Plan Review Details - Permit 18081402
Plan Review Stops For Permit 18081402
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-02-14 Cont ID  
Sent By jgomez Date 2019-02-14 Time 10:16 Rev Time 0.00
Received By jgomez Date 2019-02-13 Time 18:20 Sent To  
Notes
2019-02-14 10:18:26BUILDING REVIEW APPROVED WITH PROVISO:
 1- GAF SINGLE PLY PLY ROOFING SYSTEMS NOA 18-0523.05
 SUBMITTED. PROVIDE SIGNED AND SEALED RAS 117
 CALCULATIONS AS REQUIRED BY GENERAL LIMITATION #7.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-01-17 Cont ID  
Sent By jgomez Date 2019-01-17 Time 18:30 Rev Time 0.00
Received By jgomez Date 2019-01-17 Time 11:37 Sent To  
Notes
2019-01-17 18:31:19NEW BUILDING (GROUP B) SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
  
 PROVISO NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
  
 1- OK.
  
 2- TO BE DONE LATER BEFORE ISSUING PERMIT.
  
 3- SOIL TEST REPORT SUBMITTED NEEDS SURVEYORS ORIGINAL
 SEAL AND SIGNATURE OR DIGITAL SIGNATURE WHEN SUBMITTING
 DOCUMENTS FOR PUBLIC RECORDS. CHAPTER 472 F.S.
  
 4- OK.
  
 5- ENERGY CALCULATIONS FORM SUBMITTED:
 A) PLANS NEED TO SPECIFY THE INSULATION R VALUE OF
 EXTERIOR WALLS. NOTE: ARCHITECT AND ENGINEER PREPARING
 THE ENERGY CALCULATIONS TO COORDINATE INFORMATION TO
 AVOID CONFLICTS/DELAYS. THIS APPLIES TO CEILING
 INSULATION ALSO. SEC. C103.2 FBC-ENERGY CONSERVATION.
  
 RESPONSE:
 PARTIALLY DONE. ARCHITECT PROVIDED INFORMATION ON SHEET
 A.05 BUT INFORMATION SHOWN ON THE ENERGY CALCULATIONS
 AND ARCHITECTURAL PLANS DON'T MATCH. ARCHITECT AND
 ENGINEER TO COORDINATE TO AVOID MORE CONFLICTS/DELAYS.
  
 B)ARCHITECT OF RECORD TO CERTIFY (SIGNATURE AND LICENSE
 NUMBER) ON ENERGY FORM AS REQUIRED BY SEC. C103.1.1.1.2
 FBC-ENERGY CONSERVATION.
  
 RESPONSE:
 REPEAT COMMENT. NOT DONE.
  
 C) THE BUILDING OWNER OR LEGALLY AUTHORIZED AGENT NEEDS
 TO CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH THE
 ENERGY CODE AS REQUIRED BY SEC. C103.1.1.2 FBC-ENERGY
 CONSERVATION PRIOR TO RECEIVING THE PERMIT TO BEGIN
 CONSTRUCTION.
  
 RESPONSE:
 REPEAT COMMENT. NOT DONE.
  
 D) ENGINEER OF RECORD PERFORMING THE ENERGY
 CALCULATIONS TO COORDINATE WITH ARCHITECTURAL PLANS TO
 AVOID CONFLICTS/DELAYS. INFORMATION FOR WALLS AND
 CEILING INSULATION R VALUE DOESN'T MATCH. SEC. 107.2.1
 CITY AMENDMENTS. ALSO, CHECK THE PROPER BOXES IN THE
 MANDATORY SECTION.
  
 RESPONSE:
 REPEAT COMMENT. NOT DONE.
  
 6- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR
 INTERIOR WINDOWS SHOWN ON FLOOR PLANS. INCLUDE FRAMING
 DETAILS AND GLAZING SPECIFICATIONS. SEC. 2406 FBC.
  
 RESPONSE:
 RESPONSE LETTER STATES ""PLEASE SEE REVIEWED NOA".
 CLARIFY IF INSTALLING SAME TYPE OF WINDOWS AS THE ONES
 USED FOR THE EXTERIOR. PROVIDE CLEAR SPECIFICATIONS IN
 THE WINDOW SHELLED ON SHEET A.13.
  
 7- OK.
  
 8- OK.
  
 9- OK.
  
