Plan Review Details - Permit 18081446
| Plan Review Stops For Permit 18081446 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-09-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-09-24 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-09-24 |
Time |
09:47 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-09-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-09-12 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-09-12 |
Time |
14:08 |
Sent To |
I |
|
| Notes |
| 2018-09-12 14:12:26 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE SITE PLAN. SHOW LOCATION OF SHED ON | | | PROPERTY. | | | 2. PROVIDE DEMENSIONS TO PROPERTY LINES AND OTHER | | | STRUCTURES ON PROPERTY. | | | | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED ON A BOUNDARY LINE SURVEY. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-09-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-09-24 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-09-20 |
Time |
14:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-09-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-09-12 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-08-29 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2018-08-30 13:48:15 | ROUTED TO ZONING INBOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-09-20 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-09-20 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-09-20 |
Time |
14:05 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-09-06 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2018-09-06 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2018-09-06 |
Time |
10:21 |
Sent To |
B |
|
| Notes |
| 2018-09-06 10:26:06 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | | | 1) PROVIDE TWO COPIES OF A SURVEY. | | | 2) INDICATE ON THE SURVEY THE LOCATION OF THE PROPOSED | | | SHED. | | | | | | NOTE: SHEDS SHALL BE SETBACK AT LEASE 5' FROM SIDE AND | | | REAR PROPERTY LINES AND AT LEAST 6' FROM PRINCIPAL | | | STRUCTURE. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ | | | ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1442 | | | E-MAIL: [email protected] |
|
|
|