| Plan Review Stops For Permit 18080928 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2019-02-26 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2019-02-26 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2019-02-26 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2019-02-26 08:59:47 | MET WITH CHRIS THROOP TO DISCUSS PREVIOUS NOTES AND NEW | | | SUBMISSION. ITEMS REMAINING: | | | NEED ROOFING MATERIAL NOA | | | NEED ROOFING SUB PERMIT | | | NEED PLUMBING SUB PERMIT | | | PLANS NOTED FOR CODE REQUIREMENTS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2019-02-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-08 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-08 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2019-02-08 15:08:54 | BUILDING PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SUBMIT PLANS BASED ON THE CURRENT CODES. | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | 2. DESIGN PROFESSIONALS SIGNATURE AND SEAL IS INVALID. | | | 3. DESIGN PROFESSIONAL TO REVIEW AND APPROVE PLANS | | | BASED ON THE CURRENT CODES. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | ***ADVIORY*** POSSIBLE 4X FEE MAY BE APPLIED. SEE | | | BELOW. | | | | | | F.S. 553.80 (2) (B) | | | (B)?WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-12-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-12-08 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-12-08 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2018-12-08 11:41:35 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 2ND REVIEW; SAME PLANS SUBMITTED. IN OUR SYSTEM, ONLY A | | | MONOLITHIC SLAB WAS INSPECTED UNDER EXPIRED PERMIT | | | 08060247. THE WIND DESIGN CRITERIA HAS CHANGED SO THE | | | OLD PLANS CANNOT BE REUSED. THE PROPOSED ADDITION IS TO | | | COMPLY WITH FBC 2017. SEE COMMENTS FROM PREVIOUS LIST: | | | | | | 1. THE PLANS SUBMITTED WERE DESIGNED TO A GOVERNING | | | CODE OF FBC 2004. THIS IS OUTDATED BY THREE CODE | | | CYCLES. PLEASE HAVE PLANS UPDATED TO COMPLY WITH THE | | | CURRENT CODE, FBC 2017. | | | | | | A BUILDING REVIEW HAS NOT BEEN DONE. ALL PLAN REVIEWS | | | WILL BE DONE AFTER THE PLANS ARE UPDATED TO REFLECT THE | | | CORRECT CODE. | | | | | | 2. THE STRUCTURE WAS DESIGNED TO 140MPH VASD, EXPOSURE | | | B. DUE TO CHANGES IN THE CODE, THIS IS NOW LOCATED IN | | | EXPOSURE C. THEREFORE THE STRUCTURAL DESIGN NEEDS TO BE | | | EVALUATED AND PLANS REVISED TO SHOW COMPLIANCE WITH THE | | | NEW WIND DESIGN CRITERIA (170MPH VULT, EXPOSURE C). | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-08-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-25 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-25 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2018-08-25 10:33:56 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. THE PLANS SUBMITTED WERE DESIGNED TO A GOVERNING | | | CODE OF FBC 2004. THIS IS OUTDATED BY THREE CODE | | | CYCLES. PLEASE HAVE PLANS UPDATED TO COMPLY WITH THE | | | CURRENT CODE, FBC 2017. | | | | | | A BUILDING REVIEW HAS NOT BEEN DONE. ALL PLAN REVIEWS | | | WILL BE DONE AFTER THE PLANS ARE UPDATED TO REFLECT THE | | | CORRECT CODE. | | | | | | 2. THE STRUCTURE WAS DESIGNED TO 140MPH VASD, EXPOSURE | | | B. DUE TO CHANGES IN THE CODE, THIS IS NOW LOCATED IN | | | EXPOSURE C. THEREFORE THE STRUCTURAL DESIGN NEEDS TO BE | | | EVALUATED AND PLANS REVISED TO SHOW COMPLIANCE WITH THE | | | NEW WIND DESIGN CRITERIA (170MPH VULT, EXPOSURE C). | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2019-02-26 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2019-02-26 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2019-02-26 |
Time |
09:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-02-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-08 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-02-08 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2019-02-08 15:12:13 | ELECTRICAL PLAN REVIEW | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER, PX3169 | | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE ELECTRICAL PLAN BASED ON THE CURRENT CODES. | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | | EDITION | | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-11-29 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-11-29 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-11-29 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2018-11-29 13:44:21 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | | 6TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW SIGNED BY PERSON | | | RESPONSIBLE FOR THE DESIGN. FS 481.229; WPB FBC 107.1, | | | 107.2.1, 107.3.5.1.2 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2019-02-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2019-02-08 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2019-01-23 |
Time |
16:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-12-11 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-12-11 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-10-31 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2018-12-08 11:42:11 | 12/8 REMOVED FROM BOARD; ROUTED TO LC DESK / S.HILL | | | | | | | | 2018-11-01 16:07:41 | R38 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-08-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-08-25 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-08-17 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2018-08-24 09:13:23 | 8/24 TO SAK DESK | | | REMOVED FROM BOARD - NEEDS UPDATED PLANS | | | | | | | | 2018-08-21 14:06:41 | R33 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
