| Plan Review Stops For Permit 18081512 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-02-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-02-27 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-02-27 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-02-16 |
|
|
Cont ID |
|
| Sent By |
jduprey |
Date |
2019-02-16 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-02-16 |
Time |
12:29 |
Sent To |
|
|
| Notes |
| 2019-02-16 12:33:11 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1.PROVISO: GENERATOR ATTACHMENT IS DELEGATED | | | ENGINEERING PER SEOR. THIS IS REQUIRED TO BE SUBMITTED | | | AS A REVISION, AND REVIEWED, PRIOR TO FIRST INSPECTION. | | | DELEGATED ENGINEERING TO BE REVIEWED BY SEOR PRIOR TO | | | SUBMITTAL TO THE CITY. | | | | | | 2. FBC 1609.1, SHEET S002 1060 2.3 DECLARES EXPOSURE C; | | | PLEASE PROVIDE JUSTIFICATION FOR C RATHER THAN D IN THE | | | RESPONSE LETTER. | | | | | | 3RD REVIEW; THIS WAS REVIEWED PRELIMINARILY VIA EMAIL. | | | A REQUEST WAS MADE FOR ENGINEER TO EVALUATE THE | | | CONDITION TO THE SOUTHEAST. ONLY THE NORTHEAST WAS | | | ADDRESSED. | | | | | | THIS MAY BE SENT VIA EMAIL IN A DIGITALLY SIGNED | | | LETTER. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-12-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-27 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-27 |
Time |
18:35 |
Sent To |
|
|
| Notes |
| 2018-12-27 18:36:05 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. PREVIOUS COMMENT LIST REQUESTED GENERATOR ATTACHMENT | | | DETAILS. DETAIL 5 ON SHEET S201 REFERS TO SPACING PER | | | MANUFACTURER SPECS. MANUFACTURER SPECS WERE NOT | | | PROVIDED. | | | | | | PLEASE NOTE THAT IF THE MANUFACTURER SPECS ARE USED TO | | | SHOW RESISTANCE TO WIND LOADS, THEY ARE TO BE PREPARED | | | BY A FLORIDA PE AND BE SIGNED AND SEALED. THIS WOULD BE | | | CONSIDERED DELEGATED ENGINEERING AND AS SUCH SHOULD BE | | | REVIEWED BY SEOR PRIOR TO SUBMITTAL. THE DELEGATED | | | ENGINEERING SHOULD INCLUDE THE SEOR'S WIND DESIGN | | | CRITERIA SO COMPLIANCE IS CLEAR. | | | | | | 2. FBC 1609.1, SHEET S002 1060 2.3 DECLARES EXPOSURE C; | | | PLEASE PROVIDE JUSTIFICATION FOR C RATHER THAN D IN THE | | | RESPONSE LETTER. | | | | | | 3. SHEET S002 REFERS TO AN OUTDATED CODE, 1060 ITEM 1 | | | (FBC 2014). REVISE AND CHECK ALL. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-10-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-10-04 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-10-04 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2018-10-04 14:03:39 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. NOA FOR STEEL DOOR TO BE REVIEWED BY DESIGNER OF | | | RECORD. | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE DOOR SUBMITTALS. | | | | | | 2. ELECTRICAL SUB-PERMIT REQUIRED. | | | | | | 3. PROVIDE THE MANUFACTURERS INSTALLATION INSTRUCTIONS | | | THE PROPOSED GENERATORS. DETAIL OF GENERATOR TO | | | FOUNDATION REQUIRED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2019-03-04 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-03-04 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-03-04 |
Time |
07:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2019-02-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2019-02-01 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2019-02-01 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2019-02-01 11:58:36 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PLEASE INDICATE THE TOTAL VALUE FOR THE WORK INVOLVED. | | | | | | PLEASE SUBMIT A CONTRACT SIGNED BY THE "CUSTOMER" NOT | | | THE MANUFACTURER AND CONTRACTOR. | | | | | | $585,000 WOULD SEEM TO COVER THE GENERATORS AND | | | ENCLOSURES BUT NOT THE REMAINDER OF THE WORK, SITE | | | WORK, ELECTRICAL SWITCH GEAR, CONDUCTORS, ECT, ECT. | | | | | | 109.3BUILDING PERMIT VALUATIONS. | | | THE APPLICANT FOR A PERMIT SHALL PROVIDE AN ESTIMATED | | | PERMIT VALUE AT TIME OF APPLICATION. PERMIT VALUATIONS | | | SHALL INCLUDE TOTAL VALUE OF WORK, INCLUDING MATERIALS | | | AND LABOR, FOR WHICH THE PERMIT IS BEING ISSUED, SUCH | | | AS ELECTRICAL, GAS, MECHANICAL, PLUMBING EQUIPMENT AND | | | PERMANENT SYSTEMS. IF, IN THE OPINION OF THE BUILDING | | | OFFICIAL, THE VALUATION IS UNDERESTIMATED ON THE | | | APPLICATION, THE PERMIT SHALL BE DENIED, UNLESS THE | | | APPLICANT CAN SHOW DETAILED ESTIMATES TO MEET THE | | | APPROVAL OF THE BUILDING OFFICIAL. FINAL BUILDING | | | PERMIT VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-12-04 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-12-04 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-12-04 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2018-12-04 11:26:42 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | VALUE