 10- DUMPSTER STRUCTURAL PLANS SHOWN ON SHEET A.03 DON'T
 MATCH STRUCTURAL PLANS SHOWN ON SHEET S.01. REVISE AS
 REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 STILL DON'T MATCH. REVISE AS REQUIRED TO MATCH (SEE
 DIMENSIONS AND STRUCTURAL SPECIFICATIONS) OR PROVIDE
 ONLY ONE DETAIL TO AVOID CONFLICTS.
  
 11- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL)
  
 A)GAF SINGLE PLY PLY ROOFING SYSTEMS NOA 18-0523.05
 SUBMITTED. PROVIDE SIGNED AND SEALED RAS 117
 CALCULATIONS AS REQUIRED BY GENERAL LIMITATION #7.
 SEC. 1609 FBC.
  
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-11-16 Cont ID  
Sent By jgomez Date 2018-11-16 Time 13:04 Rev Time 0.00
Received By jgomez Date 2018-11-15 Time 10:26 Sent To  
Notes
2018-11-16 13:16:17NEW BUILDING (GROUP B) BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1-ART IN PUBLIC SPACES.
 PLEASE REVIEW ART IN PUBLIC PLACES. THE CITY OF WEST
 PALM BEACH ART IN PUBLIC PLACES ORDINANCE REQUIREMENT
 THAT APPLIES TO ANY REMODEL OR NEW CONSTRUCTION PROJECT
 FOR WHICH THE PERMIT APPLICATION WAS SUBMITTED AFTER
 6/29/14, AND THE TOTAL PROJECT CONSTRUCTION COSTS ARE
 EQUAL TO OR GREATER THAN $750,000 WILL NEED TO COMPLY
 WITH THIS ORDINANCE.
 PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND
 CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V,
 ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION
 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL
 PROJECT CONSTRUCTION COST.
 PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE
 V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND
 NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO
 THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE
 PROJECTS.
 FOR CONTACT INFORMATION PLEASE CONTACT:
 MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR
 822-1515 E-MAIL: [email protected]
  
 2- IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 3- PROVIDE COPY OF SOIL TEST REPORT SPECIFIED ON
 FOUNDATION NOTES ON SHEET S.03.
 SEC. 1803.1 FBC.
  
 4- SITE PLAN ON SHEET A.02 SHOWS 10'X20' LOADING ZONE
 IN THE MIDDLE OF THE PARKING LOT. THIS LOADING AREA IS
 BLOCKING THE ACCESSIBLE PARKING SPACE. REVISE AS
 REQUIRED. SEC. 206.1 FBC-ACCESSIBILITY.
  
 5- ENERGY CALCULATIONS:
 A) PLANS NEED TO SPECIFY THE INSULATION R VALUE OF
 EXTERIOR WALLS. NOTE: ARCHITECT AND ENGINEER PREPARING
 THE ENERGY CALCULATIONS TO COORDINATE INFORMATION TO
 AVOID CONFLICTS/DELAYS. THIS APPLIES TO CEILING
 INSULATION ALSO. SEC. C103.2 FBC-ENERGY CONSERVATION.
  
 B)ARCHITECT OF RECORD TO CERTIFY (SIGNATURE AND LICENSE
 NUMBER) ON ENERGY FORM AS REQUIRED BY SEC. C103.1.1.1.2
 FBC-ENERGY CONSERVATION.
  
 C) THE BUILDING OWNER OR LEGALLY AUTHORIZED AGENT NEEDS
 TO CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH THE
 ENERGY CODE AS REQUIRED BY SEC. C103.1.1.2 FBC-ENERGY
 CONSERVATION PRIOR TO RECEIVING THE PERMIT TO BEGIN
 CONSTRUCTION.
  
 D) ENGINEER OF RECORD PERFORMING THE ENERGY
 CALCULATIONS TO COORDINATE WITH ARCHITECTURAL PLANS TO
 AVOID CONFLICTS/DELAYS. INFORMATION FOR WALLS AND
 CEILING INSULATION R VALUE DOESN'T MATCH. SEC. 107.2.1
 CITY AMENDMENTS. ALSO, CHECK THE PROPER BOXES IN THE
 MANDATORY SECTION.
  
 6- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR
 INTERIOR WINDOWS SHOWN ON FLOOR PLANS. INCLUDE FRAMING
 DETAILS AND GLAZING SPECIFICATIONS. SEC. 2406 FBC.
  
