Plan Review Details - Permit 18081585
| Plan Review Stops For Permit 18081585 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2019-04-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-03 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-04-03 |
Time |
16:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-02-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-02-26 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-02-26 |
Time |
07:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-11-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-11-08 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-11-08 |
Time |
08:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-11-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-11-02 |
Time |
21:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-11-02 |
Time |
21:41 |
Sent To |
|
|
| Notes |
| 2018-11-02 21:43:05 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC B 1609, ON THE PRODUCT APPROVALS, INDICATE WHICH | | | OPTION IS PROPOSED TO SHOW COMPLIANCE WITH DESIGN | | | PRESSURES SPECIFIED. | | | | | | 2ND REVIEW, RESPONSE LETTER STATES THAT THIS WILL BE | | | PROVIDED BY CONTRACTOR, NOT PROVIDED. | | | | | | 2. OK | | | | | | 3. FOR THE FLOORING UNDERLAYMENT, PROVIDE THE FOLLOWING | | | TEST REPORTS. IT IS RECOMMENDED THAT THIS BE RESOLVED | | | VIA EMAIL PRIOR TO RESUBMITTAL. EMAIL THE NAME OF THE | | | UNDERLAYMENT PROPOSED TO [email protected] WITH THE PERMIT | | | NUMBER IN THE SUBJECT LINE. IF THE MANUFACTURER HAS | | | ALREADY PROVIDED THE REQUIRED TEST REPORTS DIRECTLY TO | | | US, TEST REPORTS DO NOT NEED TO BE SUBMITTED WHEN | | | RESUBMITTING. | | | | | | PLEASE NOTE THAT TEST REPORTS ARE REQUIRED - | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | 2ND REVIEW, A LINK TO NAC SUPERSAM 125 WAS PROVIDED VIA | | | EMAIL. NO TEST REPORTS WERE PROVIDED. DO NOT SEND | | | LINKS; ONLY SEND PDFS IF YOU WOULD LIKE A COURTESY | | | REVIEW VIA EMAIL. OUR IT DEPARTMENT DISCOURAGES OPENING | | | OF LINKS; THIS WILL NOT BE DONE IN THE FUTURE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-09-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-25 |
Time |
17:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-09-25 |
Time |
17:48 |
Sent To |
|
|
| Notes |
| 2018-09-25 17:52:25 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC B 1609, ON THE PRODUCT APPROVALS, INDICATE WHICH | | | OPTION IS PROPOSED TO SHOW COMPLIANCE WITH DESIGN | | | PRESSURES SPECIFIED. | | | | | | 2. FBC 107, PRODUCT APPROVALS ARE TO BE REVIEWED BY | | | DESIGNER OF RECORD (SHOP DRAWING REVIEW OR LETTER OR | | | INCORPORATE INTO PLAN). | | | | | | 2. PLEASE ADVISE, WHAT TYPE OF FLOORING IS PROPOSED? | | | SEE ITEM 4. | | | | | | 3. FOR THE FLOORING UNDERLAYMENT, PROVIDE THE FOLLOWING | | | TEST REPORTS. IT IS RECOMMENDED THAT THIS BE RESOLVED | | | VIA EMAIL PRIOR TO RESUBMITTAL. EMAIL THE NAME OF THE | | | UNDERLAYMENT PROPOSED TO [email protected] WITH THE PERMIT | | | NUMBER IN THE SUBJECT LINE. IF THE MANUFACTURER HAS | | | ALREADY PROVIDED THE REQUIRED TEST REPORTS DIRECTLY TO | | | US, TEST REPORTS DO NOT NEED TO BE SUBMITTED WHEN | | | RESUBMITTING. | | | | | | PLEASE NOTE THAT TEST REPORTS ARE REQUIRED - | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-10-19 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-10-19 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-10-19 |
Time |
06:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-09-17 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-09-17 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-09-17 |
Time |
12:05 |
Sent To |
|
|
| Notes |
