| Plan Review Stops For Permit 18080908 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-12-21 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-12-21 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2018-12-21 09:03:02 | PROVISO: | | | FLOORING UNDERLAYMENT SUBMITTAL WILL BE NEEDED FOR 2ND | | | FLOOR PRIOR TO FLOORING INSTALLATION. | | | CONTACT ME VIA E-MAIL TO GET PRE-APPROVAL OF | | | UNDERLAMENT PRIOR TO SUBMITTAL. | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER I | | | [email protected] | | | 561-805-6718 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2018-10-24 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-24 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-23 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2018-10-24 10:55:48 | ****CORRECTIONS**** | | | W.P.B. PERMIT: 18080908 | | | REVIEWED: OCTOBER 24, 2018 | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER I | | | [email protected] | | | 561-805-6718 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC ENERGY = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. [FBC 107.3.5]PROVIDE PROJECT DATA: | | | LEVEL OF ALTERATION-THIS IS LEVEL 3 ALTERATION | | | AREA OF EACH UNIT TYPE UNDER AIR. | | | OCCUPANCY TYPE | | | TYPE OF CONSTRUCTION | | | EXISTING FIRE SEPARATION OF UNITS? | | | | | | 2. UPLOAD NOA#17-1011.23 TO SUPPORTING DOCUMENTS FOLDER | | | IN PROJECT DOX. | | | | | | 3. REMOVE DOORS FROM THE WEST SIDE OF KEY PLAN SECOND | | | FLOOR. THERE WOULD BE NO DOORS ON THAT SIDE OF BUILDING | | | ON THAT LEVEL. | | | | | | 4. 702.4 WINDOW OPENING CONTROL DEVICES. | | | IN GROUP R-2 OR R-3 BUILDINGS CONTAINING DWELLING UNITS | | | AND ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES | | | REGULATED BY THE FLORIDA BUILDING CODE, RESIDENTIAL, | | | WINDOW OPENING CONTROL DEVICES COMPLYING WITH ASTM | | | F2090 SHALL BE INSTALLED WHERE AN EXISTING WINDOW IS | | | REPLACED AND WHERE ALL OF THE FOLLOWING APPLY TO THE | | | REPLACEMENT WINDOW: | | | | | | NOTE: | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | | OF MATERIALS REQUESTED. | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | | NEED "VOID", RENDERING THEM NOT USABLE. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2019-01-04 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2019-01-04 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2019-01-04 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2019-01-04 08:14:16 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING EXISTING BUILDING 2017 6TH | | | EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | | | 1. CORRECTED. | | | 2. CORRECTED. | | | 3. CORRECTED. | | | 4. CORRECTED. | | | 5. CORRECTED. | | | 6. CORRECTED. | | | 7. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. FBC 109.3 | | | (NOT PROVIDED) | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-09-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-09-26 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-09-26 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2018-09-26 16:17:58 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | | 6TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | | 6TH EDITION | | | FBC EX = FLORIDA BUILDING EXISTING BUILDING 2017 6TH | | | EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. LOAD CALCULATION FOR HOUSE PANEL SHOWS DEMAND | | | FACTORS FROM NEC 220.82. THESSE DEMAND FACTORS ARE NOT | | | PERMITTED ON FEDDERS WITH LESS THAN 100 AMPS CAPACITY. | | | PROVIDE CORRECTION. NEC 220.82 | | | 2. LOAD CALCULATION FOR PANEL B SHOWS ALL LOADS ADDED | | | TOGETHER AND THEN DEMAND FACTORS APPLIED. THE AC SHOULD | | | NOT BE INCLUDED IN THESE DEMAND FACTORS.THE LOAD FOR AC | | | SHOULD BE AT 100% OF AC, OR 65% OF HEAT, WHICHEVER IS | | | LARGER. PROVIDE CORRECTION. NEC 220.82 | | | 3. LOAD CALCULATION FOR PANEL A SHOWS THE AC AT 65%.THE | | | LOAD