 7- SHEET A.08: PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS FOR THE FASTENING OF THE METAL PARAPET
 CAP AND (2)2X10P.T. WOOD BLOCKING. SEC. 1609.1 FBC.
  
 8- LADDER TO ACCESS A/C EQUIPMENT ON THE UPPER ROOF
 NEED TO EXTEND NOT LESS THAN 30INCHES. LADDERS NEED TO
 BE CONSTRUCTED AS REQUIRED BY SEC. 306.5
 FBC-MECHANICAL. (SEE SEC. 1011.16 FBC). NOTE:
 COORDINATE WITH MECHANICAL PLANS EXAMINER/INSPECTOR TO
 AVOID CONFLICTS/ DELAYS.
  
 9- CLARIFY IF TENANT SEPARATION WALL BETWEEN
 MISCELLANEOUS SPACE 1 AND MISCELLANEOUS SPACE 2 IS
 GOING TO BE A FIRE RATED WALL OR NOT. WALL TYPE 5 ON
 SHEET A.06 DOESN'T PROVIDE SPECS FOR A FIRE RATED
 ASSEMBLY BUT LIFE SAFETY PLAN ON SHEET A.14 SPECIFIES
 THAT IT IS A FIRE RATED WALL. REVISE/CLARIFY AS
 REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 10- DUMPSTER STRUCTURAL PLANS SHOWN ON SHEET A.03 DON'T
 MATCH STRUCTURAL PLANS SHOWN ON SHEET S.01. REVISE AS
 REQUIRED TO MATCH. SEC. 107.2.1 CITY AMENDMENTS.
  
 11- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL)
  
 A) ALL EXTERIOR DOORS AS SHOWN ON PLANS.
  
 B) ALL WINDOWS AS SHOWN ON PLANS.
  
 C)FLAT ROOF FOR METAL DECK AND CONCRETE DECK AS SHOWN
 ON PLANS. . AND, CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. 1609 FBC. NOTE: IF THE
 SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES FOR
 ALL ROOF ZONES, THEN SIGNED AND SEALED RAS 117
 CALCULATIONS ARE REQUIRED.
  
 D) PRECAST LINTELS AS SHOWN ON PLANS.
  
 E) HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE CITY SAMPLE.
  
 12- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2019-02-13 Cont ID  
Sent By jpearson Date 2019-02-13 Time 10:57 Rev Time 0.00
Received By jpearson Date 2019-02-13 Time 10:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-01-08 Cont ID  
Sent By jpearson Date 2019-01-08 Time 11:56 Rev Time 0.00
Received By jpearson Date 2019-01-08 Time 11:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-10-23 Cont ID  
Sent By jpearson Date 2018-10-23 Time 15:01 Rev Time 0.00
Received By jpearson Date 2018-10-23 Time 10:33 Sent To  
Notes
2018-10-23 15:01:04CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH
 PANEL INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE.
 NEC 110.9, 110.10
 2. PROVIDE SHOW WINDOW OUTLETS PER NEC 210.62.
 3. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS,
 DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD
 SYSTEMS, WALK IN COOLERS, SIGNS, SITE LIGHTING, AND
 SWIMMING POOLS (WHERE APPLICABLE) ARE NOT INCLUDED IN
 THE SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE
 INDICATING THE REQUIRED SEPARATE PERMITS AND PLAN
 SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. WPB FBC
 105.1, 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2019-01-18 Cont ID  
Sent By jgomez Date 2019-01-18 Time 08:58 Rev Time 0.00
Received By mgonzale Date 2019-01-18 Time 08:57 Sent To  
Notes
2019-01-18 08:58:29PLANS UNDER REVIEW AT ENGINEERING SERVICES DEPT.
  
 [email protected]
 (561)818-1322

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2018-11-19 Cont ID  
Sent By Mgonzale Date 2018-11-19 Time   Rev Time  
Received By mgonzale Date 2018-11-19 Time   Sent To I
Notes
2018-11-19 09:56:21PLANS UNDER REVIEW AT ENGINEERING SERVICES DEPT.
  