| 2018-09-17 16:03:22 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. NOTE 9 AND PANEL SCHEDULES SHOWN ARE NOT CODE | | | COMPLIANT IN REFERENCE TO AFCI PROTECTION. ALL BRANCH | | | CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- AND | | | 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY ROOMS, | | | DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, | | | BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | | 210.8, 210.12 | | | 2. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC 210.8(D) | | | 3. POWER PLAN SHOWS 3 PANELS, PANEL A, PANEL B, AND | | | PANEL L. RISER DIAGRAM ONLY SHOWS 2 PANELS, AND ONLY 2 | | | PANEL SCHEDULES ARE PROVIDED. PROVIDE CLARIFICAITON | | | AND/OR CORRECTION. NEC 215.5; WPB FBC 107.2.1 | | | 4. LIGHTING IN SHOWER/TUB AREAS IS SHOWN AS STANDARD | | | RECESS LIGHTS. LIGHTING IN BATHTUB OR SHOWER AREAS | | | SHALL BE SUITABLE FOR DAMP LOCATIONS. NO PARTS OF | | | CORD-CONNECTED LUMINAIRES, CHAIN-, CABLE-, OR | | | CORD-SUSPENDED LUMINAIRES, LIGHTING TRACK, PENDANTS, OR | | | CEILING-SUSPENDED (PADDLE) FANS SHALL BE LOCATED WITHIN | | | A ZONE MEASURED 3 FEET HORIZONTALLY AND 8 FEET | | | VERTICALLY FROM THE TOP OF THE BATHTUB RIM OR SHOWER | | | STALL THRESHOLD. PROVIDE CORRECTION. NEC 410.10(D) | | | 5. LIGHTING IN CLOSETS IS SHOWN AS STANDARD RECESS | | | LIGHTS. LIGHTING WITH OPEN OR PARTIALLY ENCLOSED LAMPS | | | AND PENDANT LUMINAIRES OR LAMPHOLDERS SHALL NOT BE | | | PERMITTED IN CLOTHES CLOSETS. PROVIDE CORRECTION. NEC | | | 410.16 | | | 6. IT APPEARS THAT A GFCI RECEPTACLE IS SHOWN WITHIN | | | THE TUB/SHOWER AREA OF THE MASTER BATH. RECEPTACLES | | | SHALL NOT BE INSTALLED WITHIN A TUB OR SHOWER SPACE. | | | PROVIDE CLARIFICATION AND/OR CORRECTION. NEC 406.9(C) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-10-17 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-10-17 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-10-17 |
Time |
10:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-09-05 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-09-05 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-09-05 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2018-09-05 11:51:15 | PERMIT # 18081585 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | | | | 1) PROVIDE DRAWING NOTE INDICATING, ?FIRE PROTECTION | | | SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND | | | RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION | | | SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A | | | 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A | | | FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED | | | BY EMAIL ([email protected]) OR IN WRITING (FAX: | | | 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE | | | MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.? | | | | | | 2) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | | | SUE ELLEN CALDERON | | | ASSISTANT FIRE MARSHAL | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-04-03 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-04-03 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-03-25 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2019-03-26 15:51:45 | RESUB ROUTED TO GJOHNSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-02-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-02-26 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-02-12 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-11-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-11-06 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-10-11 |
Time |
15:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-09-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-25 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-31 |
