09-28 09:55:29 | RESUB ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-09-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-15 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-04 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2018-09-06 10:07:24 | ROUTED TO SHILL |
|
|
|