 [email protected]
 (561)818-1322

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-12-20 Cont ID  
Sent By scaldero Date 2018-12-20 Time 09:27 Rev Time 0.00
Received By scaldero Date 2018-12-20 Time 09:24 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-09-25 Cont ID  
Sent By scaldero Date 2018-09-25 Time 14:17 Rev Time 0.00
Received By scaldero Date 2018-09-21 Time 14:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-02-20 Cont ID  
Sent By shill Date 2019-02-20 Time 11:59 Rev Time 0.00
Received By shill Date 2019-01-25 Time 14:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-01-18 Cont ID  
Sent By jgomez Date 2019-01-18 Time 08:59 Rev Time 0.00
Received By jgomez Date 2018-12-18 Time 12:54 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-11-26 Cont ID  
Sent By cpuell Date 2018-11-26 Time 15:59 Rev Time 0.00
Received By cpuell Date 2018-09-19 Time 09:56 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2019-03-06 Cont ID  
Sent By lmarchan Date 2019-03-06 Time 10:10 Rev Time 0.00
Received By lmarchan Date 2019-02-13 Time 14:00 Sent To  
Notes
2019-03-06 10:11:22RECEIPT 2019-0301-252 - $8756.13 PAID
2019-02-13 14:00:222/13/19 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2019-01-17 Cont ID  
Sent By jgomez Date 2019-01-17 Time 18:42 Rev Time 0.00
Received By jgomez Date 2019-01-17 Time 18:42 Sent To  
Notes
2018-12-21 08:54:50IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-11-16 Cont ID  
Sent By jgomez Date 2018-11-16 Time 17:01 Rev Time 0.00
Received By jgomez Date 2018-11-16 Time 17:01 Sent To  
Notes
2018-11-16 17:01:20IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2019-02-15 Cont ID  
Sent By shill Date 2019-02-15 Time 17:26 Rev Time 0.00
Received By shill Date 2019-02-15 Time 17:26 Sent To  
Notes
2019-02-15 17:27:45PROVISO: NEW SHEETS OK; IF THERE IS ANOTHER REVIEW
 CYCLE, NEW SHEETS REQUIRE VERIFICATION
 SHEET A.01 PROVIDED AS PAPER ORIGINAL
 SOILS REPORT PROVIDED AS PAPER ORIGINAL
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-01-03 Cont ID  
Sent By hmoser Date 2019-01-03 Time 10:18 Rev Time 0.00
Received By hmoser Date 2019-01-02 Time 14:58 Sent To  
Notes
2019-01-03 10:18:36PASS PROVISO
 1) PROVIDE RETURN AIR IN STAFF ROOM # 7
 PER SECTION 601.6 BALANCED RETURN AIR.
 2017 FBC (M)
 2) REFER TO SECTION 601.6 BALANCED RETURN AIR
 IN RECEPTION ROOM. 2017 FBC (M)
 3) REFER TO SECTION 606.2 WHERE REQUIRED
 PROVIDE LITERATURE ON AIR HANDLER # 1 SHOWING
 FAN SPEEDS.
 HAVE INFORMATION ON SITE AT 1ST INSPECTION.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2018-11-01 Cont ID  
Sent By hmoser Date 2018-11-01 Time 08:44 Rev Time 0.00
Received By hmoser Date 2018-10-31 Time 11:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2019-02-19 Cont ID  
Sent By gjohnson Date 2019-02-19 Time 16:11 Rev Time 0.00
Received By gjohnson Date 2019-02-19 Time 16:11 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-01-17 Cont ID  
Sent By gjohnson Date 2019-01-17 Time 10:42 Rev Time 0.00
Received By gjohnson Date 2019-01-17 Time 09:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-11-13 Cont ID  
Sent By gjohnson Date 2018-11-13 Time 09:51 Rev Time 0.00
Received By gjohnson Date 2018-11-13 Time 09:51 Sent To  
Notes
2018-11-13 09:51:411ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. THE SINGLE OCCUPANT BATHROOM IN THE PRIVATE OFFICE
 #2 IS REQUIRED TO COMPLY WITH SOME ACCESSIBILITY.
 A) THE DOOR SHALL COMPLY WITH FBC ACC 603.2.3 EXCEPTION
 #1.
 B) THE EXCEPTIONS FOR THE SINGLE OCCUPANT BATHROOM ARE
 THE FOLLOWING.
 1) THE HEIGHT OF THE TOILET FBC ACC 604.4 EXCEPTION #1
 2) THE GRAB BAR DO NOT NEED TO BE INSTALLED BUT THE
 REINFORCEMENT BACKING SHALL BE INSTALLED IN THE WALLS.
 FBC ACC 604.5 EXCEPTION #1
 3) THE LAVATORY FBC ACC 606.2 EXCEPTION #2 606.3
 EXCEPTION #1
 C) !!!!THESE ARE REQUIRED SHOW COMPLIANCE WITH THE
 FOLLOWING!!!!
 1) THE TOILET SHALL COMPLY WITH FBC ACC 604.2
 LOCATION.THE WATER CLOSET SHALL BE POSITIONED WITH A
 WALL OR PARTITION TO THE REAR AND TO ONE SIDE. THE
 CENTERLINE OF THE WATER CLOSET SHALL BE 16 INCHES (405
 MM) MINIMUM TO 18 INCHES MAXIMUM FROM THE SIDE WALL OR
 PARTITION,
 2) THE TOILET SHALL COMPLY WITH FBC ACC 604.3.1 SIZE.
 CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES
 MINIMUM MEASURED PERPENDICULAR FROM THE SIDE WALL AND
 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE REAR
 WALL.
 AND FBC ACC 604.3.2 OVERLAP. THE REQUIRED CLEARANCE
 AROUND THE WATER CLOSET SHALL BE PERMITTED TO OVERLAP
 THE WATER CLOSET, ASSOCIATED GRAB BARS, DISPENSERS,
 SANITARY NAPKIN DISPOSAL UNITS, COAT HOOKS, SHELVES,
 ACCESSIBLE ROUTES, CLEAR FLOOR SPACE AND CLEARANCES
 REQUIRED AT OTHER FIXTURES, AND THE TURNING SPACE. NO
 OTHER FIXTURES OR OBSTRUCTIONS SHALL BE LOCATED WITHIN
 THE REQUIRED WATER CLOSET CLEARANCE.
  