Time |
15:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-02-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-02-15 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-02-15 |
Time |
12:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-10-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-10-24 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-10-24 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2018-10-24 12:42:04 | 2ND REVIEW FBC-2017 MECHANICAL | | | PERMIT #18081585 | | | 10/24/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) AC CALCULATIONS: THE CALCULATIONS DO NOT SHOW ANY | | | INTERNAL HEAT GAIN LOADS- SEE PAGE 1 AND REFER TO | | | SECTION C403.2.1 FBC M. | | | | | | 2) SHEET M201: A DUCT SMOKE DETECTOR IS REQUIRED IN THE | | | SUPPLY SYSTEM OF WSHP 1-01 PER SECTION 606.2.1 FBC M. | | | PLEASE NOTE THAT THE AIR DISTRIBUTION PLAN INDICATES | | | SUPPLY AIR OVER 2000 CFMS, AND IT IS THE POLICY OF THE | | | BUILDING DEPARTMENT TO REQUIRE DUCT SMOKE DETECTORS ON | | | 5-TON SYSTEMS UNLESS MANUFACTURER'S DATA VERIFIES THE | | | SYSTEMS CANNOT PRODUCE OVER 2000 CFMS. | | | | | | 3) M201: IT APPEARS THAT AN ADDITIONAL EXHAUST FAN WILL | | | BE REQUIRED IN THE BATHUB/SHOWER ROOM OF BATHROOM #3 | | | (BEDROOM #3 ON THE PLAN) IF THE WALLS OF THE ROOM ARE | | | NOT OPEN AT THE TOP. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-09-18 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-09-18 |
Time |
08:33 |
Sent To |
|
|
| Notes |
| 2018-09-18 08:53:30 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18081585 | | | 9/18/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017 | | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE CORRECT THE ADDRESS ON THE PERMIT | | | APPLICATION, THE PLANS AND THE CALCULATIONS. THE | | | CORRECT ADDRESS IS 529 S. FLAGLER DRIVE. | | | | | | 2) REFER TO SECTION R101.5.1.2 FBC EC. THE PROJECT | | | SHALL BE IN COMPLIANCE WITH THE COMMERCIAL PROVISIONS | | | OF THE FBC EC. REFER TO SECTIONS C101.5 AND C403.2.1 | | | AND SUBMIT REVISED ENERGY AND AC CALCULATIONS. | | | | | | 3) SHEET M201: UNDERSIZED BEDROOM RETURN SYSTEMS: A) | | | MASTER BEDROOM & BERDOOM #1- RETURN DUCTS SHALL BE | | | SIZED 1.5 TIMES THE CROSS SECTIONAL AREA OF THE SUPPLY | | | DUCT ENTERING THE ROOM. B) BEDROOMS 2 & 3: THE TRANSFER | | | GRILLS SHALL BE SIZED AT 50 SQUARE INCHES PER 100 CFMS | | | OF SUPPLY AIR- SECTION 601.6 FBC M. | | | | | | 4) M201: THE PLAN SHOWS DRYER EXHAUST AND TOILET | | | EXHAUST DUCTS CONNECTING INTO THE SAME SHAFT, HOWEVER A | | | COMMON MULTI-STORY DRYER EXHAUST SYSTEM SHALL SERVE | | | ONLY CLOTHES DRYERS. REFER TO SECTION 504.10 ITEMS 1-12 | | | AND PROVIDE ADDITIONAL DETAILS AND NOTES TO CLARIFY. | | | | | | 5) M201: THE PLAN SHOWS KITCHEN HOOD EXHAUST AND TOILET | | | EXHAUST DUCTS CONNECTING INTO THE SAME SHAFT, HOWEVER A | | | COMMON MULTI-STORY HOOD EXHAUST SYSTEM SHALL SERVE ONLY | | | KITCHEN HOOD EXHAUST. REFER TO SECTION 505.3 ITEMS 1-12 | | | AND PROVIDE ADDITIONAL DETAILS AND NOTES TO CLARIFY. | | | | | | 6) M201: VERIFY THAT ALL MATERIALS IN AC CLOSETS USED | | | AS PLENUM RETURNS ARE NON-COMBUSTIBLE OR ARE LISTED AND | | | LABELED AS HAVING A FLAME SPREAD OF NOT MORE THAN 25 | | | AND A SMOKE-DEVELOPED INDEX OF NOT MORE THN 50- SECTION | | | 602.2.1 FBC M. | | | | | | 7) PLEASE SUBMIT PRODUCT DATA SHEETS FOR ALL COOKING | | | APPLIANCES, KITCHEN HOOD, AND DRYER. ALL SUBMITTALS | | | SHALL BE APPROVED BY THE EOR. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | HTTPS://WWW.SURVEYMONKEY.COM/R/WESTPALMBEACHCONSTRUCTIO | | | NSERVICES | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2019-04-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-04-02 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-04-02 |
