Plan Review Details - Permit 18080719
Plan Review Stops For Permit 18080719
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-09-14 Cont ID  
Sent By cthroop Date 2018-09-14 Time 11:02 Rev Time 0.00
Received By cthroop Date 2018-09-14 Time 09:50 Sent To E
Notes
2018-09-14 11:06:14PROVISO - PROVIDE WELDER CERTIFICATIONS TO INSPECTOR
 FOR ON-SITE WELDS BETWEEN MODULAR UNIT AND COLUMN WELD
 PLATES. TRAILER HITCH TO BE REMOVED AFTER INSTALLTION.
 CT

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-09-14 Cont ID  
Sent By jleahy Date 2018-09-14 Time 12:15 Rev Time 0.00
Received By jleahy Date 2018-09-14 Time 12:15 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2018-09-20 Cont ID  
Sent By rrossano Date 2018-09-20 Time   Rev Time 0.00
Received By rrossano Date 2018-09-20 Time   Sent To I
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2018-09-12 Cont ID  
Sent By RRossano Date 2018-09-12 Time   Rev Time 1.00
Received By rrossano Date 2018-09-12 Time   Sent To I
Notes
2018-09-12 14:06:10PLEASE ADDRESS ZONING COMMENTS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-08-24 Cont ID  
Sent By scaldero Date 2018-09-18 Time 10:22 Rev Time 0.00
Received By scaldero Date 2018-08-24 Time 10:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-09-20 Cont ID  
Sent By lmarchan Date 2018-09-20 Time 08:41 Rev Time 0.00
Received By lmarchan Date 2018-09-19 Time 11:46 Sent To  
Notes
2018-09-19 11:47:06TO ES DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-09-14 Cont ID  
Sent By jleahy Date 2018-09-14 Time 12:15 Rev Time 0.00
Received By jleahy Date 2018-08-14 Time 10:55 Sent To  
Notes
2018-08-16 10:56:07C12

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2018-09-14 Cont ID  
Sent By cthroop Date 2018-09-14 Time 11:01 Rev Time 0.00
Received By cthroop Date 2018-09-14 Time 09:50 Sent To  
Notes
2018-09-14 11:02:16IMPACT FEES PAID UNDER FOUNDATION PERMIT # 18070612. CT

Review Stop Z ZONING
Rev No 2 Status P Date 2018-09-19 Cont ID  
Sent By eschneid Date 2018-09-19 Time 17:46 Rev Time 0.50
Received By eschneid Date 2018-09-19 Time 17:14 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2018-08-23 Cont ID  
Sent By eschneid Date 2018-08-23 Time 12:06 Rev Time 0.50
Received By eschneid Date 2018-08-23 Time 08:20 Sent To  
Notes
2018-08-23 12:06:04FAILED
  
 1) THE PRESS BOX IS BIGGER, AND DIFFERENT
 ARCHITECTURALLY, TO INCLUDE THE STAIRS, THAN THE ONE
 APPROVED AS PART OF THE KEISER STADIUM AMENDMENT, SO
 PRIOR TO C.O. A MINOR PLANNED DEVELOPMENT AMENDMENT
 SHOWING THE REVISED PRESS BOX IS REQUIRED TO BE
 SUBMITTED TO THE PLANNING DIVISION.
  
 2) THE TRAILER HITCH (SHOWN ON SHEET 2 OF 4) MUST BE
 REMOVED PRIOR TO INSTALLATION. THIS MUST BE CLEARLY
 SHOWN ON THE PLANS.
  
 3) PROVIDE THE HEIGHT OF THE PRESS BOX BUILDING AND THE
 OVERALL HEIGHT OF THE PRESS BOX ON THE SUPPORT POSTS ON
 THE PLANS.
  
 4) PROVIDE INFORMATION AS TO WHERE THE PA SYSTEM WILL
 BE LOCATED. PLEASE REMEMBER THAT THE STADIUM SPEAKERS
 MUST BE INSTALLED TO PROJECT THE SOUND TO THE EAST AND
 INCLUDE A SOUND BAFFLE SYSTEM TO LIMIT WESTWARD SOUND
 PROJECTION.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
 [email protected]