FOR AC SHOULD BE AT 100% OF AC, OR 65% OF HEAT, | | | WHICHEVER IS LARGER. PROVIDE CORRECTION. NEC 220.82 | | | 4. THIS APPEARS TO BE A LEVEL 2 ALTERATION, ALTHOUGH IT | | | IS SHOWN AS A REPAIR ON THE PLAN. HOWEVER, ADDITIONAL | | | AC EQUIPMENT IS BEING ADDED, SO IT WOULD APPEAR THAT IT | | | SHOULD BE LEVEL 2. PROVIDE CLARIFICATION. FBC EX 504.1 | | | 5. IF LEVEL 2 ALTERATION, PROVIDE UPGRADE OF ELECTRICAL | | | IN WORK AREAS TO INCLUDE OUTLET SPACING, AFCI AND GFCI | | | PROTECTION, AND MINIMUM LIGHTING REQUIREMENTS. FBC EX | | | 808.3; NEC 210.8, 210.12 | | | 6. IF EXISTING ELECTRICAL MEETS THE REQUIREMENTS IN | | | COMMENT 5, SHOW ON PLAN. WPB FBC 107.2.1 | | | 7. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. FBC 109.3 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | | SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2018-12-17 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-12-17 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-12-17 |
Time |
09:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2018-08-28 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2018-08-28 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2018-08-28 |
Time |
12:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2019-01-15 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-01-15 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-12-13 |
Time |
08:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2018-10-24 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-24 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-08-23 |
Time |
10:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
P |
Date |
2018-10-24 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-10-24 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-10-24 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2018-10-24 10:57:53 | NO CHANGE IN OCCUPANCY OR AREA. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2019-01-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2019-01-07 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2019-01-07 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2018-10-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-10-03 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-09-28 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2018-10-03 17:34:44 | 1ST REVIEW FBC-2017 MECHANICAL | | | PERMIT #18080908 | | | 10/3/18 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | | 2017 | | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | | 2017 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | | EDITION 2017 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) DESIGN CRITERIA: PROVIDE A LIST OF CURRENT CODES AND | | | STANDARDS USED IN THE DESIGN OF THE PROJECT. SHEET A101 | | | IS LISTING THE PROJECT AS REPAIR PER CHAPTER 6 OF THE | | | FBC EX, HOWEVER THE INSTALLATION OF NEW CENTRAL AC | | | SYSTEMS IN THE APARTMENTS IS DEEMED A LEVEL 2 | | | ALTERATION PER SECTION 504.1 FBC EX. ALSO, WINDOW | | | REPLACEMENTS ARE DEEMED LEVEL 1 ALTERATIONS PER SECTION | | | 503.1 FBC EX. PLEASE UPDATE THE CODE DATA ACCORDINGLY. | | | | | | 2) M201: INDICATE HOW ACCESS WILL BE PROVIDED TO THE | | | NEW AIR HANDLERS IN THE NEW SOFFITS- SECTION 306.1 FBC | | | M. | | | | | | 3) M201: THE RETURN TRANSFERS IN BOTH A & B MODELS ARE | | | UNDERSIZED- SEE SECTION 601.6 (2) FBC M AND ENLARGE THE | | | GRILLS. | | | | | | 4) M201: CLARIFY THE EXACT LOCATION OF THE NEW | | | CONDENSERS AND PROVIDE INSTALLATION DETAILS- SECTION | | | 301.15 FBC M. | | | | | | 5) M201: PROVIDE CONDENSATE DISPOSAL PLANS FOR THE AIR | | | HANDLERS- SECION 307 FBC M. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2019-01-15 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2019-01-15 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2019-01-15 |
Time |
12:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2018-10-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-10-09 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-10-06 |
Time |
07:10 |
Sent To |
|
|
| Notes |
| 2018-10-09 10:40:44 | 1ST REVIEW: | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | | EDITION | | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | | EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE ENLARGED DETAIL FOR PLUMBING WORK IN THE | | | KITCHENS WITH DIMENSIONS AND CLARIFY THAT THE SINK AND | | | WATER HEATER IS BEING RELOCATED IN TYPE B UNITS IN | | | ORDER TO CLARIFY SCOPE OF PLUMBING WORK. PER WPB AMEND | | | TO FBC 107.2.1 | | | | | | 2. PROVIDE ENLARGED DETAIL FOR PLUMBING WORK IN THE | | | BATHROOMS WITH THE DIMENSIONS SHOWING COMPLIANCE WITH | | | FBC PL 405.3.1 | | | | | | 3. PLEASE CLARIFY WILL THE WATER HEATERS IN THE UNITS | | | BE REPLACED WITH NEW PROVIDE NOTE ON PLAN. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 4. THE WATER HEATER DETAIL IS SHOWING A RECIRCULATION | | | SYSTEM THE WATER ISOMETRIC FOR NEW LAUNDRY IS NOT | | | SHOWING ONE PLEASE CLARIFY ALL PIPING SHALL COMPLY WITH | | | FBCPL 504.6 PIPING FROM T+P VALVE SHALL DISCHARGE | | | THROUGH AIR GAP IN THE SAME ROOM. | | | | | | 5. THE SANITARY STACK FOR THE WASHING MACHINE STAND | | | PIPE SHALL BE VENTED FBC PL 910.1 | | | | | | 6. THE SHUT OFF VALVES FOR THE STACKABLE WASHING | | | MACHINE SHALL BE ACCESSIBLE WITHOUT MOVING THE | | | APPLIANCE. PER FBC PL 606.3 | | | | | | 7. PROVIDE ENLARGED FLOOR PLAN. PER WPB AMEND TO FBC | | | 107.2.1.3 QUALITY OF BUILDING PLANS. BUILDING PLANS | | | SHALL BE DRAWN TO A MINIMUM 1/8 | | | INCH SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER | | | ACCEPTABLE MEDIUM. THE BUILDING | | | OFFICIAL MAY ESTABLISH THROUGH DEPARTMENTAL POLICY, | | | OTHER STANDARDS FOR PLANS AND | | | SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS | | | RECORD RETENTION PROGRAM. THIS POLICY | | | MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE, | | | CONTRAST, CLARITY, OR OTHER ITEMS | | | RELATED TO RECORDS MANAGEMENT. ELECTRONIC MEDIA MUST BE | | | COMPATIBLE WITH THE ARCHIVE | | | REQUIREMENTS OF FLORIDA STATUTES. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2018-12-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2018-12-21 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2018-12-21 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2018-12-21 09:06:11 | ALL NEW DRAWINGS IN DRAWING FOLDER ARE NOT DIGITALLY | | | SIGNED. | | | PLEASE UPLOAD DIGITALLY SIGNED PDF'S. | | | | | | DYLAN BATTLES | | | BUILDING PLANS EXAMINER I | | | [email protected] | | | 561-805-6718 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2018-09-26 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-09-26 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-09-26 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2018-09-26 16:19:14 | ALL SHEETS OK, NEED TO BE CHECKED AT RESUBMITAL FOR ANY | | | NEW SHEETS. FS 471, 481; WPB FBC 107.1 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2018-12-31 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2018-12-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2018-12-31 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2018-09-07 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2018-09-07 |
Time |
|
Rev Time |
|
| Received By |
awooten |
Date |
2018-09-07 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-09-07 15:46:43 | ******************************************************* | | | ********ZONING REVIEW FAILED*************************** | | | ************************* | | | | | | ARE YOU REPLACING THE EXISTING WINDOWS WITH THE SAME | | | TYPE OF WINDOWS? | | | | | | FENCE REPAIR REQUIRES A SEPARATE PERMIT. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | PLANNING DIVISION | | | 561-822-1449 | | | [email protected] |
|
|