 2. ALL BATHROOMS SHALL COMPLY WITH FBC ACC 604.7
 DISPENSERS. TOILET PAPER DISPENSERS SHALL COMPLY WITH
 309.4 AND SHALL BE 7 INCHES MINIMUM AND 9 INCHES
 MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE
 CENTERLINE OF THE DISPENSER.
  
 3. THE GRAB BARS IN THE COMMON BATHROOMS SHALL COMPLY
 WITH FBC ACC 604.5.1 SIDE WALL. THE SIDE WALL GRAB BAR
 SHALL BE 42 INCHES LONG MINIMUM, LOCATED 12 INCHES
 MAXIMUM FROM THE REAR WALL AND EXTENDING 54 INCHES
 MINIMUM FROM THE REAR WALL.
 604.5.2 REAR WALL. THE REAR WALL GRAB BAR SHALL BE 36
 INCHES LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF
 THE WATER CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24
 INCHES MINIMUM ON THE OTHER SIDE.
  
 4. THE GRAB BARS SHALL BE MEASURED TO THE TOP OF THE
 GRIPPING SURFACE. PER FBC ACC 609.4
  
 5. THE BREAK ROOM SINK SHALL COMPLY WITH FBC ACC 606.2
 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE COMPLYING WITH,
 POSITIONED FOR A FORWARD APPROACH, AND KNEE AND TOE
 CLEARANCE COMPLYING WITH SHALL BE PROVIDED.
 606.3 HEIGHT. LAVATORIES AND SINKS SHALL BE INSTALLED
 WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER
 SURFACE 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2019-01-17 Cont ID  
Sent By jgomez Date 2019-01-17 Time 18:33 Rev Time 0.00
Received By jgomez Date 2019-01-17 Time 18:31 Sent To  
Notes
2019-01-17 18:33:47GAF SINGLE PLY PLY ROOFING SYSTEMS NOA 18-0523.05
 SUBMITTED.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2018-11-16 Cont ID  
Sent By jgomez Date 2018-11-16 Time 17:01 Rev Time 0.00
Received By jgomez Date 2018-11-16 Time 17:01 Sent To  
Notes
2018-11-16 17:02:261- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL)
  
 A) FLAT ROOF FOR METAL DECK AND CONCRETE DECK AS SHOWN
 ON PLANS. . AND, CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. 1609 FBC. NOTE: IF THE
 SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES FOR
 ALL ROOF ZONES, THEN SIGNED AND SEALED RAS 117
 CALCULATIONS ARE REQUIRED.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2019-02-20 Cont ID  
Sent By shill Date 2019-02-20 Time 11:59 Rev Time 0.00
Received By shill Date 2019-02-20 Time 11:59 Sent To  
Notes
2019-02-15 11:01:022/14/19 HARD COPY ROUTED TO JGOMEZ FOR REVIEW. LEM

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2019-02-14 Cont ID  
Sent By jgomez Date 2019-02-14 Time 11:01 Rev Time 0.00
Received By jgomez Date 2019-02-14 Time 10:18 Sent To  
Notes
2019-02-14 10:18:551) NEED ARCHITECT'S DIGITAL SIGNATURE ON SHEET A.01
 TITLE SHEET.
  