Time |
08:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2019-02-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-02-20 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-02-20 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2019-02-20 09:30:31 | 3RD REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: PREVIOUS COMMENTS NOT COMPLIED 2ND | | | REQUEST | | | | | | 3. DETAILS ON SHT. P101 THAT ARE NOT UNDER THE SCOPE OF | | | THIS PERMIT PLEASE REMOVE IF NOT BEING USED. IF WORK IS | | | BEING DONE ON THE ROOF DRAINS OR CONDENSATE PLEASE | | | PROVIDE PIPING DETAILS AND FLOOR PLANS SHOWING NEW WORK | | | . PER WPB AMEND TO FBC 107..2.1 | | | | | | 4. PROVIDE MANUFACTURE SPECIFICATIONS AND INSTALLATION | | | GUIDE FOR THE TUB DRAINS INSTALLED IN THE SHOWER STALLS | | | SHOW DETAIL OF HOW THE SHOWER PAN WILL BE SEALED AROUND | | | TUB DRAIN, THE MANUFACTURE SPECIFICATIONS SHALL ALSO | | | SHOW APPROVAL OF USE IN THIS APPLICATION. PER WPB AMEND | | | TO FBC 107..2.1 | | | | | | NEW COMMENTS: | | | | | | 1. SHT A-3 DETAIL #10 THE WATER PROOF MEMBRANE SHALL | | | PITCH TO DRAIN. PER FBC PL 417.5.2 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-11-05 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-11-05 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-11-05 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2018-11-05 17:18:19 | 3RD REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: PREVIOUS COMMENTS NOT COMPLIED 2ND | | | REQUEST | | | | | | 3. DETAILS ON SHT. P101 THAT ARE NOT UNDER THE SCOPE OF | | | THIS PERMIT PLEASE REMOVE IF NOT BEING USED. IF WORK IS | | | BEING DONE ON THE ROOF DRAINS OR CONDENSATE PLEASE | | | PROVIDE PIPING DETAILS AND FLOOR PLANS SHOWING NEW WORK | | | . PER WPB AMEND TO FBC 107..2.1 | | | | | | 4. PROVIDE MANUFACTURE SPECIFICATIONS AND INSTALLATION | | | GUIDE FOR THE TUB DRAINS INSTALLED IN THE SHOWER STALLS | | | SHOW DETAIL OF HOW THE SHOWER PAN WILL BE SEALED AROUND | | | TUB DRAIN, THE MANUFACTURE SPECIFICATIONS SHALL ALSO | | | SHOW APPROVAL OF USE IN THIS APPLICATION. PER WPB AMEND | | | TO FBC 107..2.1 | | | | | | NEW COMMENTS: | | | | | | 1. SHT A-3 DETAIL #10 THE WATER PROOF MEMBRANE SHALL | | | PITCH TO DRAIN. PER FBC PL 417.5.2 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-09-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-09-25 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2018-09-25 |
Time |
17:22 |
Sent To |
|
|
| Notes |
| 2018-09-25 17:44:29 | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 1ST REVIEW: | | | PERMIT 18081585 | | | PLUMBING COMMENTS: DENIED | | | | | | 1. PROVIDE PIPING MATERIALS TYPE & FIRE RATED | | | ASSEMBLIES FOR RELOCATED DRAIN FLOORPENETRATIONS WPB | | | FBC 107.2.1. | | | | | | 2. PROVIDE DETAIL FOR MASTER BATH & SHOWER MEMBRANE AS | | | APPLIED TO TEMPERED GLASS WALL, SEAT & THRESHOLD, FBC | | | 107.2.1. | | | | | | 3. SHOW CURB DETAIL ON TYPICAL SHOWER PAN DETAIL 11 | | | PLAN A3, FBC 107.2.1. | | | | | | 4. LAUNDRY - ADD NOTE AT STACKED WASHER/DRYER | | | "ACCESSIBLE SHUTOFF VALVES REQUIRED" FBC P 606.3. | | | | | | 5. SHEET P101 GENERAL PIPING NOTES MAKE REFERENCE TO | | | GAS PIPING BUT NONE IS SHOWN. IF NO GAS PIPING IS | | | PROPOSED, REMOVE THE NOTE. IF THERE IS GAS PIPING, THEN | | | A SEPARATE WILL BE REQUIRED, FBC 107.2.1. | | | | | | 6. KITCHEN SINK IS RLEOCATED REQUIRING LOCATION OF | | | STACK. PROVIDE A RISER DIAGRAM, FBC 107.3.5.1.3(13) | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL: [email protected] | | | 561-805-6715 | | | |
|
|
|