Plan Review Details - Permit 18081546
| Plan Review Stops For Permit 18081546 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2018-09-13 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-09-13 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-09-13 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-09-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-09-05 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-09-05 |
Time |
10:37 |
Sent To |
I |
|
| Notes |
| 2018-09-05 10:37:34 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. LOAD SUMMARY STATES THAT THE MAIN IS 600 AMPS, BUT | | | RISER SHOWS A 400 AMP MAIN. CORRECT DISCREPANCY. WPB | | | FBC 107.2.1 | | | 2. IF THE 400 AMP MAIN IS CORRECT, B PHASE AS SHOWN IS | | | OVERLOADED AT 413 AMPS. PROVIDE CORRECTION. NEC 215.2, | | | 408.30. | | | 3. NEW RISER DIAGRAM SHOWS PANEL A AND PANEL B BEING | | | FED FROM PANEL M, BUT THE LOAD FOR THESE PANELS IS NOT | | | INCLUDED IN PANEL M LOAD TOTALS. PROVIDE CORRECTION. | | | NEC 220, 408.4, 408.30; WPB FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | | SHEETS?. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-09-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-09-13 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-09-13 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2018-09-07 14:36:42 | REVISION ROUTED TO JPEARSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-09-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-08-31 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2018-09-04 13:53:25 | REVISION ROUTED TO JPEARSON |
|
|
|