 2) SOIL TEST REPORT SUBMITTED NEEDS SURVEYORS ORIGINAL
 SEAL AND SIGNATURE OR DIGITAL SIGNATURE WHEN SUBMITTING
 DOCUMENTS FOR PUBLIC RECORDS. CHAPTER 472 F.S.
2019-02-13 12:34:00ELECTRICAL SHEETS OK.
  
2019-02-13 11:14:06LANDSCAPING SIGNATURES NOT REQUIRED AS A SEPARATE
 PERMIT WILL BE APPLICAD FOR.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2019-01-08 Cont ID  
Sent By jpearson Date 2019-01-08 Time 09:53 Rev Time 0.00
Received By jpearson Date 2019-01-08 Time 09:53 Sent To  
Notes
2019-01-08 09:53:31PLAN IS REQUIRED TO BE SIGNED AND SEALED BY THE PERSON
 RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN REQUIRES A
 DIGITAL SIGNATURE WITH THE PROPER THIRD PARTY
 VERIFICATION. SHEETS A.01, L1.0, L1.1, L1.2, E.02,
 E.03, E.04, M.01, AND P.02 NEED CORRECTION. PROVIDE
 CORRECTION. WPB FBC 107.1; FS 471/481

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2018-10-23 Cont ID  
Sent By jpearson Date 2018-10-23 Time 14:17 Rev Time 0.00
Received By jpearson Date 2018-10-23 Time 14:17 Sent To  
Notes
2018-10-23 14:17:22PLAN IS REQUIRED TO BE SIGNED AND SEALED BY THE PERSON
 RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN REQUIRES A
 DIGITAL SIGNATURE. SHEETS A.01, L1.0, L1.1, AND L1.2
 ARE MISSING THE REQUIRED SIGNATURES. PROVIDE
 CORRECTION. WPB FBC 107.1; FS 471/481

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 1 Status N Date 2019-04-10 Cont ID  
Sent By jgomez Date 2019-04-10 Time 09:07 Rev Time 0.00
Received By jgomez Date 2019-04-10 Time 09:03 Sent To  
Notes
2019-04-10 09:10:05SUBMITTAL BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- RESIDENT INSPECTOR AGREEMENT SUBMITTED NEEDS TO BE
 ORIGINAL. COPIES ARE NOT ALLOWED. PROVIDE THREE
 ORIGINAL LETTERS.
 NOTE: SPECIAL INSPECTOR IS NOT REQUIRED FOR THIS
 BUILDING. THIS IS VOLUNTARILY REQUESTED BY THE
 CONTRACTOR.
  
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop Z ZONING
Rev No 3 Status P Date   Cont ID  
Sent By awooten Date 2019-02-11 Time   Rev Time 0.00
Received By awooten Date 2019-02-11 Time 14:28 Sent To  
Notes
2019-02-11 14:24:56**************************ZONING
 REVIEW*******************************
  
 LANDSCAPE PLANS SHOULD BE SUBMITTED AS A SEPARATE
 PERMIT TO BE REVIEWED BY THE CITY'S LANDSCAPE ENGINEER.
 THERE WAS AN APPROVED LANDSCAPE PLAN THAT WAS WITH THE
 SITE PLAN. PLACED A HOLD ON THE CO FOR FINAL LANDSCAPE
 INSPECTION.
  
  
 THANKS,
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2019-01-07 Cont ID  
Sent By awooten Date 2019-01-07 Time   Rev Time 0.00
Received By awooten Date 2019-01-07 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By awooten Date 2018-11-26 Time   Rev Time  
Received By   Date 2018-11-26 Time   Sent To  
Notes
2018-11-26 15:53:36**********************ZONING REVIEW
 FAILED**************************
  
 THERE WAS A CONDITION OF APPROVAL FOR THIS SITE PLAN,
 THAT THE ENTIRE EXISTING SIDEWALK ON S. DIXIE HWY WILL
 BE REPLACED WITH CONCRETE.
  
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449