Plan Review Details - Permit 18080858
Plan Review Stops For Permit 18080858
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2018-10-23 Cont ID  
Sent By shill Date 2018-10-23 Time 15:27 Rev Time 0.00
Received By shill Date 2018-10-23 Time 15:27 Sent To  
Notes
2018-10-23 15:28:324550 N FLAGLER DR
  

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2018-10-22 Cont ID  
Sent By shill Date 2018-10-22 Time 16:58 Rev Time 0.00
Received By shill Date 2018-10-22 Time 16:58 Sent To  
Notes
2018-10-22 16:59:26****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 PLEASE ADVISE, HAS ADDRESS BEEN CONFIRMED WITH MIKE
 ORIO?
  
 MICHAEL ORIO
 GIS SUPPORT SPECIALIST
 [email protected]
 CITY OF WEST PALM BEACH
 INFORMATION TECHNOLOGY DEPARTMENT
 401 CLEMATIS STREET, WEST PALM BEACH, FLORIDA 33401
 P: 561.494.1080
  
 PLEASE ADVISE WHEN AN ADDRESS HAS BEEN ASSIGNED:
  
 [email protected]
  
  
  
  

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2018-09-22 Cont ID  
Sent By shill Date 2018-09-22 Time 15:31 Rev Time 0.00
Received By shill Date 2018-09-22 Time 15:31 Sent To  
Notes
2018-09-22 15:31:47FOR ADDRESSING, PLEASE CONTACT (PREFERABLY VIA EMAIL):
  
 MICHAEL ORIO
 GIS SUPPORT SPECIALIST
 [email protected]
 CITY OF WEST PALM BEACH
 INFORMATION TECHNOLOGY DEPARTMENT
 401 CLEMATIS STREET, WEST PALM BEACH, FLORIDA 33401
 P: 561.494.1080
  
 PLEASE ADVISE WHEN AN ADDRESS HAS BEEN ASSIGNED:
  
 [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-09-22 Cont ID  
Sent By shill Date 2018-09-22 Time 17:12 Rev Time 0.00
Received By shill Date 2018-09-22 Time 17:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-10-23 Cont ID  
Sent By jpearson Date 2018-10-23 Time 08:17 Rev Time 0.00
Received By jpearson Date 2018-10-23 Time 08:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-09-04 Cont ID  
Sent By jpearson Date 2018-09-04 Time 13:41 Rev Time 0.00
Received By jpearson Date 2018-09-04 Time 13:41 Sent To  
Notes
2018-09-04 13:41:02CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE AIC RATING OF SERVICE DISCONNECT AND PANEL.
 NEC 110.3, 110.9
 2. PROVIDE CALCULATION FOR AVAILABLE SHORT CIRCUIT
 CURRENT AT NEW PANEL TO CONFIRM AIC RATING IS ADEQUATE.
 NEC 110.10
 3. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF
 SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND
 AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24
 4. BE ADVISED THAT THE GENERATOR IS NOT INCLUDED IN THE
 SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE
 INDICATING THE REQUIRED SEPARATE PERMITS AND PLAN
 SUBMITTALS FOR THE GENERATOR. WPB FBC 105.1, 107.2.1
 5. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT
 SERVICE. SHOW ON PLAN. NEC 250.94
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD
 SHEETS?.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2018-09-12 Cont ID  
Sent By RRossano Date 2018-09-12 Time   Rev Time 1.00
Received By rrossano Date 2018-09-12 Time   Sent To I
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-08-23 Cont ID  
Sent By pleduc Date 2018-08-23 Time 16:41 Rev Time 0.00
Received By pleduc Date 2018-08-23 Time 12:11 Sent To  
Notes
2018-08-23 16:41:13THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) COMPLY WITH NFPA 820, NFPA? 820 STANDARD FOR FIRE
 PROTECTION IN WASTEWATER TREATMENT AND COLLECTION
 FACILITIES, 2012 EDITION, WHERE APPLICABLE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-10-23 Cont ID  
Sent By jpearson Date 2018-10-23 Time 08:17 Rev Time 0.00
Received By jpearson Date 2018-10-22 Time 12:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-10-19 Cont ID  
Sent By rcaranci Date 2018-10-19 Time 15:00 Rev Time 0.00
Received By rcaranci Date 2018-08-17 Time 09:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2018-09-13 Cont ID  
Sent By ccole Date 2018-09-13 Time 11:03 Rev Time 0.00
Received By ccole Date 2018-09-13 Time 11:02 Sent To  
Notes
2018-09-13 11:18:14MECH PLANS ARE APPROVED, BUT NOT SIGNED OFF IN PROJECT
 DOX PENDING RECEIPT OF ELECTRONICALLY SIGNED AND SEALED
 PLANS.
 CCOLE- 9/13/18

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2018-10-23 Cont ID  
Sent By jpearson Date 2018-10-23 Time 08:16 Rev Time 0.00
Received By jpearson Date 2018-10-23 Time 08:16 Sent To  
Notes
2018-10-23 08:16:48SEE SIGNATURE FILE FOR DIGITALLY SIGNED PLANS.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2018-09-04 Cont ID  
Sent By jpearson Date 2018-09-04 Time 11:39 Rev Time 0.00
Received By jpearson Date 2018-09-04 Time 11:39 Sent To  
Notes
2018-09-22 17:33:12****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS, FS471.
  
 DO THE ENGINEERS HAVE DIGITAL SIGNATURES? IF YES,
 PLEASE CONTACT ME PRIOR TO RESUBMITTING.
  
 IF NO, AFTER ALL REVIEWS ARE COMPLETE, ONE PAPER
 ORIGINAL IS TO BE SUBMITTED AT THE BUILDING DIVISION
 WITH A "PLAN REVIEW REQUEST FORM". THE DESCRIPTION
 SHOULD BE "SIGNATURE DOCUMENTS".
  
 PLEASE CONTACT ME IF YOU WISH TO DISCUSS.
  
  
  
2018-09-13 11:05:01THE MECHANICAL PLANS ARE NOT ELECTRONICALLY SIGNED AND
 SEALED BY THE ENGINEER OF RECORD- SECTION 61G15-23.005
 FAC.
 CCOLE-9/13/18
2018-09-04 11:39:13PER THE WPB AMENDMENTS TO THE FBC, PLAN (EACH SHEET) IS
 REQUIRED TO BEAR THE NAME AND BE SIGNED AND SEALED BY
 THE PERSON RESPONSIBLE FOR THE DESIGN. PROVIDE
 CORRECTION. WPB FBC 107.1, 107.2; FS 471, 481

Review Stop Z ZONING
Rev No 1 Status P Date 2018-10-19 Cont ID  
Sent By aaponte Date 2018-10-19 Time 14:57 Rev Time 0.00
Received By rcaranci Date 2018-10-19 Time 14:57 Sent To  
Notes
2018-10-19 14:57:49APPROVED PLANS MATCHED. SEPARATE LANDSCAPE PERMIT
 REQUIRED