FOR THE JOB STILL NEEDS TO RESOLVED, PLEASE | | | SUBMIT SIGNED COPY OF THE CONTRACT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-09-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-09-26 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-09-26 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2018-09-26 12:42:13 | FLORIDA BUILDING CODE 2017 6TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | | NFPA 70 2014 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PERMIT CAN NOT BE ISSUED TO A CGC WITHOUT AN ELECTRICAL | | | SUB-PERMIT | | | | | | #1 | | | GSB HAS 1600A BREAKER | | | ATS-2 HAS A 3000A BREAKER | | | | | | 240.87 ARC ENERGY REDUCTION | | | WHERE THE HIGHEST CONTINUOUS CURRENT TRIP SETTING FOR | | | WHICH THE | | | ACTUAL OVERCURRENT DEVICE INSTALLED IN A CIRCUIT | | | BREAKER IS RATED | | | OR CAN BE ADJUSTED IS 1200 A OR HIGHER, 240.87(A) AND | | | (B) SHALL | | | APPLY. | | | (A) DOCUMENTATION. DOCUMENTATION SHALL BE AVAILABLE TO | | | THOSE | | | AUTHORIZED TO DESIGN, INSTA LL, OPERATE, OR INSPECT THE | | | INSTALLATION | | | AS TO THE LOCATION OF THE CIRCUIT BREAKER(S). | | | | | | #2 | | | VALUE TO LOW FOR PROPOSED WORK. | | | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | | TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE | | | CONGRESS. FINAL BUILDING PERMIT VALUATION SHALL BE SET | | | BY THE BUILDING OFFICIAL. | | | | | | #3 | | | SUBMIT CUT SHEETS ON PANEL GSB, ATS #1, #2, MAIN LSI, | | | EMERGENCY MAIN. GENERATORS. | | | | | | #4 | | | 800A MAIN LSI IS NOT GROUPED WITH ATS-1 MAIN | | | 200A EMERGENCY MAIN IS NOT GROUPED WITH ATS-2 MAIN. | | | | | | #5 | | | 250.64 GROUNDING ELECTRODE CONDUCTOR INSTALLATION | | | (A) ALUMINUM OR CO PPER-CLAD ALUMINUM CONDUCTORS. | | | BARE ALUMINUM OR COPPER-CLAD ALUMINUM GROUNDING | | | ELECTRODE | | | CONDUCTORS SHALL NOT BE USED WHERE IN DIRECT CONTACT | | | WITH MASONRY | | | OR THE EARTH OR WHERE SUBJECT TO CORROSIVE CONDITIONS. | | | WHERE | | | USED OUTSIDE, ALUMINUM OR COPPER-CLAD ALUMINUM | | | GROUNDING | | | ELECTRODE CONDUCTORS SHALL NOT BE TERMINATED WITHIN 450 | | | MM | | | (18 IN.) OF THE EARTH. | | | | | | #6 | | | WIRE AND CONDUIT SCHEDULE #9 SHOWS A 2/0 WHICH SHOULD | | | BE 4/0 | | | | | | #7 | | | PROVIDE FPL MAXIMUM DEMAND FOR THE SERVICE RECORDS FOR | | | THE MAINS LOAD CALCULATION. | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-11-26 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-11-26 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-11-26 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-09-18 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-09-18 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-09-18 |
Time |
12:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2019-02-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-02-19 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-02-19 |
Time |
08:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-12-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-12-28 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-12-28 |
Time |
12:18 |
Sent To |
|
|
| Notes |
| 2018-12-28 12:30:37 | 2ND REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PREVIOUS GAS COMMENTS: NOT COMPLIED 2ND REQUEST. | | | | | | 1. PROVIDE MANUFACTURE SPECIFICATION AND INSTALLATION | | | GUIDES FOR GENERATOR, REGULATORS, SUCTION AND RETURN | | | PUMPS, THE DUAL WALL PIPING WITH LEAK DETECTION, | | | GEOFLEX PIPING, AND ANY NEW EQUIPMENT ON THE FUEL TANK | | | SUCH AS THE ANTI SIPHON VALVE AND FOOT VALVE. PER WPB | | | AMEND TO FBC 107.2.1 | | | IN THE RESPONSE LETTER IT STATED THAT MANUFACTURE SPEC | | | WILL BE SUPPLIED IN SUBMITTAL PHASE THIS REVIEW IS | | | CONSIDERED THE SUBMITTAL PHASE AND IT WILL BE REQUIRED | | | TO SUBMIT THE DOCUMENTATION TO VERIFY CODE COMPLIANCE. | | | | | | 2. COMPLIED | | | | | | 3. ON THE NATURAL GAS RISER PLEASE SHOW THE FOLLOWING: | | | A) COMPLIED | | | B) COMPLIED | | | C) COMPLIED | | | D) SHOW DISTANCE AND SIZE OF PIPE FROM REGULATOR TO THE | | | GENERATOR. | | | E) COMPLIED | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 4. COMPLIED | | | | | | 5. COMPLIED | | | | | | NEW COMMENT: | | | | | | 1. THE FIRST SECTION OF PIPE AFTER THE METER SHALL BE | | | 3" TO SUPPLY THE EXISTING LOAD AND THE NEW LOAD | | | COMBINED. PER FBC FG TABLE 402.4(5) | | | | | | 2. PLEASE PLACE NOTE ON PLAN. CITY OF WEST PALM BEACH | | | GAS PIPING AFFIDAVIT OR MANOMETER TEST DOCUMENT | | | REQUIRED AT JOBSITE FOR FINAL INSPECTION. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2018-10-03 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-10-03 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-10-03 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2018-10-03 17:15:39 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE MANUFACTURE SPECIFICATION AND INSTALLATION | | | GUIDES FOR GENERATOR, REGULATORS, SUCTION AND RETURN | | | PUMPS, THE DUAL WALL PIPING WITH LEAK DETECTION, | | | GEOFLEX PIPING, AND ANY NEW EQUIPMENT ON THE FUEL TANK | | | SUCH AS THE ANTI SIPHON VALVE AND FOOT VALVE. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 2. PLEASE SHOW THE EXISTING BTU LOAD ON THE EXISTING | | | PIPE. PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. ON THE NATURAL GAS RISER PLEASE SHOW THE FOLLOWING: | | | A) THE FURTHEST DISTANCE FROM THE METER TO THE LAST | | | GENERATOR. | | | B) SHOW THE BRANCHES FOR ALL 3 GENERATORS. | | | C) INDICATE SYSTEM PRESSURE. | | | D) SHOW DISTANCE AND SIZE OF PIPE FROM REGULATOR TO THE | | | GENERATOR. | | | E) INDICATE BTU LOAD ON EACH GENERATOR. | | | PER WPB AMEND TO FBC 107.2.1 | | | 4. PLEASE NOTE ON THE PLAN THE SIZING TABLE USED FROM | | | FBC FG 402.4 | | | | | | 5. EXPOSED PIPING SHALL BE LABELED AS NATURAL GAS OR | | | DIESEL. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2019-03-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-03-05 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-03-04 |
Time |
10:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-02-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-02-19 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-01-17 |
Time |
08:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-12-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-12-28 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-11-20 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-10-16 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2018-10-16 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-09-17 |
Time |
10:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2019-02-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-02-19 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-02-19 |
Time |
08:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2018-12-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-12-28 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-12-28 |
Time |
12:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2019-03-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-03-05 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-03-05 |
Time |
08:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2019-02-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2019-02-16 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2019-02-16 |
Time |
12:34 |
Sent To |
|
|
| Notes |
| 2019-02-16 12:34:42 | DIGITALLY SIGNATURES OK | | | NEW SHEETS SUBMITTED NEXT REVIEW CYCLE REQUIRE REVIEW | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2018-12-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-27 |
Time |
18:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-27 |
Time |
18:59 |
Sent To |
|
|
| Notes |
| 2018-12-27 18:59:47 | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | G001 IS NOT DIGITALLY SIGNED | | | A121 IS NOT DIGITALLY SIGNED | | | S, E, P SHEETS OK | | | NEW SHEETS SUBMITTED NEXT REVIEW CYCLE REQUIRE | | | VERIFICATION | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2018-10-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-10-04 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-10-04 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2018-10-04 14:06:16 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. THE SIGNATURE AND SEAL OF THE DESIGNER OF RECORD IS | | | INVALID FOR THE FOLLOWING PLAN PAGES: | | | A. G-001 | | | B. A-121 | | | C. CIVIL PAGES 1 AND 2 | | | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2019-03-01 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2019-01-25 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2019-01-25 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2019-01-25 09:19:00 | PROVISO: PROPOSED GENERATOR WILL REMOVE FOUR EXISTING | | | PARKING SPACES. PLEASE INCLUDE INFORMATION INDICATING | | | WHERE THE PARKING SPACES ARE GOING TO BE RELOCATED, OR | | | PROVIDE A PARKIGN CALCULATION TO DEMONSTRATE THE FOUR | | | SPACES WERE NOT MINIMUM REQUIRED PARKING.CALCULATION | | | SHALL BE PROVIDED AND SUBMITTED AS A REVISION FOR | | | APPROVAL BEFORE FINAL CERTIFICATE OF COMPLETION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-12-18 |
|
|
Cont ID |
|
| Sent By |
elevesqu |
Date |
2018-12-18 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
elevesqu |
Date |
2018-12-18 |
Time |
10:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2018-10-16 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2018-10-16 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2018-10-16 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|