P |
Date |
2019-02-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-12-08 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2018-12-08 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2018-12-08 11:44:20 | NO ACTION FROM APPLICANT IS REQUIRED | | | | | | NOTE TO BUILDING PLANS EXAMINER: | | | | | | IMPACT FEES WERE PASSED UNDER 08060247. PRIOR TO | | | ISSUANCE OF THIS PERMIT, CONFIRM THAT THIS PERMIT | | | RECORD INCLUDES THE STAMPED PLAN FROM 08060247 AND | | | RECEIPT. CONFIRM THAT THE SIZE OF ADDITION UNDER THIS | | | PERMIT IS THE SAME AS 08060247 (460 SF). |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2019-02-26 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2019-02-26 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2019-02-26 |
Time |
09:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2019-02-04 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2019-02-04 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-02-04 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2019-02-04 14:52:24 | NEED UPDATED PLANS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-11-06 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2018-11-06 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2019-02-04 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2018-11-06 14:38:08 | MECHANICAL PLAN REVIEW FAIL | | | | | | 1 - NEED MECHANICAL PLAN PER 2017 FLORIDA BUILDING CODE | | | SEC [A]107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | | | | CHRIS MONTELLO | | | 561-805-6673 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2019-02-26 |
|
|
Cont ID |
|
| Sent By |
dharvey |
Date |
2019-02-26 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
dharvey |
Date |
2019-02-26 |
Time |
09:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2019-02-05 |
|
|
Cont ID |
|
| Sent By |
jesmith |
Date |
2019-02-05 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
jesmith |
Date |
2019-02-05 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2019-02-05 10:07:29 | CODES IN EFFECT | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | | EDITION | | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | | FAC= FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | 3RD REVIEW; DENIED | | | COMMENTS: | | | 1. SINCE PLANS WERE PREPARED BY AN ARCHITECT, CLEAN OR | | | NEW CONSTRUCTION DOCUMENTS SHALL BE PREPARED, SIGNED | | | AND SEALED BY AN ARCHITECT AS REQUIRED BY CHAPTER 481, | | | FLORIDA STATUTES & 61G1 FLORIDA ADMINISTRATIVE CODE AND | | | SUBMITTED FOR PUBLIC RECORD IN ACCORDANCE WITH WPB FBC | | | 107.1 AND 107.2.1. SAID DOCUMENTS SHALL COMPLY WITH | | | 2017 FBC 6TH EDITION. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | JERALD SMITH | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | EMAIL [email protected] PHONE | | | 561-805-6715 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2018-12-11 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-12-11 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-12-11 |
Time |
07:24 |
Sent To |
|
|
| Notes |
| 2018-12-11 07:24:43 | 12/11/2018 2ND PLUMBING REVIEW **DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. SECOND REQUEST, SIGNATURE OF AN ARCHITECT-ENGINEER | | | IS REQUIRED (OR SEAL, OR TITLE BLOCK, OR ALL THREE) ARE | | | NOT IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODE | | | 61G15-23.001, FLORIDA STATUTE 471.2. | | | 2. SHOWER CONTROL VALVES SHALL BE PRESSURE-BALANCE, | | | THERMOSTATIC-MIXING OR COMBINATION | | | PRESSURE-BALANCE/THERMOSTATIC-MIXING VALVE TYPES WITH A | | | HIGH LIMIT STOP IN ACCORDANCE WITH ASSE 1016/ASME | | | A112.1016/CSA B125.16. THE HIGH LIMIT STOP SHALL BE SET | | | TO LIMIT THE WATER TEMPERATURE TO NOT GREATER THAN | | | 120?F. | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-08-24 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-08-24 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-08-24 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2018-08-24 07:28:54 | 8/24/2018 1ST PLUMBING REVIEW **DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. GOVERNING CODES HAVE CHANGE SINCE 2004 PLEASE UPDATE | | | PLANS TO REFLECT 2017 FBC 6TH EDITION. | | | 2. SHOWER CONTROL VALVES SHALL BE PRESSURE-BALANCE, | | | THERMOSTATIC-MIXING OR COMBINATION | | | PRESSURE-BALANCE/THERMOSTATIC-MIXING VALVE TYPES WITH A | | | HIGH LIMIT STOP IN ACCORDANCE WITH ASSE 1016/ASME | | | A112.1016/CSA B125.16. THE HIGH LIMIT STOP SHALL BE SET | | | TO LIMIT THE WATER TEMPERATURE TO NOT GREATER THAN | | | 120?F. | | | 3. SIGNATURE OF AN ARCHITECT-ENGINEER IS REQUIRED (OR | | | SEAL, OR TITLE BLOCK, OR ALL THREE) ARE NOT IN | | | ACCORDANCE WITH FLORIDA | | | ADMINISTRATIVE CODE 61G15-23.001, FLORIDA STATUTE 471. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | | [email protected] | | | 561-805-6720 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2019-01-29 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2019-01-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2019-01-29 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-12-04 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2018-12-04 |
Time |
|
Rev Time |
|
| Received By |
awooten |
Date |
2018-12-04 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-12-04 15:09:39 | ********************************************ZONING | | | REVIEW | | | FAILED******************************************** | | | | | | PLEASE SUBMIT LANDSCAPE PLAN WITH A SEPARATE | | | LANDSCAPING PERMIT. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | 561-822-1449 | | | [email protected] | | | |
|
|